Key Features

  • Conductor AWG: 14
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.064 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.285 in
  • Outer Shield Type: Braid
Belden 8213 010500 is an orderable item number in the Belden 8213 family (Cable › Video Cable › Coaxial Video Cable). 14 AWG solid .064" bare copper conductor, gas-injected foam HDPE insulation, bare copper braid shield (95% coverage), polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 500 ft, UPC 612825196211. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.348 Revision Date: 02-20-2026

Standards

RG Type11
Series Type11

This Item

UPC612825196211
ColorBlack
Length500 ft
Item Number8213 010500
Put-Up TypeReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating80°C
Operating Temperature Range-55°C To +80°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.21 ns/ft
Return Loss — Frequency [MHz]5-450 MHz
Inductance — Nominal Inductance0.097 μH/ft
Voltage — Non-UL Voltage Rating300 V RMS
High Frequency — Frequency [MHz]400 MHz
Conductor DCR — Outer Conductor DCR1.1 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR2.6 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR1.1 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Return Loss — Min. Structural Return Loss (SRL)23 dB
Delay — Nominal Velocity Of Propagation (VP) [%]84%
Capacitance — Nom. Capacitance Conductor To Shield16.1 pF/ft
High Frequency — Max. Insertion Loss (Attenuation)4.4 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]450 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance2.6 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.2 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.4 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.9 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss1.3 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss1.9 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss2.9 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss4.1 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss4.8 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss5.2 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Nom. Structural Return Loss (SRL)23 dB

Mechanical Characteristics

Bulk Cable Weight78 lbs/1000ft
Minimum Minor Axis Bend Radius4 in
Maximum Recommended Pulling Tension171 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG14
Outer Shield — TypeBraid
Conductor — MaterialBC - Bare Copper
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPE - Polyethylene
Outer Shield — MaterialBare Copper (BC)
Outer Shield — Coverage [%]95%
Conductor — Nominal Diameter0.064 in
Insulation — Nominal Diameter0.285 in
Outer Jacket — Nominal Diameter0.405 in

Applicable Environmental And Other Programs

EU CE MarkYes
Environmental SpaceIndoor/Outdoor
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account