Belden Store
Belden 9860 010500 — Twinax 124Ω, 1 Pr #16 Sol BC, PO Ins, OA DF+TC Brd, PVC Jkt, CMX

Belden Cable

Belden|

MPN: 9860 010500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9860 010500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: harsh environment, IIoT, factory or process automation, video, audio, data communication, etc.
  • Conductor AWG: 16
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.051 in
  • Conductor No. of Pairs: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.161 in
Belden 9860 010500 is an orderable item number in the Belden 9860 family (Cable › Fieldbus Cable › Armored Data Cable). Twinax 124Ω, 1 Pair 16AWG (Solid) Bare Copper, PO Insulation, Overall Duofoil®+Tinned Copper Braid(90%) Shield, PVC Outer Jacket, CMX This item: Color Black, Put-Up Type Reel, Length 500 ft, UPC 612825259725. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.488 Revision Date: 02-20-2026

Standards

NEC ArticlesArticle 800
CPR EuroclassEca
NEC/(UL) ComplianceCMX
CEC/C(UL) ComplianceCMX
UL AWM Style ComplianceAWM 2448

This Item

UPC612825259725
ColorBlack
Length500 ft
Item Number9860 010500
Put-Up TypeReel

Product Overview

Suitable Applicationsharsh environment, IIoT, factory or process automation, video, audio, data communication, etc.

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

UL Temperature Rating60°C
Operating Temperature Range-20°C To +60°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Inductance — Element(Loop)
Delay — Nominal Delay1.3 ns/ft
Delay — Max. Delay Skew78 ns/100m
Inductance — Nominal Inductance(Loop) 0.24 μH/ft
Voltage Row 1 — UL Voltage Rating300 V RMS (CM)
Voltage Row 2 — UL Voltage Rating300 V RMS (CMX)
Voltage Row 1 — Voltage Rating [V]AWM style 2448: 30 V RMS
Conductor DCR — Outer Conductor DCR1.3 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR4.2 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]1 MHz
High Frequency Row 2 — Frequency [MHz]10 MHz
High Frequency Row 3 — Frequency [MHz]50 MHz
High Frequency Row 4 — Frequency [MHz]100 MHz
High Frequency Row 5 — Frequency [MHz]200 MHz
High Frequency Row 6 — Frequency [MHz]400 MHz
Conductor DCR — Nominal Outer Shield DCR1.3 Ohm/1000ft
Impedance — Nominal Characteristic Impedance124 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]78%
Capacitance — Nom. Capacitance Conductor To Shield10.9 pF/ft
Capacitance — Nom. Capacitance Conductor To Conductor10.9 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.2 dB/100m
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.7 dB/100m
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss1.8 dB/100m
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss2.9 dB/100m
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss4.1 dB/100m
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss6.2 dB/100m
Capacitance — Nom. Capacitance Conductor To Other Conductor To Shield19.3 pF/ft

Mechanical Characteristics

Bulk Cable Weight98 lbs/1000ft
Minimum Minor Axis Bend Radius4.5 in
Maximum Recommended Pulling Tension73 lbs

Construction And Dimensions

Stranding — Diameter0.322 mm

Physical Characteristics (Overall)

Conductor Count2
Conductor — AWG16
Color Chart — ColorBlue & Clear
Color Chart — Number1
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor — No. Of Pairs1
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.051 in
Insulation — Nominal Diameter0.161 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialTinned Copper (TC)
Outer Jacket — Nominal Diameter0.44 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]90%
Outer Jacket — Nominal Wall Thickness0.045 in
Outer Shield Row 1 — Material Trade NameDuofoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityVW-1
UL Voltage Rating300 V RMS (CM)

Applicable Environmental And Other Programs

EU CE MarkYes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account