Key Features
- Suitable Applications: Indoor/Outdoor, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Wet Locations following Product Notes
- Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
- Conductor Size: 23
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor No. of Pairs: 4
- Insulation Material: FEP - Fluorinated Ethylene Propylene
- Insulation Color Code: White & Blue, White & Orange, White & Green, White & Brown
Belden IOP6U 0101000 is an orderable item number in the Belden IOP6U family (Cable › Ethernet Cable › Category 6 Cable). Category 6 Premise Horizontal Cable, Indoor/Outdoor, 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP/CMX Outdoor, Gel Free This item: Color Black, Putup Type Reel, Length 1,000 ft. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.136 Revision Date: 08-04-2026 |
This Item
| Color | Black |
| Length | 1,000 ft |
| Putup Type | Reel |
| Item Number | IOP6U 0101000 |
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Operating temperatures subject to length de-rating. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Suitable for burial or use in outdoor wet locations. Not recommended for Direct Burial applications without additional crush and impact protection. Additional crush and impact protection would include cable armoring, installation in conduit or installation with over top barriers per Belden Technical Bulletin T/8-6. Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation. |
Product Overview
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
| Suitable Applications | Indoor/Outdoor, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Wet Locations following Product Notes |
Construction Details
| Conductor — Size | 23 |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | FEP - Fluorinated Ethylene Propylene |
| Inner Jacket — Ripcord | No |
| Outer Jacket — Ripcord | Yes |
| Inner Jacket — Material | Thermoplastic |
| Insulation — Color Code | White & Blue, White & Orange, White & Green, White & Brown |
| Outer Jacket — Material | PVDF - Polyvinylidene Fluoride |
| Conductor — No. Of Pairs | 4 |
| Inner Jacket — Separator | Barrier Tape |
| Outer Jacket — Separator | Center Member (Patented X-Spline®), EquiBlockTM Barrier Technology |
| Inner Jacket — Nom. Diameter | 0.270 in (6.86 mm) |
| Outer Jacket — Nom. Diameter | 0.27 in (6.9 mm) |
| Overall Cable Diameter (Nominal) | 0.27 in (6.9 mm) |
Standards And Compliance
| Data Category | Category 6 |
| ICEA Compliance | S-116-732 |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| NEMA Compliance | ANSI/NEMA WC-66 |
| CENELEC Compliance | Segregation class according EN50174-2 = a |
| ISO/IEC Compliance | 11801 ed 2.2 (2011) Class EA |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6 |
| NEC / UL Compliance | Article 800, CMP, CMX-Outdoor |
| CEC / C(UL) Compliance | CMP. |
| Environmental Suitability | Indoor/Outdoor, Water Exposure/Below-Grade Conduit, Indoor, Outdoor, Sunlight Resistance |
| European Directive Compliance | REACH |
| Flammability / Reaction To Fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| Third Party Performance Verification | Category 6 |
Electrical Characteristics
| Delay — Frequency | 100 MHz |
| Delay — Max. Delay | 537.6 ns/100m |
| Delay — Max. Delay Skew | 45 ns/100m |
| Voltage — UL Voltage Rating | 300 V (CMP), 300 V (CL3P) |
| Delay — Nom. Velocity Of Prop. | 70% |
| Electricals — Max. Conductor DCR | 82 Ohm/km (25 Ohm/1000ft) |
| High Frequency Row 1 — Min. NEXT [DB] | 74.3 |
| High Frequency Row 2 — Min. NEXT [DB] | 65.3 |
| High Frequency Row 3 — Min. NEXT [DB] | 60.8 |
| High Frequency Row 4 — Min. NEXT [DB] | 59.3 |
| High Frequency Row 5 — Min. NEXT [DB] | 56.2 |
| High Frequency Row 6 — Min. NEXT [DB] | 54.8 |
| High Frequency Row 7 — Min. NEXT [DB] | 53.3 |
| High Frequency Row 8 — Min. NEXT [DB] | 51.9 |
| High Frequency Row 9 — Min. NEXT [DB] | 47.4 |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 10 — Min. NEXT [DB] | 44.3 |
| High Frequency Row 11 — Min. NEXT [DB] | 41.5 |
| High Frequency Row 12 — Min. NEXT [DB] | 39.8 |
| High Frequency Row 13 — Min. NEXT [DB] | 38.3 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 3 — Frequency [MHz] | 8 |
| High Frequency Row 4 — Frequency [MHz] | 10 |
| High Frequency Row 5 — Frequency [MHz] | 16 |
| High Frequency Row 6 — Frequency [MHz] | 20 |
| High Frequency Row 7 — Frequency [MHz] | 25 |
| High Frequency Row 8 — Frequency [MHz] | 31.25 |
| High Frequency Row 9 — Frequency [MHz] | 62.5 |
| High Frequency Row 1 — Min. PSNEXT [DB] | 72.3 |
| High Frequency Row 10 — Frequency [MHz] | 100 |
| High Frequency Row 11 — Frequency [MHz] | 155 |
| High Frequency Row 12 — Frequency [MHz] | 200 |
| High Frequency Row 13 — Frequency [MHz] | 250 |
| High Frequency Row 2 — Min. PSNEXT [DB] | 63.3 |
| High Frequency Row 3 — Min. PSNEXT [DB] | 58.8 |
| High Frequency Row 4 — Min. PSNEXT [DB] | 57.3 |
| High Frequency Row 5 — Min. PSNEXT [DB] | 54.3 |
