Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9L28309 010100.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors, noisy evnvironments
- Conductor AWG: 28
- Conductor Stranding: 7x36
- Conductor Material: TC - Tinned Copper
- Insulation Material: PVC - Polyvinyl Chloride
- Insulation Nominal Wall Thickness: 0.010 in
- Color Chart Color: Gray
- Outer Shield Type: Tape
Belden 9L28309 010100 is an orderable item number in the Belden 9L28309 family (Cable › Electronic Wire & Cable › Flat Ribbon Cable). Shielded Flat Ribbon Cable .050" Pitch, 9L283XX Series, 9 Conductor, 28 AWG (7x36) Tinned Copper, Gray PVC Insulation, Beldfoil® Tape, Black PVC Jacket This item: Color Black, Put-Up Type Reel, Length 100 ft, UPC 612825221722. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.413 Revision Date: 02-03-2025 |
Standards
| CSA AWM Compliance | II A |
| UL AWM Style Compliance | AWM 20081 |
This Item
| UPC | 612825221722 |
| Color | Black |
| Length | 100 ft |
| Item Number | 9L28309 010100 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
Product Overview
| Suitable Applications | Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors, noisy evnvironments |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Operating Temperature Range | -20°C to +105°C |
Related Part Numbers
| Footnote | E - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'. |
Electrical Characteristics
| Inductance — Element | @ 1 MHz (GSG) with shield grounded |
| Delay — Nominal Delay | 1.7 ns/ft |
| Min Insulation Resistance | 10,000 MOhm |
| Capacitance Row 1 — Element | @ 1 kHz (GSG) with shield grounded |
| Capacitance Row 2 — Element | @ 1 MHz (GSG) with shield grounded |
| Voltage — UL Voltage Rating | 300 V |
| Inductance — Nominal Inductance | 0.11 μH/ft |
| Unbalanced Crosstalk Row 1 — Element | 10 ft. sample length with ground connected to shield |
| Unbalanced Crosstalk Row 2 — Element | 10 ft. sample length with ground connected to shield |
| Unbalanced Crosstalk Row 3 — Element | 10 ft. sample length with ground connected to shield |
| Conductor DCR — Nominal Conductor DCR | 68.2 Ohm/1000ft |
| Current — Max. Recommended Current [A] | 1 Amp per Conductor at 20oC |
| Voltage — Dielectric Withstand Voltage | 2000 V |
| High Frequency Table (Nominal/Typical) Notes | GSG=Ground-Signal-Ground Mode |
| Impedance — Nominal Characteristic Impedance | 45 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 60% |
| Unbalanced Crosstalk Row 1 — Typical Unbalanced FEXT % | 2 |
| Unbalanced Crosstalk Row 1 — Typical Unbalanced NEXT % | 1.5 |
| Unbalanced Crosstalk Row 2 — Typical Unbalanced FEXT % | 1.5 |
| Unbalanced Crosstalk Row 2 — Typical Unbalanced NEXT % | 0.9 |
| Unbalanced Crosstalk Row 3 — Typical Unbalanced FEXT % | 1.2 |
| Unbalanced Crosstalk Row 3 — Typical Unbalanced NEXT % | 0.7 |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 20 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 30 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 40 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 50 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 60 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 70 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 80 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 90 MHz |
| Impedance — Nominal Characteristic Impedance Description | (GSG) with shield grounded |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 100 MHz |
| Capacitance Row 1 — Nom. Capacitance Conductor To Conductor | 70 pF/ft |
| Capacitance Row 2 — Nom. Capacitance Conductor To Conductor | 50 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 6 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 9.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 12.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 14.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 17.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 19 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 21.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 23 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 24.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 26 dB/100ft |
| Unbalanced Crosstalk Row 1 — Typical Cross Talk Pulse Rise Time (Ns) | 3 ns |
| Unbalanced Crosstalk Row 2 — Typical Cross Talk Pulse Rise Time (Ns) | 5 ns |
| Unbalanced Crosstalk Row 3 — Typical Cross Talk Pulse Rise Time (Ns) | 7 ns |
Mechanical Characteristics
| Bulk Cable Weight | 44 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 1.25 in |
| Minimum Bend Radius During Installation | 3.0 in |
Construction And Dimensions
| Conductor Spacing | .050 +/- .002 in |
| OuterJacket1, Nominal Width | .520 in |
| OuterJacket1, Nom Thick Flat Section | 0.115 in |
| Conductor Spacing Center-Center Outside | .400 +/- .008 in |
Physical Characteristics (Overall)
| Conductor Count | 9 |
| Conductor — AWG | 28 |
| Color Chart — Color | Gray |
| Outer Shield — Type | Tape |
| Conductor — Material | TC - Tinned Copper |
| Conductor — Stranding | 7x36 |
| Insulation — Material | PVC - Polyvinyl Chloride |
| Color Chart1 Table Notes | First Conductor has Red Stripe |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield — Material | Bi-Laminate (Alum+Poly) |
| Outer Shield — Coverage [%] | 100% |
| Outer Shield — Drainwire AWG | 28 |
| Outer Shield — Drainwire Material | TC - Tinned Copper |
| Outer Shield — Material Trade Name | Beldfoil® |
| Insulation — Nominal Wall Thickness | 0.010 in |
| Outer Jacket — Nominal Wall Thickness | 0.038 in |
| Outer Shield — Drainwire Construction N X D | 7x36 |
Flammability, LS0H, Toxicity Testing
| UL Flammability | VW-1 |
| UL Voltage Rating | 300 V |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/96/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| CA Prop 65 (CJ For Wire And Cable) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing