Belden Store
Belden 82241 8771000 — Analog Video, RG59, #23 Solid BCCS, 95% BC Braid, Flamarrest® Jacket, CMP

Belden Cable

Belden|

MPN: 82241 8771000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 82241 8771000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 23
  • Conductor Stranding: Solid
  • Conductor Material: BCCS - Bare Copper Covered Steel
  • Conductor Nominal Diameter: 0.023 in
  • Conductor No. of Coax: 1
  • Insulation Material: FEP - Fluorinated Ethylene Propylene
  • Insulation Nominal Diameter: 0.134 in
  • Outer Shield Type: Braid
Belden 82241 8771000 is an orderable item number in the Belden 82241 family (Cable › Video Cable › Coaxial Video Cable). 23 AWG Solid .023" bare copper-covered steel conductor, plenum, FEP insulation, bare copper braid shield (95% coverage), Flamarrest® jacket. This item: Color Natural, Put-Up Type Reel, Length 1,000 ft, UPC 612825196457. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.358 Revision Date: 02-20-2026

Standards

RG Type59
Series Type59
NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825196457
ColorNatural
Length1,000 ft
Item Number82241 8771000
Put-Up TypeReel

Suitability

Suitability - IndoorYes

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

Non-UL Temp Rating75°C
UL Temperature Rating60°C
Operating Temperature Range-20°C To +75°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.
Non-Plenum Number8241

Electrical Characteristics

Delay — Nominal Delay1.45 ns/ft
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.126 μH/ft
Voltage — Non-UL Voltage Rating1700 V RMS
Conductor DCR — Outer Conductor DCR2.6 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR49 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR2.6 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]70%
Capacitance — Nom. Capacitance Conductor To Shield19.5 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance49 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.5 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss1 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss2.3 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss3.3 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss5.2 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss8.4 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss11.6 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss13.8 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss14.8 dB/100ft

Mechanical Characteristics

Bulk Cable Weight34 lbs/1000ft
Minimum Minor Axis Bend Radius2 in
Maximum Recommended Pulling Tension62 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG23
Outer Shield — TypeBraid
Conductor — MaterialBCCS - Bare Copper Covered Steel
Conductor — StrandingSolid
Insulation — MaterialFEP - Fluorinated Ethylene Propylene
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialBare Copper (BC)
Outer Shield — Coverage [%]95%
Conductor — Nominal Diameter0.023 in
Insulation — Nominal Diameter0.134 in
Outer Jacket — Nominal Diameter0.19 in
Outer Jacket — Material Trade NameFlamarrest®

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceIndoor - Plenum
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account