Key Features

  • Suitable Applications: 10GX System
Belden RVAXCTM16CBK is an orderable item number in the Belden REVConnect WM Mod. Coupler 16P family (Panels & Patching Systems › Copper Cross-Connect Systems › Category 6A Cross-Connect System). The REVConnect Wall-Mount Termination Module for Couplers has 16-Ports (include 16 cores) This item: Color Black, UPC 611589238397. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.234 Revision Date: 02-03-2025

Standards

UL RatingUL94 V-0, UL1863
IEEE CompliancePower Over Ethernet (PoE) IEEE 802.3at type 1 and 2 (up to 30W), IEEE 802.3bt/D1.7 type 3 and 4 (up to 100W), CISCO UPOE (up to 60W), Power over HDBaseT TM (up to 100W)
TIA/EIA ComplianceCategory 6A - TIA 568.C.2, Category 6A - ISO/IEC 11801:2002 Ed.2

This Item

UPC611589238397
ColorBlack
Item NumberRVAXCTM16CBK

Connectors

Materials Row 1 — ColorBlack
Materials Row 2 — ColorBlack
Materials Row 1 — MaterialLexan
Materials Row 2 — MaterialPlastic
Materials Row 1 — DescriptionFrame
Materials Row 2 — DescriptionCoupler

Product Notes

NotesFor proper installation refer to Installation Guide PX106434 included with the product or visit our web site at http://www.belden.com

