Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9486 0101000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control
- Conductor Element: Pair(s)
- Conductor No. of Elements: 1
- Conductor Size: 18
- Conductor Stranding: 19x30
- Conductor Material: TC - Tinned Copper
- Insulation Material: PVC/Nylon - Polyvinyl Chloride + Nylon
- Insulation Nom. Thickness: 0.016 in (0.41 mm)
Belden 9486 0101000 is an orderable item number in the Belden 9486 family (Cable › Tray & TC Cable). High Performance Instrumentation, 1 Pair 18AWG (19x32) Tinned Copper, PVC-NYL Insulation E2 Color Code, Black PVC Outer Jacket, 600V TC This item: Color Black, UPC 612825253778, Footnote C. Ships from and sold by A5 IT. Quoted to order.
History
| Footnote | C - CRATE REEL PUT-UP. |
| Update And Revision | Revision Number: 0.587 Revision Date: 09-07-2025 |
This Item
| UPC | 612825253778 |
| Color | Black |
| Footnote | C |
| Item Number | 9486 0101000 |
Product Notes
| Notes | Alternate color coding available upon request. |
Product Overview
| Suitable Applications | Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, ...), encoders, control circuits, distributed control |
Construction Details
| Conductor — Size | 18 |
| Conductor — Element | Pair(s) |
| Conductor — Material | TC - Tinned Copper |
| Conductor — Stranding | 19x30 |
| Insulation — Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Outer Jacket — Ripcord | Yes |
| Insulation — Color Code | Black & Red |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor — No. Of Elements | 1 |
| Insulation — Nom. Thickness | 0.016 in (0.41 mm) |
| Outer Jacket — Nom. Diameter | 0.275 in (6.99 mm) |
| Outer Jacket — Nom. Thickness | 0.048 in (1.2 mm) |
| Insulation — Nom. Insulation Diameter | 0.088 in (2.2 mm) |
Standards And Compliance
| CPR Compliance | CPR Euroclass: Eca |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| NEC / UL Compliance | Article 336, Article 760, NPLF, TC |
| UK Regulation Compliance | UKCA Mark |
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Burial |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL 1685 UL loading, IEEE 1202 FT4 |
Electrical Characteristics
| Electricals — Max. Current | 15 Amps per Conductor at 25oC |
| Voltage — UL Voltage Rating | 600 V (TC), 150 V (NPLF) |
| Electricals — Nom. Inductance | 0.23 μH/ft (0.75 μH/m) |
| Electricals — Nom. Conductor DCR | 7.29 Ohm/1000ft |
Mechanical Characteristics
| Bulk Cable Weight | 40 lbs/1000ft |
| Max. Pull Tension | 50 lbs (23 kg) |
| Temperature — Operating | Wet/Dry: -30°C to 90°C |
| Temperature — UL Temperature | 90°C Dry, 90°C Wet |
| Bend Radius — Stationary Min. | 1.08 in (27.4 mm) |
| Bend Radius — Installation Min. | 1.35 in (34.3 mm) |