| High Frequency Row 6 — Min. PSNEXT [DB] | 52.8 |
| High Frequency Row 7 — Min. PSNEXT [DB] | 51.3 |
| High Frequency Row 8 — Min. PSNEXT [DB] | 49.9 |
| High Frequency Row 9 — Min. PSNEXT [DB] | 45.4 |
| Electricals — Max. Capacitance Unbalance | 45 pF/100m |
| High Frequency Row 10 — Min. PSNEXT [DB] | 42.3 |
| High Frequency Row 11 — Min. PSNEXT [DB] | 39.5 |
| High Frequency Row 12 — Min. PSNEXT [DB] | 37.8 |
| High Frequency Row 13 — Min. PSNEXT [DB] | 36.3 |
| High Frequency Row 1 — Min. ACRF (ELFEXT) [DB] | 67.8 |
| High Frequency Row 2 — Min. ACRF (ELFEXT) [DB] | 55.8 |
| High Frequency Row 3 — Min. ACRF (ELFEXT) [DB] | 49.7 |
| High Frequency Row 4 — Min. ACRF (ELFEXT) [DB] | 47.8 |
| High Frequency Row 5 — Min. ACRF (ELFEXT) [DB] | 43.7 |
| High Frequency Row 6 — Min. ACRF (ELFEXT) [DB] | 41.8 |
| High Frequency Row 7 — Min. ACRF (ELFEXT) [DB] | 39.8 |
| High Frequency Row 8 — Min. ACRF (ELFEXT) [DB] | 37.9 |
| High Frequency Row 9 — Min. ACRF (ELFEXT) [DB] | 31.9 |
| High Frequency Row 10 — Min. ACRF (ELFEXT) [DB] | 27.8 |
| High Frequency Row 11 — Min. ACRF (ELFEXT) [DB] | 23.9 |
| High Frequency Row 12 — Min. ACRF (ELFEXT) [DB] | 21.8 |
| High Frequency Row 13 — Min. ACRF (ELFEXT) [DB] | 19.8 |
| High Frequency Row 1 — Min. RL (Return Loss) [DB] | 20 |
| High Frequency Row 2 — Min. RL (Return Loss) [DB] | 23 |
| High Frequency Row 3 — Min. RL (Return Loss) [DB] | 24.5 |
| High Frequency Row 4 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 5 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 6 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 7 — Min. RL (Return Loss) [DB] | 24.3 |
| High Frequency Row 8 — Min. RL (Return Loss) [DB] | 23.6 |
| High Frequency Row 9 — Min. RL (Return Loss) [DB] | 21.5 |
| High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB] | 64.8 |
| High Frequency Row 10 — Min. RL (Return Loss) [DB] | 20.1 |
| High Frequency Row 11 — Min. RL (Return Loss) [DB] | 18.8 |
| High Frequency Row 12 — Min. RL (Return Loss) [DB] | 18 |
| High Frequency Row 13 — Min. RL (Return Loss) [DB] | 17.3 |
| High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB] | 52.7 |
| High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB] | 46.7 |
| High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB] | 44.8 |
| High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB] | 40.7 |
| High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB] | 38.8 |
| High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB] | 36.8 |
| High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB] | 34.9 |
| High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB] | 28.9 |
| High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB] | 24.8 |
| High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB] | 20.9 |
| High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB] | 18.8 |
| High Frequency Row 13 — Min. PSACRF (PSELFEXT) [DB] | 16.8 |
| High Frequency Row 1 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 2 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 3 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 4 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 5 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 6 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 7 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 8 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 9 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 15 |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m] | 2.0 |
| High Frequency Row 10 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 20 |
| High Frequency Row 11 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 20 |
| High Frequency Row 12 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 20 |
| High Frequency Row 13 — Max./Min. Input Impedance (UnFitted) [Ohm] | 100 ± 20 |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m] | 3.8 |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m] | 5.3 |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m] | 6 |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m] | 7.6 |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m] | 8.5 |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m] | 9.5 |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m] | 10.7 |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m] | 15.4 |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m] | 19.8 |
| High Frequency Row 11 — Max. Insertion Loss (Attenuation) [DB/100m] | 25.2 |
| High Frequency Row 12 — Max. Insertion Loss (Attenuation) [DB/100m] | 29.0 |
| High Frequency Row 13 — Max. Insertion Loss (Attenuation) [DB/100m] | 32.8 |
Mechanical Characteristics
| Bulk Cable Weight | 39 lbs/1000ft (58 kg/km) |
| Max. Pull Tension | 25 lbs (11 kg) |
| Temperature — Storage | -40°C To +75°C |
| Temperature — Operating | -40°C To +150°C |
| Temperature — Installation | 0°C To +60°C |
| Temperature — UL Temperature | 150C |
| Bend Radius — Installation Min. | 2.7 in (69 mm) |