Product Overview

Suitable Applications10GX System

Plenum/Non-Plenum

Mated Connection Footnote1* TIA/EIA-568-C.2 Category 6A Standard.
Mated Connection Footnote2** Worst-case performance for a 10GX mated connection using REVConnect Cores.
Mated Connection Row 1 — Frequency (MHz)1.000
Mated Connection Row 2 — Frequency (MHz)4.000
Mated Connection Row 3 — Frequency (MHz)8.000
Mated Connection Row 4 — Frequency (MHz)10.000
Mated Connection Row 5 — Frequency (MHz)16.000
Mated Connection Row 6 — Frequency (MHz)20.000
Mated Connection Row 7 — Frequency (MHz)25.000
Mated Connection Row 8 — Frequency (MHz)31.250
Mated Connection Row 9 — Frequency (MHz)62.500
Mated Connection Row 10 — Frequency (MHz)100.000
Mated Connection Row 11 — Frequency (MHz)200.000
Mated Connection Row 12 — Frequency (MHz)250.000
Mated Connection Row 13 — Frequency (MHz)300.000
Mated Connection Row 14 — Frequency (MHz)400.000
Mated Connection Row 15 — Frequency (MHz)500.000
Mated Connection Row 16 — Frequency (MHz)625.000
Mated Connection Row 1 — Min. FEXT TIA* (DB)75.000 dB
Mated Connection Row 1 — Min. NEXT TIA* (DB)75.000 dB
Mated Connection Row 2 — Min. FEXT TIA* (DB)71.100 dB
Mated Connection Row 2 — Min. NEXT TIA* (DB)75.000 dB
Mated Connection Row 3 — Min. FEXT TIA* (DB)65.000 dB
Mated Connection Row 3 — Min. NEXT TIA* (DB)75.000 dB
Mated Connection Row 4 — Min. FEXT TIA* (DB)63.100 dB
Mated Connection Row 4 — Min. NEXT TIA* (DB)74.000 dB
Mated Connection Row 5 — Min. FEXT TIA* (DB)59.000 dB
Mated Connection Row 5 — Min. NEXT TIA* (DB)69.900 dB
Mated Connection Row 6 — Min. FEXT TIA* (DB)57.100 dB
Mated Connection Row 6 — Min. NEXT TIA* (DB)68.000 dB
Mated Connection Row 7 — Min. FEXT TIA* (DB)55.100 dB
Mated Connection Row 7 — Min. NEXT TIA* (DB)66.000 dB
Mated Connection Row 8 — Min. FEXT TIA* (DB)53.200 dB
Mated Connection Row 8 — Min. NEXT TIA* (DB)64.100 dB
Mated Connection Row 9 — Min. FEXT TIA* (DB)47.200 dB
Mated Connection Row 9 — Min. NEXT TIA* (DB)58.100 dB
Mated Connection Row 10 — Min. FEXT TIA* (DB)43.100 dB
Mated Connection Row 10 — Min. NEXT TIA* (DB)54.000 dB
Mated Connection Row 11 — Min. FEXT TIA* (DB)37.100 dB
Mated Connection Row 11 — Min. NEXT TIA* (DB)48.000 dB
Mated Connection Row 12 — Min. FEXT TIA* (DB)35.100 dB
Mated Connection Row 12 — Min. NEXT TIA* (DB)46.000 dB
Mated Connection Row 13 — Min. FEXT TIA* (DB)33.600 dB
Mated Connection Row 13 — Min. NEXT TIA* (DB)42.900 dB
Mated Connection Row 14 — Min. FEXT TIA* (DB)31.100 dB
Mated Connection Row 14 — Min. NEXT TIA* (DB)37.900 dB
Mated Connection Row 15 — Min. FEXT TIA* (DB)29.100 dB
Mated Connection Row 15 — Min. NEXT TIA* (DB)34.000 dB
Mated Connection Row 1 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 1 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 2 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 2 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 3 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 3 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 4 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 4 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 5 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 5 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 6 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 6 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 7 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 7 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 8 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 8 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 9 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 9 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 1 — Min. FEXT Belden** (DB)80.000 dB
Mated Connection Row 1 — Min. NEXT Belden** (DB)77.000 dB
Mated Connection Row 10 — Min. PSAACRF TIA* (DB)67.000 dB
Mated Connection Row 10 — Min. PSANEXT TIA* (DB)70.500 dB
Mated Connection Row 11 — Min. PSAACRF TIA* (DB)61.000 dB
Mated Connection Row 11 — Min. PSANEXT TIA* (DB)64.500 dB
Mated Connection Row 12 — Min. PSAACRF TIA* (DB)59.000 dB
Mated Connection Row 12 — Min. PSANEXT TIA* (DB)62.500 dB
Mated Connection Row 13 — Min. PSAACRF TIA* (DB)57.500 dB
Mated Connection Row 13 — Min. PSANEXT TIA* (DB)61.000 dB
Mated Connection Row 14 — Min. PSAACRF TIA* (DB)55.000 dB
Mated Connection Row 14 — Min. PSANEXT TIA* (DB)58.500 dB
Mated Connection Row 15 — Min. PSAACRF TIA* (DB)53.000 dB
Mated Connection Row 15 — Min. PSANEXT TIA* (DB)56.500 dB
Mated Connection Row 2 — Min. FEXT Belden** (DB)75.100 dB
Mated Connection Row 2 — Min. NEXT Belden** (DB)77.000 dB
Mated Connection Row 3 — Min. FEXT Belden** (DB)69.000 dB
Mated Connection Row 3 — Min. NEXT Belden** (DB)77.000 dB
Mated Connection Row 4 — Min. FEXT Belden** (DB)67.100 dB
Mated Connection Row 4 — Min. NEXT Belden** (DB)77.000 dB
Mated Connection Row 5 — Min. FEXT Belden** (DB)63.300 dB
Mated Connection Row 5 — Min. NEXT Belden** (DB)72.900 dB
Mated Connection Row 6 — Min. FEXT Belden** (DB)61.100 dB
Mated Connection Row 6 — Min. NEXT Belden** (DB)71.000 dB
Mated Connection Row 7 — Min. FEXT Belden** (DB)59.100 dB
Mated Connection Row 7 — Min. NEXT Belden** (DB)69.000 dB
Mated Connection Row 8 — Min. FEXT Belden** (DB)57.200 dB
Mated Connection Row 8 — Min. NEXT Belden** (DB)67.100 dB
Mated Connection Row 9 — Min. FEXT Belden** (DB)51.200 dB
Mated Connection Row 9 — Min. NEXT Belden** (DB)61.100 dB
Mated Connection Row 10 — Min. FEXT Belden** (DB)47.100 dB
Mated Connection Row 10 — Min. NEXT Belden** (DB)57.000 dB
Mated Connection Row 11 — Min. FEXT Belden** (DB)41.100 dB
Mated Connection Row 11 — Min. NEXT Belden** (DB)51.000 dB
Mated Connection Row 12 — Min. FEXT Belden** (DB)39.100 dB
Mated Connection Row 12 — Min. NEXT Belden** (DB)49.000 dB
Mated Connection Row 13 — Min. FEXT Belden** (DB)37.600 dB
Mated Connection Row 13 — Min. NEXT Belden** (DB)46.700 dB
Mated Connection Row 14 — Min. FEXT Belden** (DB)35.100 dB
Mated Connection Row 14 — Min. NEXT Belden** (DB)42.900 dB
Mated Connection Row 15 — Min. FEXT Belden** (DB)33.100 dB
Mated Connection Row 15 — Min. NEXT Belden** (DB)40.000 dB
Mated Connection Row 16 — Min. FEXT Belden** (DB)31.200 dB
Mated Connection Row 16 — Min. NEXT Belden** (DB)37.100 dB
