Belden 935023006 is an orderable item number in the Belden 0980 SSL 3030-121-007D-101 family (I/O Systems › Safety I/O Modules). LioN-Safety 16/8-F-DI M12 PROFINET / PROFIsafe , M12 L-coded Power Supply, Metal 60mm, IoT Protocols (OPC UA, MQTT, CoAP, REST) This item: Item Description 0980 SSL 3030-121-007D-101. Ships from and sold by A5 IT. Quoted to order.
Notes
| Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
Safety
| Mission Time | 20 years |
| Safety Reaction Time | 42ms |
| Safety Digital Inputs | 16/8 |
| Category Cat. (ISO 13849) | up to 4 |
| Performance Level IL (ISO 13849) | up to e |
| SIL/ SIL CL (IEC 62061/ IEC 61508) | up to 3 |
| Probability Of Failure Per Hour (PFH) | 1,25 E-9 - DC avg. 99,41% (F-DI dual-channel); 5,25 E-9 - DC avg. 98,55% (F-DI single-channel) |
EtherCAT
| CoAP | Cyclic data read/write, Diagnosis data, Event data |
| MQTT | Cyclic data read/write, Diagnosis data, Event data |
| OPC UA | Cyclic data read/write, Diagnosis data, Event data |
| REST API | Cyclic data read/write, Diagnosis data, Event data |
PROFINET
| Protocol | PROFINET |
| Addressing | DCP |
| Connection | M12 LAN, 4-poles, D-coded |
| Shared Input | not supported |
| Netload Class | III |
| Shared Device | Supported |
| Specification | V2.44 |
| Conformance Class | C (CC-C) |
| Performance Class | RT (switch supports IRT) |
| Transmission Rate | Fast Ethernet (10/100 Mbit/s), Full Duplex |
| Topology Detection | LLDP, SNMP V3 |
| Transmission Method | 100 BASE-TX, with auto negotiation and auto crossing |
| Safety Communication | PROFIsafe (V2.6.1) |
| Number Of Connections | 2 |
| Easy Device Replacement | Supported, based on LLDP |
| Cycle Time / Update Rate | min. 1 ms |
| Media Redundancy Protocol (MRP) | Supported, MRP client |
| Supported Network Protocols (Other) | ARP, HTTP, Ping, SNMP V1, TCP/IP |
Approvals
| UL | cULus Listed, UL 61010-1 |
| CSA | Yes, via UL |
| PNO | Yes |
| IO-Link | Yes |
| FS-Certification | TÜV (Rheinland) IEC 61508, ISO 13849 |
This Item
| Item Number | 935023006 |
| Item Description | 0980 SSL 3030-121-007D-101 |
Information
| I/O Type | Functional Safety Digital Input |
| Device Type | FS I/O Device |
| I/O Function | 16/8 FS DI |
| Bus Connection | M12 LAN, 4-poles, D-coded |
| I/O Connection | M12, 5-poles, A-coded |
| Product Family | I/O Systems: Active - Standalone |
| Item Description | 0980 SSL 3030-121-007D-101 |
| Protocol Compatibility | PROFISAFE |
| Power Supply Connection | M12 Power, 5-poles, L-coded |
| Side 1 Product Sub Family | LioN-Safety |
| Protection Degree / IP Rating Note | *only if mounted and locked in combination with Hirschmann / Lumberg Automation connector. |
| System Power Supply Connection Note | *do not connect / disconnect under voltage! |
General Data
| Potted | Yes |
| Weight | approx. 500 g |
| Mount Type | 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts. |
| Housing Color | Grey Metallic |
| Housing Plating | Nickel, matt |
| O-Ring Material | FKM |
| Housing Material | Metal, Zinc Die-cast |
| Protection Class | III, IEC 61140, EN 61140, VDE 0140-1 |
| Shock Resistance | 50 g / 11ms |
| Flammabilty Class | UL 94 (IEC 61010) |
| Included In Delivery | Attachable Labels: 15x, Sealing Caps: 5x M12 |
| Vibration Resistance | 15 g / 5 -500 Hz |
| Contact Base Material | M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated |
| Dimensions (W X H X D) | 60 mm x 31 mm x 200 mm |
| Contact Bearer Material | PA |
