Key Features
- Conductor AWG: 19
- Conductor Stranding: Solid
- Conductor Material: SCCS - Silvered Copper Covered Steel
- Conductor Nominal Diameter: 0.037 in
- Conductor No. of Coax: 1
- Insulation Material: PTFE - Polytetrafluoroethylene
- Insulation Material Trade Name: Teflon®
- Insulation Nominal Diameter: 0.116 in
Belden 84303 0011000 is an orderable item number in the Belden 84303 family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). RG-303/U, 19 AWG solid .037" silver-coated copper-covered steel conductor, plenum, TFE insulation, silver-coated copper braid shield (95% coverage), FEP jacket, commercial non-QPL product. This item: Color Brown, Put-Up Type Reel, Length 1,000 ft, UPC 612825206996. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.363 Revision Date: 02-20-2026 |
Standards
| RG Type | 303 |
| Military Compliance | Commercial, non-QPL product (M17/111-RG303) |
| NEC/(UL) Compliance | CL2P |
| Qualified Products List | No |
This Item
| UPC | 612825206996 |
| Color | Brown |
| Length | 1,000 ft |
| Item Number | 84303 0011000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Aerial | Yes - When supported by messenger wire |
| Suitability - Burial | No |
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Hazardous Locations | No |
| Suitability - Sunlight Resistance | No |
Plenum/Non-Plenum
| Plenum (Y/N) | Yes |
Temperature Range
| UL Temperature Rating | 200°C |
| Operating Temperature Range | -70°C To +200°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP., E - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'. |
Electrical Characteristics
| VSWR — Max. VSWR | per M17/111-RG303 |
| Delay — Nominal Delay | 1.46 ns/ft |
| Voltage — Description | MIL |
| VSWR — Frequency [MHz] | 50 MHz - 1000 MHz |
| Voltage — UL Voltage Rating | 150 V RMS |
| Voltage — Voltage Rating [V] | 1400 V RMS (Mil Spec) |
| Inductance — Nominal Inductance | 0.067 μH/ft |
| Conductor DCR — Outer Conductor DCR | 4.3 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 16.3 Ohm/1000ft |
| High Frequency Row 1 — Frequency [MHz] | 50 MHz |
| High Frequency Row 2 — Frequency [MHz] | 400 MHz |
| High Frequency Row 3 — Frequency [MHz] | 1000 MHz |
| High Frequency Row 4 — Frequency [MHz] | 3000 MHz |
| Conductor DCR — Nominal Outer Shield DCR | 4.3 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 50 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 70% |
| Capacitance — Nom. Capacitance Conductor To Shield | 29 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 50 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 100 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 200 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 400 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 700 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 900 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 1000 MHz |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 2.7 dB/100ft |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 8.6 dB/100ft |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 15 dB/100ft |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 28 dB/100ft |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 16.3 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.3 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 1.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 2.7 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 3.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 5.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 8.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 11 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 12.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 13.5 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 30 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 2 in |
| Maximum Recommended Pulling Tension | 112 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 19 |
| Outer Shield — Type | Braid |
| Conductor — Material | SCCS - Silvered Copper Covered Steel |
| Outer Shield — Layer | 1 |
| Conductor — Stranding | Solid |
| Insulation — Material | PTFE - Polytetrafluoroethylene |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | FEP - Fluorinated Ethylene Propylene |
| Outer Shield — Material | Silvered Copper (SC) |
| Outer Shield — Coverage [%] | 95% |
| Conductor — Nominal Diameter | 0.037 in |
| Insulation — Nominal Diameter | 0.116 in |
| Outer Jacket — Nominal Diameter | 0.17 in |
| Insulation — Material Trade Name | Teflon® |
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
| CSA Flammability | FT6 |
| UL Voltage Rating | 150 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | No |
| Environmental Space | Outdoor - Aerial |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |