Key Features

  • Conductor AWG: 20
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.032 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.145 in
  • Inner Shield Type: Braid
Belden 8232 010500 is an orderable item number in the Belden 8232 family (Cable › Broadcast Cable › Video Triax Cable). 20 AWG solid .032" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shields (95% and 80% coverage), polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 500 ft, UPC 612825355663. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.334 Revision Date: 02-20-2026

Standards

RG Type59

This Item

UPC612825355663
ColorBlack
Length500 ft
Item Number8232 010500
Put-Up TypeReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes

Plenum/Non-Plenum

Plenum (Y/N)No
Plenum Number88232

Temperature Range

Non-UL Temp Rating80°C
Operating Temperature Range-55°C To +80°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.22 ns/ft
Inductance — Nominal Inductance0.097 μH/ft
Voltage — Non-UL Voltage Rating300 V RMS
Return Loss Row 1 — Frequency [MHz]5-850 MHz
Return Loss Row 2 — Frequency [MHz]850-3000 MHz
Conductor DCR — Nominal Conductor DCR10 Ohm/1000ft
Conductor DCR — Nominal Inner Shield DCR2.5 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR2.8 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
Return Loss Row 1 — Min. Structural Return Loss (SRL)21 dB
Return Loss Row 2 — Min. Structural Return Loss (SRL)15 dB
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]3.6 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]71.5 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]135 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]270 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]360 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]540 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]720 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]750 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 12 — Frequency [MHz]1500 MHz
High Frequency (Nominal/Typical) Row 13 — Frequency [MHz]2250 MHz
High Frequency (Nominal/Typical) Row 14 — Frequency [MHz]3000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance10 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.3 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.6 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.9 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss2.1 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss3 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss4.2 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss4.8 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss5.9 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss7 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss7.1 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss8.3 dB/100ft
High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss10.5 dB/100ft
High Frequency (Nominal/Typical) Row 13 — Nom. Insertion Loss13.4 dB/100ft
High Frequency (Nominal/Typical) Row 14 — Nom. Insertion Loss15.9 dB/100ft

Mechanical Characteristics

Bulk Cable Weight55 lbs/1000ft
Minimum Minor Axis Bend Radius3.25 in
Maximum Recommended Pulling Tension125 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG20
Inner Shield — TypeBraid
Outer Shield — TypeBraid
Conductor — MaterialBC - Bare Copper
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Inner Jacket — MaterialPE - Polyethylene
Inner Shield — MaterialBare Copper (BC)
Outer Jacket — MaterialPE - Polyethylene
Outer Shield — MaterialBare Copper (BC)
Inner Shield — Coverage [%]95%
Outer Shield — Coverage [%]80%
Conductor — Nominal Diameter0.032 in
Insulation — Nominal Diameter0.145 in
Inner Jacket — Nominal Diameter0.225 in
Outer Jacket — Nominal Diameter0.315 in

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor/Outdoor
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account