Belden Store
Belden 9571 002U500 — Electronic, 2 C #18 Sol BC, PVC Ins, Red PVC Jkt, FPLR

Belden Cable

Belden|

MPN: 9571 002U500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9571 002U500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: fire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, ...)
  • Conductor Element: Conductor(s)
  • Conductor No. of Elements: 2
  • Conductor Size: 18 AWG
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Insulation Element: Conductor(s)
  • Insulation Material: PVC - Polyvinyl Chloride
Belden 9571 002U500 is an orderable item number in the Belden 9571 family (Cable › Electronic Wire & Cable › Multi-Conductor Cable). Electronic, 2 Conductor 18AWG (Solid) Bare Copper, PVC Insulation, Red PVC Outer Jacket, FPLR This item: Color Red, UPC 612825256090. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.395 Revision Date: 02-20-2026

This Item

UPC612825256090
ColorRed
Item Number9571 002U500

Product Overview

Suitable Applicationsfire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, ...)

Construction Details

Conductor — Size18 AWG
Conductor — ElementConductor(s)
Conductor — MaterialBC - Bare Copper
Insulation — ElementConductor(s)
Conductor — StrandingSolid
Insulation — MaterialPVC - Polyvinyl Chloride
Insulation — Color CodeBlack, Red
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialNo Shield
Conductor — No. Of Elements2
Insulation — Nom. Thickness0.017 in (0.43 mm)
Outer Jacket — Nom. Diameter0.228 in
Outer Jacket — Nom. Thickness0.037 in (0.94 mm)
Overall Cable Diameter (Nominal)0.228 in
Insulation — Nom. Insulation Diameter0.072 in mm

Standards And Compliance

AWM ComplianceAWM 2464
CPR ComplianceCPR Euroclass: Eca
APAC ComplianceChina RoHS II (GB/T 26572-2011)
NEC / UL ComplianceArticle 760, Article 800, CMR, FPLR
CEC / C(UL) ComplianceFAS105.
UK Regulation ComplianceUKCA Mark
European Directive ComplianceEU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL 1666 riser, FT4

Electrical Characteristics

Electricals — Max. Current5.2 Amps per Conductor at 25oC
Voltage — UL Voltage Rating300 V
Electricals — Nom. Inductance0.169 μH/ft (0.554 μH/m)
Electricals — Nom. Conductor DCR6.3 Ohm/1000ft
Electricals — Nom. Capacitance Cond-to-Cond22 pF/ft (72 pF/m)

Mechanical Characteristics

Bulk Cable Weight26 lbs/1000ft
Max. Pull Tension39.2 lbs (17.8 kg)
Temperature — Operating-40°C To +105°C
Temperature — UL Temperature105°C
Bend Radius — Stationary Min.2.28 in (57.9 mm)
Bend Radius — Installation Min.2.28 in

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account