| Side 1 Pollution Degree | 3 acc. to EN 60664-1, VDE 0110-1 |
| Air Pressure (Operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Mean Time To Failure (MTTF) | 106 years |
| Fastening Torque (Fixing Screw) | M4: 1 Nm |
| Protection Degree / IP Rating** | IP65, IP67, IP69K |
| Air Pressure (Storage/Transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Ambient Temperature (Operation)* | 0 °C to +40 °C (HW: 03, 30, 40) / -40 °C to +70 °C (HW: 50) |
| Permissible Humidity (Operation) | 5 % ... 98 % (For UL applications max. 80 %) |
| Fastening Torque (Bus Connection) | M12: 0.5 Nm |
| Fastening Torque (I/O Connection) | M12: 0.5 Nm |
| Fastening Torque (Power Connection) | M12: 0.5 Nm |
| Ambient Temperature (Storage/Transport) | -40 °C to 85 °C |
| Permissible Humidity (Storage/Transport) | 5 % ... 98 % (For UL applications max. 80 %) |
| Fastening Torque (Ground Connection (FE)) | M4: 1 Nm |
Power Supply
| Diagnostic Indicator | LED red |
| Number Of Connections | 2 |
| Current Consumption (Typ.) | typ. 180mA (at 24 V DC) |
| Reverse Polarity Protection | Yes |
| Module Supply Voltage (Range) | 18 V DC to 30 V DC |
| Sensor Supply Voltage (Range) | 18 V DC to 30 V DC |
| Actuator Supply Voltage (Range) | 18 V DC to 30 V DC |
| Module Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
| Sensor Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
| Connection Module Supply Voltage | M12 Power, 5-poles, L-coded |
| Connection Sensor Supply Voltage | M12 Power, 5-poles, L-coded |
| Status Indicator (Sensor Supply) | LED green |
| Status Indicator (System Supply) | LED green |
| Actuator Supply Voltage (Nominal) | 24 V DC (SELV/PELV) |
| Status Indicator (Actuator Supply) | LED green |
| Current Carrying Capacity Of Connector | max. 16 A |
EMC Conformance
| EMC Directive | 2014/30/EU |
| EN 61000-4-5 Surge Voltage | Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m |
| EN 61000-4-6 Conducted Immunity | Criterion A; Test voltage 10 V |
| EN 61000-4-3 Electromagnetic Field | Criterion A; Field intensity: 10 V/m |
| EN 61000-4-4 Fast Transients (Burst) | Criterion A, 1 kV; Criterion DS, 2 kV |
| EN 55022 Radio Interference Properties | Class A |
| EN 55032 Radio Interference Properties | Class A |
| EN 61000-4-2 Electrostatic Discharge (ESD) | Criterion B; 4 kV contact discharge, 8 kV air discharge |
Electrical Isolation
| US (System Supply Voltage) / FE | 32V DC (clamp voltage) |
Analog Output Channels
| UL / FE | 32V DC (clamp voltage) |
| Bus Connection / FE | 2000 V DC |
| US / UL (Actuator Supply Voltage) | 500 V DC |
Digital Input Channels
| Connection | M12, 5-poles, A-coded |
| Sensor Type | P-switching; Type 3 for DI configurations “Without Test Pulse” and Potential-free switches for DI configurations “With Test Pulse” |
| Channel Type | Type 3 acc. to IEC 61131-2 |
| Input Wiring | 2-, 3-, 4-wire |
| Nominal Current | typ. 3 mA |
| Nominal Voltage | 24 V DC via US (module power supply) |
| Number Of Ports | 8x, X1 to X8 |
| Protective Circuit | Electronicaly: Overload protection, short-circuit protection |
| Diagnostic Indicator | LED white or yellow per channel |
| Sensor Current Supply | max. 1500 mA per port |
| Input Voltage Range "0" Signal | -3 V DC ...+5 V DC |
| Input Voltage Range "1" Signal | 11 V DC ... 30 V DC |
| Number Of Digital Input Channels | up to 16 |
Safety & Environmental Compliance
| CE | Yes |
| RoHS Compliant | Yes |
| China RoHS-Compliant | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing