Belden Store
Belden 8241A 0101000 — Analog Video, RG59, #23 Solid BCCS, 95% BC Braid, PVC Jacket, CMG

Belden Cable

Belden|

MPN: 8241A 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 8241A 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 23
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.023 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.146 in
  • Outer Shield Type: Braid
Belden 8241A 0101000 is an orderable item number in the Belden 8241A family (Cable › Coax & Triax Cable › CCTV & Security Cable). 23 AWG solid .023" bare copper-covered steel conductor, flame-retardant semi-foam Polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825355984. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.342 Revision Date: 02-20-2026

Standards

RG Type59
NEC/(UL) ComplianceCMG
CEC/C(UL) ComplianceCMG
UL AWM Style ComplianceAWM 1354 (30 V 75°C)

This Item

UPC612825355984
ColorBlack
Length1,000 ft
Item Number8241A 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes
Suitability - OutdoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range-40°C To +75°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.54 ns/ft
Voltage — UL Voltage Rating300 V RMS
Voltage — Voltage Rating [V]30 V RMS
Electrical Characteristics Notes30 V RMS (UL AWM Style 1354); 300 V RMS
Inductance — Nominal Inductance0.112 μH/ft
Conductor DCR — Outer Conductor DCR2.6 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR49 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR2.6 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]66%
Capacitance — Nom. Capacitance Conductor To Shield20.5 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance49 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.6 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.9 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss1.1 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss2.4 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss3.4 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss4.9 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss7 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss10.1 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss11.7 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss13.2 dB/100ft

Mechanical Characteristics

Bulk Cable Weight39 lbs/1000ft
Minimum Minor Axis Bend Radius2.5 in
Maximum Recommended Pulling Tension74 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG23
Outer Shield — TypeBraid
Conductor — MaterialBCCS - Bare Copper Covered Steel
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialBare Copper (BC)
Outer Shield — Coverage [%]95%
Conductor — Nominal Diameter0.023 in
Insulation — Nominal Diameter0.146 in
Outer Jacket — Nominal Diameter0.242 in

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 FT4 Loading
CSA FlammabilityFT4
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor (Not Riser or Plenum)
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account