Belden Store
Belden 8281F J5C500 — 75 Ohm Analog Video Coax, RG-59, 21 AWG Str BC, Double 95% TC Braid, PVC Jkt. Flexible

Belden Cable

Belden|

MPN: 8281F J5C500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 8281F J5C500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Standard analog video
  • Conductor Size: 21 AWG
  • Conductor Stranding: 7x29
  • Conductor Nom. Diameter: 0.032 in
  • Conductor Material: BC-C - Bare Copper (Compacted)
  • Insulation Material: PE - Polyethylene
  • Insulation Nom. Insulation Diameter: 0.193 in (4.90 mm)
  • Insulation Color Code: White
Belden 8281F J5C500 is an orderable item number in the Belden 8281F family (Cable › Broadcast Cable › SDI Video Coax Cable). 75 Ohm Analog Video Coax, RG-59, 21 AWG (7x29) Bare Copper (Compacted) Conductor , PE Insulation, Double 95% Tinned Copper Braid Shield, PVC Jacket, Flexible This item: Color Black, Vivid Matte, Putup Type Reel, Length 500 ft, UPC 612825355465. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP.
Update And RevisionRevision Number: 0.480 Revision Date: 02-20-2026

This Item

UPC612825355465
ColorBlack, Vivid Matte
Length500 ft
Putup TypeReel
Item Number8281F J5C500

Product Notes

NotesCompacted copper combines the Impedance uniformity of solid conductors and the ""nick-resistance"" of stranded conductors.

Product Overview

Suitable ApplicationsStandard analog video

Construction Details

RG Type59
Conductor — Size21 AWG
Conductor — MaterialBC-C - Bare Copper (Compacted)
Conductor — Stranding7x29
Insulation — MaterialPE - Polyethylene
Insulation — Color CodeWhite
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor — Nom. Diameter0.032 in
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Outer Jacket — Nom. Diameter0.304 in (7.72 mm)
Outer Shield Row 1 — Coverage95%
Outer Shield Row 1 — MaterialTinned Copper (TC)
Outer Shield Row 2 — Coverage95%
Outer Shield Row 2 — MaterialTinned Copper (TC)
Overall Cable Diameter (Nominal)0.304 in (7.72 mm)
Insulation — Nom. Insulation Diameter0.193 in (4.90 mm)
Outer Shield Row 1 — Outer Shield TypeBraid
Outer Shield Row 2 — Outer Shield TypeBraid

Standards And Compliance

CPR ComplianceCPR Euroclass: Eca
SustainabilityCA Prop 65
APAC ComplianceChina RoHS II (GB/T 26572-2011)
UK Regulation ComplianceUKCA Mark
Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger wire
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

Electrical Characteristics

Voltage — Voltage Rating2900 V
Attenuation Row 1 — Frequency1 MHz
Attenuation Row 2 — Frequency3.6 MHz
Attenuation Row 3 — Frequency10 MHz
Attenuation Row 4 — Frequency71.5 MHz
Attenuation Row 5 — Frequency135 MHz
Attenuation Row 6 — Frequency270 MHz
Attenuation Row 7 — Frequency360 MHz
Attenuation Row 8 — Frequency540 MHz
Attenuation Row 9 — Frequency720 MHz
Return Loss Row 1 — Frequency2 - 216 MHz
Return Loss Row 2 — Frequency217 - 830 MHz
Attenuation Row 10 — Frequency750 MHz
Attenuation Row 11 — Frequency1000 MHz
Electricals — Nom. Conductor DCR11.6 Ohm/1000ft
Electricals — Nom. Outer Shield DCR1.7 Ohm/1000ft (5.6 Ohm/km)
Attenuation Row 1 — Nom. Attenuation0.3 dB/100ft
Attenuation Row 2 — Nom. Attenuation0.5 dB/100ft
Attenuation Row 3 — Nom. Attenuation0.9 dB/100ft
Attenuation Row 4 — Nom. Attenuation2.5 dB/100ft
Attenuation Row 5 — Nom. Attenuation3.6 dB/100ft
Attenuation Row 6 — Nom. Attenuation5.1 dB/100ft
Attenuation Row 7 — Nom. Attenuation6 dB/100ft
Attenuation Row 8 — Nom. Attenuation7.4 dB/100ft
Attenuation Row 9 — Nom. Attenuation8.7 dB/100ft
Electricals — Nom. Velocity Of Prop.66%
Return Loss Row 1 — Min. Return Loss27 dB
Return Loss Row 2 — Min. Return Loss23 dB
Attenuation Row 10 — Nom. Attenuation8.9 dB/100ft
Attenuation Row 11 — Nom. Attenuation10.5 dB/100ft
Electricals — Nom. Characteristic Impedance75 Ohm
Electricals — Nom. Capacitance Cond-to-Shield20.5 pF/ft (67.3 pF/m)

Mechanical Characteristics

Bulk Cable Weight61 lbs/1000ft
Max. Pull Tension168 lbs (76.2 kg)
Temperature — Operating-20°C to +60°C
Bend Radius — Installation Min.3.0 in (76 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account