Key Features
- Suitable Applications: RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, ...); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.
- Conductor Element: Pair(s)
- Conductor No. of Elements: 3
- Conductor Size: 24 AWG
- Conductor Stranding: 7x32
- Conductor Material: TC - Tinned Copper
- Insulation Element: Pair(s)
- Insulation Material: PE - Polyethylene
Belden 9843LS.00500 is an orderable item number in the Belden 9843LS family (Cable › Ethernet Cable › Industrial Ethernet Cable). RS-485, 3 Pair AWG 24 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil + Braid(s) shielding, LSZH / FRNC jacket , 300V, SWA This item: Color Black, Putup Type Reel, Length 500 m, EAN 8719605127235. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.230 Revision Date: 07-23-2026 |
This Item
| EAN | 8719605127235 |
| Color | Black |
| Length | 500 m |
| Putup Type | Reel |
| Item Number | 9843LS.00500 |
Product Overview
| Suitable Applications | RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, ...); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc. |
Construction Details
| Armor — Coverage | Min. 95% |
| Conductor — Size | 24 AWG |
| Conductor — Element | Pair(s) |
| Conductor — Material | TC - Tinned Copper |
| Insulation — Element | Pair(s) |
| Conductor — Stranding | 7x32 |
| Insulation — Material | PE - Polyethylene |
| Armor — Armor Thickness | 0.9 mm |
| Inner Jacket — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Insulation — Color Code | White/Blue & Blue/White, White/Orange & Orange/White, White/Green & Green/White |
| Outer Jacket — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Conductor — No. Of Elements | 3 |
| Insulation — Nom. Thickness | 0.56 mm (0.022 in) |
| Inner Jacket — Nom. Diameter | 9.1 mm (0.36 in) |
| Outer Jacket — Nom. Diameter | 13.5 mm (0.531 in) |
| Armor — Armor Type & Material | SWA - Steel Wire Armor |
| Inner Jacket — Nom. Thickness | 0.9 mm (0.035 in) |
| Outer Jacket — Nom. Thickness | 1.3 mm (0.051 in) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Outer Shield Row 2 — Coverage | 90% |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Overall Cable Diameter (Nominal) | 13.5 mm (0.531 in) |
| Outer Shield Row 1 — Shield Type | Tape |
| Outer Shield Row 2 — Shield Type | Braid |
| Outer Shield Row 1 — Drainwire Type | 24 AWG (7x32) TC |
| Insulation — Nom. Insulation Diameter | 1.73 mm (0.0681 in) |
Standards And Compliance
| CPR Compliance | CPR Euroclass: Eca |
| CENELEC Compliance | EN 50290-2-20 |
| UK Regulation Compliance | UKCA Mark |
| Environmental Suitability | Indoor Indoor/Outdoor Outdoor Indoor/Outdoor - Euroclass Eca, Indoor, Outdoor, Non-Halogenated, Sunlight Resistance, Oil Resistance - IRM 902 70°Cx4h, Oil Resistance - IEC 60811-404 |
| Other Standard Compliance(s) | DMX-512 |
| European Directive Compliance | EU CE Mark |
| European Halogen Free Standards | IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60% |
| Flammability / Reaction To Fire | IEC 60332-3-24, IEC 60332-1-2 |
Electrical Characteristics
| Nom Outer Shield DCR | 7.2 Ohm/km (2.2 Ohm/1000ft) |
| Electricals — Element | Pair(s) |
| Electricals — Nom. Delay | 5.2 ns/m |
| Voltage — Voltage Rating | 300 V |
| Electricals — Max. Current | 2.1 Amps per Conductor |
| Electricals — Nom. Conductor DCR | 78.7 Ohm/km (24.0 Ohm/1000ft) |
| Electricals — Nom. Velocity Of Prop. | 66% |
| High Frequency (Nominal/Typical) — Element | Pair(s) |
| Electricals — Nom. Capacitance Cond-to-Cond | 42 pF/m (13 pF/ft) |
| Electricals — Nom. Characteristic Impedence | 120 Ohm |
| High Frequency (Nominal/Typical) — Frequency [MHz] | 1 |
| Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield) | 75.5 pF/m (23.0 pF/ft) |
| High Frequency (Nominal/Typical) — Nom. Insertion Loss (Attenuation) [DB/100m] | 1.97 |
Mechanical Characteristics
| Bulk Cable Weight | 324 kg/km (218 lbs/1000ft) |
| Max. Pull Tension | 500 N (110 lbf) |
| Temperature — Storage | -45°C To +80°C |
| Temperature — Operating | -45°C To +80°C |
| Temperature — Installation | -15°C To +80°C |
| Bend Radius — Stationary Min. | 133 mm (5.24 in) |
| Bend Radius — Installation Min. | 202.5 mm (7.972 in) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing