Key Features

  • Conductor AWG: 14
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.064 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.28 in
  • Outer Jacket Material: PE - Polyethylene
Belden 9764 0101000 is an orderable item number in the Belden 9764 family (Cable › Video Cable › CATV Cable). CATV, Series 11, 14 AWG solid .064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond Plus®; aluminum braid shield (75% coverage), polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825258452. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.383 Revision Date: 02-20-2026

Standards

RG Type11
Series Type11

This Item

UPC612825258452
ColorBlack
Length1,000 ft
Item Number9764 0101000
Put-Up TypeReel

Suitability

Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating80°C
Operating Temperature Range-55°C To +80°C

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Return Loss — Frequency [MHz]5-1000 MHz
Inductance — Nominal Inductance0.097 μH/ft
Voltage — Non-UL Voltage Rating300 V RMS
Conductor DCR — Outer Conductor DCR3.8 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR11 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]5 MHz
High Frequency Row 2 — Frequency [MHz]55 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]270 MHz
High Frequency Row 5 — Frequency [MHz]300 MHz
High Frequency Row 6 — Frequency [MHz]350 MHz
High Frequency Row 7 — Frequency [MHz]400 MHz
High Frequency Row 8 — Frequency [MHz]450 MHz
High Frequency Row 9 — Frequency [MHz]550 MHz
High Frequency Row 10 — Frequency [MHz]750 MHz
High Frequency Row 11 — Frequency [MHz]870 MHz
High Frequency Row 12 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Outer Shield DCR3.8 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Return Loss — Min. Structural Return Loss (SRL)20 dB
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.38 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)0.96 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)1.9 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)2.13 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)2.25 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)2.42 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)2.6 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)2.75 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)3.04 dB/100ft
High Frequency Row 10 — Max. Insertion Loss (Attenuation)3.65 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)4.06 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)4.35 dB/100ft

Mechanical Characteristics

Bulk Cable Weight52 lbs/1000ft
Minimum Minor Axis Bend Radius4 in
Maximum Recommended Pulling Tension276 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG14
Conductor — MaterialBCCS - Bare Copper Covered Steel
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Shield Table NotesTape has shorting fold and is bonded to jacket
Conductor — No. Of Coax1
Outer Jacket — MaterialPE - Polyethylene
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 3 — TypeTape
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Outer Shield Row 3 — Layer3
Conductor — Nominal Diameter0.064 in
Insulation — Nominal Diameter0.28 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Shield Row 3 — MaterialBi-Laminate (Alum+Poly)
Outer Jacket — Nominal Diameter0.4 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]75%
Outer Shield Row 3 — Coverage [%]100%
Outer Shield Row 1 — Material Trade NameDuobond® II

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceOutdoor - Water Exposure
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account