Belden Store
Belden 9117M 0101000 — CATV Video, RG6, 18 AWG BCCS, Messenger

Belden Cable

Belden|

MPN: 9117M 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 9117M 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.18 in
  • Outer Jacket Material: PVC - Polyvinyl Chloride
Belden 9117M 0101000 is an orderable item number in the Belden 9117M family (Cable › Video Cable › CATV Cable). Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II, aluminum braid shield (60% coverage), PVC jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825224594. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.384 Revision Date: 02-20-2026

Standards

RG Type6
Series Type6

This Item

UPC612825224594
ColorBlack
Length1,000 ft
Item Number9117M 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Operating Temperature Range-40°C To +80°C

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Return Loss — Frequency [MHz]5-1000 MHz
Inductance — Nominal Inductance0.097 μH/ft
Voltage — Non-UL Voltage Rating350 V RMS
Conductor DCR — Outer Conductor DCR9 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR28 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]5 MHz
High Frequency Row 2 — Frequency [MHz]55 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]270 MHz
High Frequency Row 5 — Frequency [MHz]300 MHz
High Frequency Row 6 — Frequency [MHz]350 MHz
High Frequency Row 7 — Frequency [MHz]400 MHz
High Frequency Row 8 — Frequency [MHz]450 MHz
High Frequency Row 9 — Frequency [MHz]550 MHz
High Frequency Row 10 — Frequency [MHz]750 MHz
High Frequency Row 11 — Frequency [MHz]870 MHz
High Frequency Row 12 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Outer Shield DCR9 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Return Loss — Min. Structural Return Loss (SRL)20 dB
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.58 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)1.60 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)3.05 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)3.37 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)3.55 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)3.85 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)4.15 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)4.40 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)4.90 dB/100ft
High Frequency Row 10 — Max. Insertion Loss (Attenuation)5.65 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)6.11 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)6.55 dB/100ft

Mechanical Characteristics

Bulk Cable Weight42 lbs/1000ft
Minimum Minor Axis Bend Radius2.75 in
Maximum Recommended Pulling Tension110 lbs

Construction And Dimensions

OuterJacket1, Messenger Diameter0.051 in
OuterJacket1, Messenger MaterialGalvanized Steel

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Conductor — MaterialBCCS - Bare Copper Covered Steel
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.18 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Jacket — Nominal Diameter0.27 x 0.41 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 1 — Material Trade NameDuofoil®

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceOutdoor - Aerial
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account