Mated Connection Row 1 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 1 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 1 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 2 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 2 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 2 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 3 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 3 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 3 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 4 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 4 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 4 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 5 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 5 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 5 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 6 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 6 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 6 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 7 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 7 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 7 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 8 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 8 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 8 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 9 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 9 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 9 — Min. Return Loss TIA* (DB)30.000 dB
Mated Connection Row 1 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 10 — Min. PSAACRF Belden** (DB)72.000 dB
Mated Connection Row 10 — Min. PSANEXT Belden** (DB)72.000 dB
Mated Connection Row 10 — Min. Return Loss TIA* (DB)28.00 dB
Mated Connection Row 11 — Min. PSAACRF Belden** (DB)66.000 dB
Mated Connection Row 11 — Min. PSANEXT Belden** (DB)66.00 dB
Mated Connection Row 11 — Min. Return Loss TIA* (DB)22.000 dB
Mated Connection Row 12 — Min. PSAACRF Belden** (DB)64.000 dB
Mated Connection Row 12 — Min. PSANEXT Belden** (DB)64.00 dB
Mated Connection Row 12 — Min. Return Loss TIA* (DB)20.000 dB
Mated Connection Row 13 — Min. PSAACRF Belden** (DB)62.500 dB
Mated Connection Row 13 — Min. PSANEXT Belden** (DB)62.500 dB
Mated Connection Row 13 — Min. Return Loss TIA* (DB)18.500 dB
Mated Connection Row 14 — Min. PSAACRF Belden** (DB)60.000 dB
Mated Connection Row 14 — Min. PSANEXT Belden** (DB)60.000 dB
Mated Connection Row 14 — Min. Return Loss TIA* (DB)16.000 dB
Mated Connection Row 15 — Min. PSAACRF Belden** (DB)58.000 dB
Mated Connection Row 15 — Min. PSANEXT Belden** (DB)58.000 dB
Mated Connection Row 15 — Min. Return Loss TIA* (DB)14.000 dB
Mated Connection Row 16 — Min. PSAACRF Belden** (DB)56.100 dB
Mated Connection Row 16 — Min. PSANEXT Belden** (DB)56.100 dB
Mated Connection Row 2 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 3 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 4 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 5 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 6 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 7 — Min. Balanced TCL TIA* (DB)40.000 dB
Mated Connection Row 8 — Min. Balanced TCL TIA* (DB)38.100 dB
Mated Connection Row 9 — Min. Balanced TCL TIA* (DB)32.100 dB
Mated Connection Row 10 — Min. Balanced TCL TIA* (DB)28.000 dB
Mated Connection Row 11 — Min. Balanced TCL TIA* (DB)22.000 dB
Mated Connection Row 12 — Min. Balanced TCL TIA* (DB)20.000 dB
Mated Connection Row 13 — Min. Balanced TCL TIA* (DB)18.500 dB
Mated Connection Row 14 — Min. Balanced TCL TIA* (DB)16.000 dB
Mated Connection Row 15 — Min. Balanced TCL TIA* (DB)14.000 dB
Mated Connection Row 1 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 2 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 3 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 4 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 5 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 6 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 7 — Max. Insertion Loss TIA* (DB).100 dB
Mated Connection Row 8 — Max. Insertion Loss TIA* (DB).110 dB
Mated Connection Row 9 — Max. Insertion Loss TIA* (DB).160 dB
Mated Connection Row 10 — Max. Insertion Loss TIA* (DB).200 dB
Mated Connection Row 11 — Max. Insertion Loss TIA* (DB).280 dB
Mated Connection Row 12 — Max. Insertion Loss TIA* (DB).320 dB
Mated Connection Row 13 — Max. Insertion Loss TIA* (DB).350 dB
Mated Connection Row 14 — Max. Insertion Loss TIA* (DB).400 dB
Mated Connection Row 15 — Max. Insertion Loss TIA* (DB).450 dB
Mated Connection Row 1 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 2 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 3 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 4 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 5 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 6 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 7 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 8 — Min. Balanced TCL Belden** (DB)45.000 dB
Mated Connection Row 9 — Min. Balanced TCL Belden** (DB)39.100 dB
Mated Connection Row 10 — Min. Balanced TCL Belden** (DB)35.000 dB
Mated Connection Row 11 — Min. Balanced TCL Belden** (DB)29.000 dB
Mated Connection Row 12 — Min. Balanced TCL Belden** (DB)27.000 dB
Mated Connection Row 13 — Min. Balanced TCL Belden** (DB)25.500 dB
Mated Connection Row 14 — Min. Balanced TCL Belden** (DB)23.000 dB
Mated Connection Row 15 — Min. Balanced TCL Belden** (DB)21.000 dB
Mated Connection Row 16 — Min. Balanced TCL Belden** (DB)19.100 dB
Mated Connection Row 1 — Max. Insertion Loss Belden** (DB).050 dB
Mated Connection Row 2 — Max. Insertion Loss Belden** (DB).050 dB
Mated Connection Row 3 — Max. Insertion Loss Belden** (DB).050 dB
Mated Connection Row 4 — Max. Insertion Loss Belden** (DB).050 dB
Mated Connection Row 5 — Max. Insertion Loss Belden** (DB).060 dB
Mated Connection Row 6 — Max. Insertion Loss Belden** (DB).070 dB
Mated Connection Row 7 — Max. Insertion Loss Belden** (DB).080 dB
Mated Connection Row 8 — Max. Insertion Loss Belden** (DB).090 dB
Mated Connection Row 9 — Max. Insertion Loss Belden** (DB).140 dB
Mated Connection Row 10 — Max. Insertion Loss Belden** (DB).180 dB
Mated Connection Row 11 — Max. Insertion Loss Belden** (DB).260 dB
Mated Connection Row 12 — Max. Insertion Loss Belden** (DB).300 dB
Mated Connection Row 13 — Max. Insertion Loss Belden** (DB).330 dB
Mated Connection Row 14 — Max. Insertion Loss Belden** (DB).380 dB
Mated Connection Row 15 — Max. Insertion Loss Belden** (DB).430 dB
Mated Connection Row 16 — Max. Insertion Loss Belden** (DB).480 dB

