Belden Store
Belden SPE102 0061000 — Datatuff Ind SPE 10Mbps 22AWG SF/UTP PVC

Belden Cable

Belden|

MPN: SPE102 0061000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden SPE102 0061000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: data communications, cameras, PLCs, switches, outdoor, indoor etc.
  • Conductor Size: 22 AWG
  • Conductor Stranding: Stranded
  • Conductor Material: TC - Tinned Copper
  • Conductor No. of Pairs: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nom. Insulation Diameter: 0.067 in (1.7 mm)
  • Insulation Color Code: White & Blue
Belden SPE102 0061000 is an orderable item number in the Belden SPE102 family (Cable › Ethernet Cable › Industrial Ethernet Cable). Datatuff Ind SPE 10Mbps 22AWG PE SF/UTP PVC Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.45 Revision Date: 02-20-2026

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system.

Product Overview

Suitable Applicationsdata communications, cameras, PLCs, switches, outdoor, indoor etc.

Construction Details

Conductor — Size22 AWG
Conductor — MaterialTC - Tinned Copper
Conductor — StrandingStranded
Insulation — MaterialPE - Polyethylene (Foam)
Insulation — Color CodeWhite & Blue
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor — No. Of Pairs1
Outer Jacket — Nom. Diameter0.245 in (6.22 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Outer Shield Row 2 — Coverage90%
Outer Shield Row 2 — MaterialTinned Copper (TC)
Overall Cable Diameter (Nominal).245 in (6.22 mm)
Outer Shield Row 1 — Shield TypeTape
Outer Shield Row 2 — Shield TypeBraid
Insulation — Nom. Insulation Diameter0.067 in (1.7 mm)

Standards And Compliance

APAC ComplianceChina RoHS II (GB/T 26572-2011)
IEEE ComplianceIEEE 802.3cg
TIA/EIA ComplianceANSI/TIA-568.5
NEC / UL ComplianceCM, PLTC
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2022-04-27
Flammability / Reaction To FireUL 1685 UL Loading

Electrical Characteristics

Delay — Frequency100 MHz
Delay — Max. Delay450 ns/100m
Voltage — UL Voltage Rating300 V (UL 13 PLTC)
Delay — Nom. Velocity Of Prop.76%
Electricals — Max. Conductor DCR59 Ohm/km (18 Ohm/1000ft)
Electricals — Max. Mutual Capacitance56 pF/m (17 pF/ft)
High Frequency Row 1 — Frequency [MHz]0.1
High Frequency Row 2 — Frequency [MHz]0.5
High Frequency Row 3 — Frequency [MHz]0.772
High Frequency Row 4 — Frequency [MHz]1
High Frequency Row 5 — Frequency [MHz]2
High Frequency Row 6 — Frequency [MHz]4
High Frequency Row 7 — Frequency [MHz]8
High Frequency Row 8 — Frequency [MHz]10
High Frequency Row 9 — Frequency [MHz]16
High Frequency Row 10 — Frequency [MHz]20
Electricals — Max. Capacitance Unbalance330 pF/100m
High Frequency Row 1 — Min. PSANEXT [DB]67
High Frequency Row 2 — Min. PSANEXT [DB]64.7
High Frequency Row 3 — Min. PSANEXT [DB]61.5
High Frequency Row 4 — Min. PSANEXT [DB]61.4
High Frequency Row 5 — Min. PSANEXT [DB]54.5
High Frequency Row 6 — Min. PSANEXT [DB]49.4
High Frequency Row 7 — Min. PSANEXT [DB]44.3
High Frequency Row 8 — Min. PSANEXT [DB]42.6
High Frequency Row 9 — Min. PSANEXT [DB]39.1
High Frequency Row 10 — Min. PSANEXT [DB]37.5
High Frequency Row 1 — Min. RL (Return Loss) [DB]11.5
High Frequency Row 2 — Min. RL (Return Loss) [DB]15
High Frequency Row 3 — Min. RL (Return Loss) [DB]15
High Frequency Row 4 — Min. RL (Return Loss) [DB]15
High Frequency Row 5 — Min. RL (Return Loss) [DB]15
High Frequency Row 6 — Min. RL (Return Loss) [DB]15
High Frequency Row 7 — Min. RL (Return Loss) [DB]15
High Frequency Row 8 — Min. RL (Return Loss) [DB]15
High Frequency Row 9 — Min. RL (Return Loss) [DB]15
High Frequency Row 10 — Min. RL (Return Loss) [DB]15
High Frequency Row 1 — Min. Coupling Attenuation [DB]50
High Frequency Row 2 — Min. Coupling Attenuation [DB]50
High Frequency Row 3 — Min. Coupling Attenuation [DB]50
High Frequency Row 4 — Min. Coupling Attenuation [DB]50
High Frequency Row 5 — Min. Coupling Attenuation [DB]50
High Frequency Row 6 — Min. Coupling Attenuation [DB]50
High Frequency Row 7 — Min. Coupling Attenuation [DB]50
High Frequency Row 8 — Min. Coupling Attenuation [DB]50
High Frequency Row 9 — Min. Coupling Attenuation [DB]50
High Frequency Row 10 — Min. Coupling Attenuation [DB]50
High Frequency Row 1 — Max. Insertion Loss (Attenuation)1.4 dB/100m
High Frequency Row 2 — Max. Insertion Loss (Attenuation)1.6 dB/100m
High Frequency Row 3 — Max. Insertion Loss (Attenuation)1.9 dB/100m
High Frequency Row 4 — Max. Insertion Loss (Attenuation)2.1 dB/100m
High Frequency Row 5 — Max. Insertion Loss (Attenuation)2.8 dB/100m
High Frequency Row 6 — Max. Insertion Loss (Attenuation)3.8 dB/100m
High Frequency Row 7 — Max. Insertion Loss (Attenuation)5.3 dB/100m
High Frequency Row 8 — Max. Insertion Loss (Attenuation)4.1 dB/100m
High Frequency Row 9 — Max. Insertion Loss (Attenuation)7.5 dB/100m
High Frequency Row 10 — Max. Insertion Loss (Attenuation)8.4 dB/100m
High Frequency Row 1 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 2 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 3 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 4 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 5 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 6 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 7 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 8 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 9 — Nom. Characteristic Impedance [Ohm]100
High Frequency Row 10 — Nom. Characteristic Impedance [Ohm]100

Mechanical Characteristics

Bulk Cable Weight38 lbs/1000ft
Max. Pull Tension10 lbs (4.5 kg)
Temperature — Operating-30°C To +75°C
Temperature — UL Temperature75°C
Bend Radius — Installation Min.2 in (51 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account