Belden Store
Belden 84303 0011000 — 50 Ohm Coax, RG303, 19 AWG Solid SCCCS, SCC Braid, FEP Jacket, CL2P

Belden Cable

Belden|

MPN: 84303 0011000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 84303 0011000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 19
  • Conductor Stranding: Solid
  • Conductor Material: SCCS - Silvered Copper Covered Steel
  • Conductor Nominal Diameter: 0.037 in
  • Conductor No. of Coax: 1
  • Insulation Material: PTFE - Polytetrafluoroethylene
  • Insulation Material Trade Name: Teflon®
  • Insulation Nominal Diameter: 0.116 in
Belden 84303 0011000 is an orderable item number in the Belden 84303 family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). RG-303/U, 19 AWG solid .037" silver-coated copper-covered steel conductor, plenum, TFE insulation, silver-coated copper braid shield (95% coverage), FEP jacket, commercial non-QPL product. This item: Color Brown, Put-Up Type Reel, Length 1,000 ft, UPC 612825206996. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.363 Revision Date: 02-20-2026

Standards

RG Type303
Military ComplianceCommercial, non-QPL product (M17/111-RG303)
NEC/(UL) ComplianceCL2P
Qualified Products ListNo

This Item

UPC612825206996
ColorBrown
Length1,000 ft
Item Number84303 0011000
Put-Up TypeReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - BurialNo
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Hazardous LocationsNo
Suitability - Sunlight ResistanceNo

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

UL Temperature Rating200°C
Operating Temperature Range-70°C To +200°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP., E - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25'.

Electrical Characteristics

VSWR — Max. VSWRper M17/111-RG303
Delay — Nominal Delay1.46 ns/ft
Voltage — DescriptionMIL
VSWR — Frequency [MHz]50 MHz - 1000 MHz
Voltage — UL Voltage Rating150 V RMS
Voltage — Voltage Rating [V]1400 V RMS (Mil Spec)
Inductance — Nominal Inductance0.067 μH/ft
Conductor DCR — Outer Conductor DCR4.3 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR16.3 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]50 MHz
High Frequency Row 2 — Frequency [MHz]400 MHz
High Frequency Row 3 — Frequency [MHz]1000 MHz
High Frequency Row 4 — Frequency [MHz]3000 MHz
Conductor DCR — Nominal Outer Shield DCR4.3 Ohm/1000ft
Impedance — Nominal Characteristic Impedance50 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]70%
Capacitance — Nom. Capacitance Conductor To Shield29 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1000 MHz
High Frequency Row 1 — Max. Insertion Loss (Attenuation)2.7 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)8.6 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)15 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)28 dB/100ft
Conductor DCR — Nominal Conductor DCR Conductor Resistance16.3 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.3 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss1.1 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss2.7 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss3.9 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss5.6 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss8.2 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss11 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss12.5 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss13.5 dB/100ft

Mechanical Characteristics

Bulk Cable Weight30 lbs/1000ft
Minimum Minor Axis Bend Radius2 in
Maximum Recommended Pulling Tension112 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG19
Outer Shield — TypeBraid
Conductor — MaterialSCCS - Silvered Copper Covered Steel
Outer Shield — Layer1
Conductor — StrandingSolid
Insulation — MaterialPTFE - Polytetrafluoroethylene
Conductor — No. Of Coax1
Outer Jacket — MaterialFEP - Fluorinated Ethylene Propylene
Outer Shield — MaterialSilvered Copper (SC)
Outer Shield — Coverage [%]95%
Conductor — Nominal Diameter0.037 in
Insulation — Nominal Diameter0.116 in
Outer Jacket — Nominal Diameter0.17 in
Insulation — Material Trade NameTeflon®

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
CSA FlammabilityFT6
UL Voltage Rating150 V RMS

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceOutdoor - Aerial
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account