Temperature Range

Storage Temperature Range-40°C To +70°C
Installation Temperature Range-10°C To +60°C

Related Part Numbers

Related PartsREVConnect wall termination kit, REVConnect wall connector mount, REVConnect wall cable dressing module, REVConnect cable management channel, REVConnect wall horizontal channel kit
Included Parts16 cores; 1 installation guide

Electrical Characteristics

Current Rating1.500 A
Dielectric Strength1,000 V RMS @ 60 Hz
Insulation Resistance500 M-Ohm Minimum
Termination Resistance2.5 m-Ohm

Mechanical Characteristics

Tool CompatibilityREVConnect Termination Tool (p/n RVUTT01)
Plug/Connector Retention11.250 lbs
Connector/Hardware Retention20 lbs
Termination Interface Row 1 — ConnectionMated Connection
Termination Interface Row 2 — ConnectionMated Connection
Termination Interface Row 1 — TerminationFront
Termination Interface Row 2 — TerminationRear
Termination Interface Row 1 — Durabilities750 cycles
Termination Interface Row 2 — Durabilities20 cycles

Construction And Dimensions

Max Capacity16 Ports

Physical Characteristics (Overall)

Weight0.250 lbs
PackagingIndividually packaged in a box
Overall Depth1.276 in
Overall Width6.794 in
Overall Height2.275 in
Front ConnectionFlush

Flammability, LS0H, Toxicity Testing

Safety Listingc(UL)us Listed

Applicable Environmental And Other Programs

Environmental SpaceIndoor
EU Directive 2002/95/EC RoHSYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account