
Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9844LS.011000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, ...); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.
- Conductor Element: Pair(s)
- Conductor No. of Elements: 4
- Conductor Size: 24 AWG
- Conductor Stranding: 7x32
- Conductor Material: TC - Tinned Copper
- Insulation Element: Pair(s)
- Insulation Material: PE - Polyethylene
Belden 9844LS.011000 is an orderable item number in the Belden 9844LS family (Cable › Fieldbus Cable › Armored Data Cable). RS-485, 4 Pair AWG 24 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil + Braid(s) shielding, LSZH / FRNC jacket , 300V, SWA This item: Color Black, Putup Type Reel, Length 1,000 m, EAN 8719605023421. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.249 Revision Date: 07-23-2026 |
This Item
| EAN | 8719605023421 |
| Color | Black |
| Length | 1,000 m |
| Putup Type | Reel |
| Item Number | 9844LS.011000 |
Product Overview
| Suitable Applications | RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, ...); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
Construction Details
| Armor — Coverage | Min. 95% |
| Conductor — Size | 24 AWG |
| Conductor — Element | Pair(s) |
| Conductor — Material | TC - Tinned Copper |
| Insulation — Element | Pair(s) |
| Conductor — Stranding | 7x32 |
| Insulation — Material | PE - Polyethylene |
| Armor — Armor Thickness | 1.25 mm |
| Inner Jacket — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Insulation — Color Code | White/Blue & Blue/White, White/Orange & Orange/White, White/Green & Green/White, White/Brown & Brown/White |
| Outer Jacket — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Conductor — No. Of Elements | 4 |
| Insulation — Nom. Thickness | 0.56 mm (0.022 in) |
| Inner Jacket — Nom. Diameter | 9.9 mm (0.39 in) |
| Outer Jacket — Nom. Diameter | 15.1 mm (0.594 in) |
| Armor — Armor Type & Material | SWA - Steel Wire Armor |
| Inner Jacket — Nom. Thickness | 0.89 mm (0.035 in) |
| Outer Jacket — Nom. Thickness | 1.35 mm (0.0531 in) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Outer Shield Row 2 — Coverage | 90% |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Overall Cable Diameter (Nominal) | 15.1 mm (0.594 in) |
| Outer Shield Row 1 — Shield Type | Tape |
| Outer Shield Row 2 — Shield Type | Braid |
| Outer Shield Row 1 — Drainwire Type | 24 AWG (7x32) TC |
| Insulation — Nom. Insulation Diameter | 1.73 mm (0.0681 in) |
Standards And Compliance
| CENELEC Compliance | EN 50290-2-20 |
| UK Regulation Compliance | UKCA Mark |
| Environmental Suitability | Indoor Indoor/Outdoor Outdoor, Indoor, Outdoor, Non-Halogenated, Sunlight Resistance, Oil Resistance - IRM 902 70°Cx4h, Oil Resistance - IEC 60811-404 |
| Other Standard Compliance(s) | DMX-512 |
| European Directive Compliance | EU CE Mark |
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60% |
| Flammability / Reaction To Fire | IEC 60332-3-24 |
Electrical Characteristics
| Nom Outer Shield DCR | 6.9 Ohm/km (2.1 Ohm/1000ft) |
| Electricals — Element | Pair(s) |
| Electricals — Nom. Delay | 5.2 ns/m |
| Voltage — Voltage Rating | 300 V |
| Electricals — Max. Current | 2.1 Amps per Conductor |
| Electricals — Nom. Conductor DCR | 78.7 Ohm/km (24.0 Ohm/1000ft) |
| Electricals — Nom. Velocity Of Prop. | 66% |
| High Frequency (Nominal/Typical) — Element | Pair(s) |
| Electricals — Nom. Capacitance Cond-to-Cond | 42 pF/m (13 pF/ft) |
| Electricals — Nom. Characteristic Impedence | 120 Ohm |
| High Frequency (Nominal/Typical) — Frequency [MHz] | 1 |
| Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield) | 75.5 pF/m (23.0 pF/ft) |
| High Frequency (Nominal/Typical) — Nom. Insertion Loss (Attenuation) [DB/100m] | 1.97 |
Mechanical Characteristics
| Bulk Cable Weight | 426 kg/km (286 lbs/1000ft) |
| Max. Pull Tension | 500 N (110 lbf) |
| Temperature — Storage | -45°C To +80°C |
| Temperature — Operating | -45°C To +80°C |
| Temperature — Installation | -15°C To +80°C |
| Bend Radius — Stationary Min. | 100 mm (3.9 in) |
| Bend Radius — Installation Min. | 151 mm (5.94 in) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing