Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 8232 0101000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Conductor AWG: 20
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor Nominal Diameter: 0.032 in
- Conductor No. of Coax: 1
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nominal Diameter: 0.145 in
- Inner Shield Type: Braid
Belden 8232 0101000 is an orderable item number in the Belden 8232 family (Cable › Broadcast Cable › Video Triax Cable). 20 AWG solid .032" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shields (95% and 80% coverage), polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825355687. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.334 Revision Date: 02-20-2026 |
Standards
| RG Type | 59 |
This Item
| UPC | 612825355687 |
| Color | Black |
| Length | 1,000 ft |
| Item Number | 8232 0101000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Aerial | Yes - When supported by messenger wire |
| Suitability - Burial | Yes |
| Suitability - Indoor | Yes |
| Suitability - Outdoor | Yes |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
| Plenum Number | 88232 |
Temperature Range
| Non-UL Temp Rating | 80°C |
| Operating Temperature Range | -55°C To +80°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
Electrical Characteristics
| Delay — Nominal Delay | 1.22 ns/ft |
| Inductance — Nominal Inductance | 0.097 μH/ft |
| Voltage — Non-UL Voltage Rating | 300 V RMS |
| Return Loss Row 1 — Frequency [MHz] | 5-850 MHz |
| Return Loss Row 2 — Frequency [MHz] | 850-3000 MHz |
| Conductor DCR — Nominal Conductor DCR | 10 Ohm/1000ft |
| Conductor DCR — Nominal Inner Shield DCR | 2.5 Ohm/1000ft |
| Conductor DCR — Nominal Outer Shield DCR | 2.8 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 75 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 83% |
| Capacitance — Nom. Capacitance Conductor To Shield | 16.2 pF/ft |
| Return Loss Row 1 — Min. Structural Return Loss (SRL) | 21 dB |
| Return Loss Row 2 — Min. Structural Return Loss (SRL) | 15 dB |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 3.6 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 71.5 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 135 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 270 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 360 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 540 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 720 MHz |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 750 MHz |
| High Frequency (Nominal/Typical) Row 11 — Frequency [MHz] | 1000 MHz |
| High Frequency (Nominal/Typical) Row 12 — Frequency [MHz] | 1500 MHz |
| High Frequency (Nominal/Typical) Row 13 — Frequency [MHz] | 2250 MHz |
| High Frequency (Nominal/Typical) Row 14 — Frequency [MHz] | 3000 MHz |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 10 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.3 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 0.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 0.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 2.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 3 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 4.2 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 4.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 5.9 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 7 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 7.1 dB/100ft |
| High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss | 8.3 dB/100ft |
| High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss | 10.5 dB/100ft |
| High Frequency (Nominal/Typical) Row 13 — Nom. Insertion Loss | 13.4 dB/100ft |
| High Frequency (Nominal/Typical) Row 14 — Nom. Insertion Loss | 15.9 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 55 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 3.25 in |
| Maximum Recommended Pulling Tension | 125 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 20 |
| Inner Shield — Type | Braid |
| Outer Shield — Type | Braid |
| Conductor — Material | BC - Bare Copper |
| Insulation Table Notes | Gas Injected |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Conductor — No. Of Coax | 1 |
| Inner Jacket — Material | PE - Polyethylene |
| Inner Shield — Material | Bare Copper (BC) |
| Outer Jacket — Material | PE - Polyethylene |
| Outer Shield — Material | Bare Copper (BC) |
| Inner Shield — Coverage [%] | 95% |
| Outer Shield — Coverage [%] | 80% |
| Conductor — Nominal Diameter | 0.032 in |
| Insulation — Nominal Diameter | 0.145 in |
| Inner Jacket — Nominal Diameter | 0.225 in |
| Outer Jacket — Nominal Diameter | 0.315 in |
Applicable Environmental And Other Programs
| EU CE Mark | No |
| Environmental Space | Indoor/Outdoor |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing