- Suitable Applications: For use in railway applications such as rolling stock, buses or other vehicles, cable meets the requirements of the relevant parts of international railway standards like DIN 5510-2, EN 50153, EN 50155, EN 50305 and EN 45545-2, ECE R118.03
- Conductor Size: 24 AWG
- Conductor Stranding: 19x36
- Conductor Material: TC - Tinned Copper
- Conductor No. of Pairs: 4
- Insulation Material: PO - Polyolefin (Foam)
- Insulation Nom. Insulation Diameter: 1.45 mm (0.0571 in)
- Insulation Color Code: White & Blue, White & Orange, White & Green, White & Brown
Belden BE43802 010500M is an orderable item number in the Belden BE43802 family (Cable › Ethernet Cable › Industrial Ethernet Cable). Railtuff ® 7, 4 Pair AWG 24 Tinned Copper - Stranded, XLP/XLPO, XLPE insulation, S/FTP - Overall Braid + Foil shielding,Crosslinked e-beam LSZH / FRNC jacket , EN 45545-2 HL 1-3, ECE R118.03 This item: Color Black, Putup Type Reel, Length 500 m, EAN 6938935091807. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.251 Revision Date: 02-20-2026 |
This Item
| EAN | 6938935091807 |
| Color | Black |
| Length | 500 m |
| Putup Type | Reel |
| Item Number | BE43802 010500M |
Product Overview
| Suitable Applications | For use in railway applications such as rolling stock, buses or other vehicles, cable meets the requirements of the relevant parts of international railway standards like DIN 5510-2, EN 50153, EN 50155, EN 50305 and EN 45545-2, ECE R118.03 |
Construction Details
| Conductor — Size | 24 AWG |
| Insulation — Notes | eBeam Cross-Linked |
| Conductor — Material | TC - Tinned Copper |
| Insulation Table Notes | Insulation OD tolerance +/- 0.05mm |
| Conductor — Stranding | 19x36 |
| Insulation — Material | PO - Polyolefin (Foam) |
| Inner Shield Table Notes | Aluminium facing outside |
| Inner Shield — Element | Individual Shielded Pair |
| Inner Shield — Coverage | 100% |
| Inner Shield — Material | Bi-Laminate (Alum+Poly) |
| Insulation — Color Code | White & Blue, White & Orange, White & Green, White & Brown |
| Outer Jacket — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant, Thermoset) |
| Outer Jacket1 Table Notes | e-Beamed to Cross-link, cable meets smoke test of LU 1-085. Jacket OD +/- 0.3mm |
| Outer Shield — Coverage | 80% |
| Outer Shield — Material | Tinned Copper (TC) |
| Cable Core — Description | 4 pairs twisted together |
| Conductor — No. Of Pairs | 4 |
| Inner Shield — Shield Type | Tape |
| Outer Shield — Shield Type | Braid |
| Outer Jacket — Nom. Diameter | 8.1 mm (0.32 in) |
| Overall Cable Diameter (Nominal) | 8.1 mm (0.32 in) |
| Insulation — Nom. Insulation Diameter | 1.45 mm (0.0571 in) |
Standards And Compliance
| Data Category | Category 7 |
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
| CENELEC Compliance | EN 45545-2, Segregation class according EN50174-2 = d |
| ISO/IEC Compliance | ISO/IEC 11801-1 |
| Environmental Suitability | Indoor, Oil Resistance |
| European Directive Compliance | EU CE Mark |
| European Halogen Free Standards | IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 80% |
| Flammability / Reaction To Fire | IEC 60332-1-2, IEC 60332-2-25, UN ECE R118.03 |
Electrical Characteristics
| Screening Class | Type I |
| Screening Table Notes | Coupling attenuation |
| Transfer Impedance Class | Grade 1 |
| Delay — Max. Delay Skew | 25 ns/100m |
| High Frequency Table Notes | Limits below 4MHz are for information only. Values at 1000 MHz are for information only |
| Voltage — Voltage Rating | 300 V |
| Transfer Impedance Table Notes | IEC 61156-6 |
| Delay — Nom. Velocity Of Prop. | 78% |
| Electricals — Max. Conductor DCR | 95 Ohm/km (29 Ohm/1000ft) |
| Transfer Impedance Row 1 — Frequency | 1 MHz |
| Transfer Impedance Row 2 — Frequency | 10 MHz |
| Transfer Impedance Row 3 — Frequency | 30 MHz |
| Transfer Impedance Row 4 — Frequency | 100 MHz |
| Electricals — Max. Mutual Capacitance | 56 pF/m (17 pF/ft) |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 3 — Frequency [MHz] | 10 |
| High Frequency Row 4 — Frequency [MHz] | 16 |
| High Frequency Row 5 — Frequency [MHz] | 31.2 |
| High Frequency Row 6 — Frequency [MHz] | 62.5 |
| High Frequency Row 7 — Frequency [MHz] | 100 |
| High Frequency Row 8 — Frequency [MHz] | 300 |
| High Frequency Row 9 — Frequency [MHz] | 500 |
| High Frequency Row 10 — Frequency [MHz] | 600 |
| High Frequency Row 11 — Frequency [MHz] | 1000 |
| Electricals — Max. Capacitance Unbalance | 160 pF/100m |
| Electricals — Nom. Characteristic Impedance | 100 Ohm |
| Transfer Impedance Row 1 — Max. Transfer Impedance | Max. 5 mOhm/m |
| Transfer Impedance Row 2 — Max. Transfer Impedance | Max. 5 mOhm/m |
| Transfer Impedance Row 3 — Max. Transfer Impedance | Max. 30 mOhm/m |
| Transfer Impedance Row 4 — Max. Transfer Impedance | 100 mOhm/m |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 2.9 dB/100m |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 5.6 dB/100m |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 8.8 dB/100m |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 11.1 dB/100m |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 15.6 dB/100m |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 22.3 dB/100m |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) | 28.5 dB/100m |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) | 51.3 dB/100m |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) | 67.9 dB/100m |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) | 75.1 dB/100m |
| High Frequency Row 11 — Max. Insertion Loss (Attenuation) | 100.4 dB/100m |
Mechanical Characteristics
| Temperature — Storage | -40°C to +90°C |
| Temperature — Operating | -40°C to +90°C |
| Temperature — Installation | -25°C To +50°C |
| Bend Radius — Stationary Min. | 32 mm (1.3 in) |
| Bend Radius — Installation Min. | 64 mm |