Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9659 010U500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Conductor AWG: 22
- Conductor Stranding: 7x30
- Conductor Material: BC - Bare Copper
- Conductor Nominal Diameter: 0.03 in
- Conductor No. of Coax: 1
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nominal Diameter: 0.146 in
- Outer Shield Type: Braid
Belden 9659 010U500 is an orderable item number in the Belden 9659 family (Cable › Video Cable › Coaxial Video Cable). 22 AWG stranded (7x30) .030" bare copper conductor, foam polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket. This item: Color Black, Put-Up Type UnReel, Length 500 ft, UPC 612825414728. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.334 Revision Date: 02-20-2026 |
Standards
| RG Type | 59 |
| Series Type | 59 |
| NEC/(UL) Compliance | CMX |
| CEC/C(UL) Compliance | CMX |
| UL AWM Style Compliance | AWM 1354 (30 V 60°C) |
This Item
| UPC | 612825414728 |
| Color | Black |
| Length | 500 ft |
| Item Number | 9659 010U500 |
| Put-Up Type | UnReel |
Suitability
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
Product Notes
| Notes | For CCTV Applications. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Operating Temperature Range | -40°C To +80°C |
Electrical Characteristics
| Delay — Nominal Delay | 1.3 ns/ft |
| Voltage — UL Voltage Rating | 150 V RMS |
| Return Loss — Frequency [MHz] | 5-450 MHz |
| Inductance — Nominal Inductance | 0.09 μH/ft |
| Voltage — Non-UL Voltage Rating | 300 V RMS |
| Return Loss — Minimum Return (RL) | 23 dB |
| Conductor DCR — Outer Conductor DCR | 2.6 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 15 Ohm/1000ft |
| Conductor DCR — Nominal Outer Shield DCR | 2.6 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 75 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 78% |
| Capacitance — Nom. Capacitance Conductor To Shield | 17.3 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 50 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 100 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 200 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 400 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 700 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 900 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 1000 MHz |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 15 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.3 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 0.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 2.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 3 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 4.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 6.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 8.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 10.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 10.9 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 35 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 2.5 in |
| Maximum Recommended Pulling Tension | 65 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 22 |
| Outer Shield — Type | Braid |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | 7x30 |
| Insulation — Material | PE - Polyethylene (Foam) |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride (Non-Contaminating) |
| Outer Shield — Material | Bare Copper (BC) |
| Outer Shield — Coverage [%] | 95% |
| Conductor — Nominal Diameter | 0.03 in |
| Insulation — Nominal Diameter | 0.146 in |
| Outer Jacket — Nominal Diameter | 0.242 in |
Flammability, LS0H, Toxicity Testing
| UL Flammability | VW-1 |
| CSA Flammability | FT1 |
| UL Voltage Rating | 150 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| Environmental Space | Indoor/Outdoor |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |