Belden Store
Belden 9232 0101000 — Video Triax, RG11, #15 Stranded, CSPE Jacket

Belden Cable

Belden|

MPN: 9232 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9232 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor Size: 15
  • Conductor Stranding: 19x27
  • Conductor Nom. Diameter: 0.064 in
  • Conductor Material: BC - Bare Copper
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nom. Insulation Diameter: 0.312 in (7.92 mm)
  • Inner Shield Shield Type: Braid
  • Inner Shield Material: Bare Copper (BC)
Belden 9232 0101000 is an orderable item number in the Belden 9232 family (Cable › Broadcast Cable › Video Triax Cable). 15 AWG stranded (19x27) .064" bare copper conductor, foam HDPE insulation, paper tape separator, bare copper braid shields (90% and 80% coverage), CSPE - Chlorosulphonated Polyethylene jacket. This item: Color Black, Putup Type Reel, Length 1,000 ft, UPC 612825356042, Footnote C. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP.
Update And RevisionRevision Number: 0.401 Revision Date: 07-30-2026

This Item

UPC612825356042
ColorBlack
Length1,000 ft
FootnoteC
Putup TypeReel
Item Number9232 0101000

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured
Discontinuation Announcement Date2022-07-13

Construction Details

RG Type11
Conductor — Size15
Conductor — MaterialBC - Bare Copper
Insulation Table NotesGas Injected
Conductor — Stranding19x27
Insulation — MaterialPE - Polyethylene (Foam)
Outer Shield Table NotesPaper Tape
Inner Jacket — MaterialPE - Polyethylene
Inner Shield — Coverage90%
Inner Shield — MaterialBare Copper (BC)
Outer Jacket — MaterialCSPE - Chlorosulphonated Polyethylene
Outer Shield — Coverage80%
Outer Shield — MaterialBare Copper (BC)
Conductor — Nom. Diameter0.064 in
Inner Shield — Shield TypeBraid
Inner Jacket — Nom. Diameter0.391 in (9.93 mm)
Outer Jacket — Nom. Diameter0.52 in
Outer Shield — Outer Shield TypeBraid
Insulation — Nom. Insulation Diameter0.312 in (7.92 mm)

Standards And Compliance

AWM ComplianceAWM 1641 (30 V 60°C)
CPR ComplianceCPR Euroclass: Eca
APAC ComplianceChina RoHS II (GB/T 26572-2011)
UK Regulation ComplianceUKCA Mark
Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Aerial - When supported by messenger wire, Burial
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireVW-1, UL2556

Electrical Characteristics

Return Loss — Frequency5-450 MHz
Voltage — Voltage Rating300 V RMS
Voltage — UL Voltage Rating30 V RMS
Attenuation Row 1 — Frequency1 MHz
Attenuation Row 2 — Frequency3.6 MHz
Attenuation Row 3 — Frequency10 MHz
Attenuation Row 4 — Frequency71.5 MHz
Attenuation Row 5 — Frequency135 MHz
Attenuation Row 6 — Frequency270 MHz
Attenuation Row 7 — Frequency360 MHz
Attenuation Row 8 — Frequency540 MHz
Attenuation Row 9 — Frequency720 MHz
Attenuation Row 10 — Frequency750 MHz
Attenuation Row 11 — Frequency1000 MHz
Electrical Characteristics NotesNominal Capacitance 1st Shield to 2nd Shield: 205 pf/ft.
Return Loss — Min. Return Loss21 dB
Electricals — Nom. Conductor DCR3.1 Ohm/1000ft (10 Ohm/km)
Electricals — Nom. Inner Shield DCR1.6 Ohm/1000ft (5.2 Ohm/km)
Electricals — Nom. Outer Shield DCR1.6 Ohm/1000ft (5.2 Ohm/km)
Attenuation Row 1 — Nom. Attenuation0.1 dB/100ft
Attenuation Row 2 — Nom. Attenuation0.3 dB/100ft
Attenuation Row 3 — Nom. Attenuation0.5 dB/100ft
Attenuation Row 4 — Nom. Attenuation1.2 dB/100ft
Attenuation Row 5 — Nom. Attenuation1.8 dB/100ft
Attenuation Row 6 — Nom. Attenuation2.6 dB/100ft
Attenuation Row 7 — Nom. Attenuation3.1 dB/100ft
Attenuation Row 8 — Nom. Attenuation3.9 dB/100ft
Attenuation Row 9 — Nom. Attenuation4.7 dB/100ft
Electricals — Nom. Velocity Of Prop.78%
Attenuation Row 10 — Nom. Attenuation4.8 dB/100ft
Attenuation Row 11 — Nom. Attenuation5.7 dB/100ft
Electricals — Nom. Characteristic Impedance75 Ohm
Electricals — Nom. Capacitance Cond-to-Shield17.3 pF/ft (56.8 pF/m)

Mechanical Characteristics

Bulk Cable Weight135 lbs/1000ft (201 kg/km)
Max. Pull Tension239 lbs (108 kg)
Temperature — Operating-20°C To +75°C
Temperature — UL Temperature60°C

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account