Belden 9729LS.001000 — RS-232/422, 2PR #24 Str TC, PO ins, IF, LSZH Jkt, 300V, SWA

Belden Cable

Belden|

MPN: 9729LS.001000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9729LS.001000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Instrumentation and computer cable; For data transmission applications
  • Conductor Size: 24
  • Conductor Stranding: 7x32
  • Conductor Material: TC - Tinned Copper
  • Inner Shield Shield Type: Tape
  • Inner Shield Material: Bi-Laminate (Alum+Poly)
  • Outer Shield Material: Bi-Laminate (Alum+Poly)
  • Inner Jacket Material: LSZH - Low Smoke Zero Halogen (Flame Retardant)
Belden 9729LS.001000 is an orderable item number in the Belden 9729LS family (Cable › Electronic Wire & Cable › Multi-Conductor Cable). RS-232/422, 2 Pair AWG 24 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Individually Foiled + No Overall shielding, LSZH / FRNC jacket , 300V, SWA This item: Color Black, Putup Type Reel, Length 1,000 m, EAN 8719605022509. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.250 Revision Date: 07-23-2026

This Item

EAN8719605022509
ColorBlack
Length1,000 m
Putup TypeReel
Item Number9729LS.001000

Product Overview

Suitable ApplicationsInstrumentation and computer cable; For data transmission applications

Construction Details

Armor — CoverageMin. 95%
Conductor — Size24
Conductor — MaterialTC - Tinned Copper
Inner Jacket — ColorChrome (RAL 7037)
Conductor — Stranding7x32
Armor — Armor Thickness0.9 mm
Inner Jacket — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Inner Shield — MaterialBi-Laminate (Alum+Poly)
Outer Jacket — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Outer Shield — MaterialBi-Laminate (Alum+Poly)
Inner Shield — Shield TypeTape
Insulation Row 1 — MaterialPE - Polyethylene (Foam)
Inner Jacket — Nom. Diameter7.9 mm (0.31 in)
Outer Jacket — Nom. Diameter12.5 mm (0.492 in)
Armor — Armor Type & MaterialSWA - Steel Wire Armor
Insulation Row 1 — Color CodeBlack & Red, Black & White
Insulation Row 2 — Color CodeRed, Green
Outer Jacket — Nom. Thickness1.35 mm (0.0531 in)
Insulation Row 1 — Nom. Insulation Diameter1.55 mm (0.0610 in)

Standards And Compliance

CENELEC ComplianceEN 50290-2-20
Environmental SuitabilityIndoor Indoor/Outdoor Outdoor Indoor/Outdoor - Euroclass Eca, Sunlight Resistance, Oil Resistance - IRM 902 70°Cx4h, Oil Resistance - IEC 60811-404
European Halogen Free StandardsIEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 2.5 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60%
Flammability / Reaction To FireIEC 60332-3-24

Electrical Characteristics

Electricals — Max. Current1 A
Electricals — Nom. Conductor DCR78.7 Ohm/km (24.0 Ohm/1000ft)
Electricals — Nom. Inner Shield DCR59.1 Ohm/km (18.0 Ohm/1000ft)
Electricals — Nom. Capacitance Cond-to-Cond41 pF/m (12 pF/ft)
Electricals — Nom. Characteristic Impedence100 Ohm
High Frequency (Nominal/Typical) Row 1 — Frequency2 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency3 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency4 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency5 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency6 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency11 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency12 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency24 MHz
Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield)76.1 pF/m (23.2 pF/ft)
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss (Attenuation) [DB/100m]4.63
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss (Attenuation) [DB/100m]5.35
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss (Attenuation) [DB/100m]5.91
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss (Attenuation) [DB/100m]6.5
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss (Attenuation) [DB/100m]6.89
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss (Attenuation) [DB/100m]9.15
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss (Attenuation) [DB/100m]9.51
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss (Attenuation) [DB/100m]13.16

Mechanical Characteristics

Temperature — Storage-45°C To +80°C
Temperature — Installation-15°C To +80°C
Bend Radius — Installation Min.187.5 mm (7.382 in)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account