Key Features

  • Conductor AWG: 14
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.064 in
  • Conductor No. of Coax: 1
  • Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
  • Insulation Nominal Diameter: 0.274 in
  • Outer Jacket Material: FEP - Fluorinated Ethylene Propylene
Belden 89292 0101000 is an orderable item number in the Belden 89292 family (Cable › Video Cable › Coaxial Video Cable). 14 AWG solid .064" bare copper conductor, plenum, foam FEP insulation, Duofoil®; tinned copper braid shield (65% coverage), FEP jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825220923. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.358 Revision Date: 02-20-2026

Standards

RG Type11
NEC/(UL) ComplianceCATVP, CMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825220923
ColorBlack
Length1,000 ft
Item Number89292 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes

Product Notes

NotesTeflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

Non-UL Temp Rating200°C
Operating Temperature Range-70°C To +200°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.
Non-Plenum Number9292

Electrical Characteristics

Delay — Nominal Delay1.22 ns/ft
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.091 μH/ft
Conductor DCR — Outer Conductor DCR3 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR2.5 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR3 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]450 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance2.5 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.2 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.4 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss1 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss1.5 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss2.2 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss3.3 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss4.5 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss5.2 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss5.5 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Nom. Structural Return Loss (SRL)23 dB

Mechanical Characteristics

Bulk Cable Weight73 lbs/1000ft
Minimum Minor Axis Bend Radius4 in
Maximum Recommended Pulling Tension97 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG14
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialFEP - Fluorinated Ethylene Propylene
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.064 in
Insulation — Nominal Diameter0.274 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialTinned Copper (TC)
Outer Jacket — Nominal Diameter0.346 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]65%
Outer Jacket — Material Trade NameTeflon®
Outer Shield Row 1 — Material Trade NameDuofoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
Environmental SpaceIndoor - Plenum
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account