Key Features

  • Suitable Applications: Category 5e, UTP Based Video Applications, and KVM
  • Conductor Size: 24
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor No. of Pairs: 4
  • Insulation Material: PO - Polyolefin
  • Insulation Color Code: White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
  • Outer Jacket Material: PVC - Polyvinyl Chloride
Belden 7988R N3UU1000 is an orderable item number in the Belden 7988R family (Cable › Ethernet Cable › Category 5e Cable). Category 5e, 24 AWG bonded pairs solid bare copper conductors, non-plenum, polyolefin insulation, skew 9.0ns/100m nominal, rip cord, PVC jacket. This item: Color Green, Mil, Putup Type UnReel, Length 1,000 ft, UPC 612825192558. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.463 Revision Date: 07-30-2026

This Item

UPC612825192558
ColorGreen, Mil
Length1,000 ft
Putup TypeUnReel
Item Number7988R N3UU1000

Product Notes

NotesJacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e.

Product Overview

Suitable ApplicationsCategory 5e, UTP Based Video Applications, and KVM

Product Life Cycle

Life CycleDiscontinued - the product is no longer manufactured
Discontinuation Announcement Date2008-09-09

Construction Details

Conductor — Size24
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialPO - Polyolefin
Outer Jacket — RipcordYes
Insulation — Color CodeWhite/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor — No. Of Pairs4
Outer Jacket — Nom. Diameter0.204 in

Standards And Compliance

Plenum Number7988P
CPR ComplianceCPR Euroclass: Eca
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ISO/IEC Compliance11801 Category 5
TIA/EIA ComplianceANSI/TIA-568.2-D Category 5e
NEC / UL ComplianceCMR
CEC / C(UL) ComplianceCMG.
UK Regulation ComplianceUKCA Mark
Environmental SuitabilityIndoor - Riser, Indoor
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL1666 Riser

Electrical Characteristics

Delay — Max. Delay0.027 ns/ft
Voltage — UL Voltage Rating300 V (CMR)
Delay — Nom. Velocity Of Prop.70%
Electricals — Max. Conductor DCR90 Ohm/km (27 Ohm/1000ft)
High Frequency Row 1 — Min. ACR [DB]60.3
High Frequency Row 2 — Min. ACR [DB]49.2
High Frequency Row 3 — Min. ACR [DB]43
High Frequency Row 4 — Min. ACR [DB]40.8
High Frequency Row 5 — Min. ACR [DB]36
High Frequency Row 6 — Min. ACR [DB]33.5
High Frequency Row 7 — Min. ACR [DB]30.9
High Frequency Row 8 — Min. ACR [DB]28.2
High Frequency Row 9 — Min. ACR [DB]18.4
High Frequency Row 1 — Min. NEXT [DB]65.3
High Frequency Row 10 — Min. ACR [DB]10.3
High Frequency Row 11 — Min. ACR [DB]2
High Frequency Row 12 — Min. ACR [DB]1
High Frequency Row 2 — Min. NEXT [DB]56.3
High Frequency Row 3 — Min. NEXT [DB]51.8
High Frequency Row 4 — Min. NEXT [DB]50.3
High Frequency Row 5 — Min. NEXT [DB]47.3
High Frequency Row 6 — Min. NEXT [DB]45.8
High Frequency Row 7 — Min. NEXT [DB]44.3
High Frequency Row 8 — Min. NEXT [DB]42.9
High Frequency Row 9 — Min. NEXT [DB]38.4
High Frequency Row 1 — Frequency [MHz]1
High Frequency Row 1 — Min. PSACR [DB]60.3
High Frequency Row 10 — Min. NEXT [DB]35.3
High Frequency Row 11 — Min. NEXT [DB]32.5
High Frequency Row 12 — Min. NEXT [DB]30.8
High Frequency Row 2 — Frequency [MHz]4
High Frequency Row 2 — Min. PSACR [DB]49.2
High Frequency Row 3 — Frequency [MHz]8
High Frequency Row 3 — Min. PSACR [DB]43
High Frequency Row 4 — Frequency [MHz]10
High Frequency Row 4 — Min. PSACR [DB]40.8
High Frequency Row 5 — Frequency [MHz]16
High Frequency Row 5 — Min. PSACR [DB]36
High Frequency Row 6 — Frequency [MHz]20
High Frequency Row 6 — Min. PSACR [DB]33.5
High Frequency Row 7 — Frequency [MHz]25
High Frequency Row 7 — Min. PSACR [DB]30.9
High Frequency Row 8 — Frequency [MHz]31.25
High Frequency Row 8 — Min. PSACR [DB]28.2
High Frequency Row 9 — Frequency [MHz]62.5
High Frequency Row 9 — Min. PSACR [DB]18.4
High Frequency Row 1 — Min. PSNEXT [DB]65.3
High Frequency Row 10 — Frequency [MHz]100
High Frequency Row 10 — Min. PSACR [DB]10.3
High Frequency Row 11 — Frequency [MHz]155
High Frequency Row 11 — Min. PSACR [DB]2
High Frequency Row 12 — Frequency [MHz]200
High Frequency Row 12 — Min. PSACR [DB]1
High Frequency Row 2 — Min. PSNEXT [DB]53.3
High Frequency Row 3 — Min. PSNEXT [DB]48.8
High Frequency Row 4 — Min. PSNEXT [DB]47.3
High Frequency Row 5 — Min. PSNEXT [DB]44.3
High Frequency Row 6 — Min. PSNEXT [DB]42.8
High Frequency Row 7 — Min. PSNEXT [DB]41.3
High Frequency Row 8 — Min. PSNEXT [DB]39.9
High Frequency Row 9 — Min. PSNEXT [DB]35.4
Electricals — Max. Capacitance Unbalance66
High Frequency Row 10 — Min. PSNEXT [DB]32.3
High Frequency Row 11 — Min. PSNEXT [DB]29.5
High Frequency Row 12 — Min. PSNEXT [DB]27.8
High Frequency Row 1 — Min. ACRF (ELFEXT) [DB]63.8
High Frequency Row 2 — Min. ACRF (ELFEXT) [DB]51.7
High Frequency Row 3 — Min. ACRF (ELFEXT) [DB]45.7
High Frequency Row 4 — Min. ACRF (ELFEXT) [DB]43.8
High Frequency Row 5 — Min. ACRF (ELFEXT) [DB]39.7
High Frequency Row 6 — Min. ACRF (ELFEXT) [DB]37.7
High Frequency Row 7 — Min. ACRF (ELFEXT) [DB]35.8
High Frequency Row 8 — Min. ACRF (ELFEXT) [DB]33.9
High Frequency Row 9 — Min. ACRF (ELFEXT) [DB]27.8
High Frequency Row 10 — Min. ACRF (ELFEXT) [DB]23.8
High Frequency Row 11 — Min. ACRF (ELFEXT) [DB]19.9
High Frequency Row 12 — Min. ACRF (ELFEXT) [DB]17.7
High Frequency Row 1 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 1 — Min. RL (Return Loss) [DB]20
High Frequency Row 2 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 2 — Min. RL (Return Loss) [DB]23
High Frequency Row 3 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 3 — Min. RL (Return Loss) [DB]24.5
High Frequency Row 4 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 4 — Min. RL (Return Loss) [DB]25
High Frequency Row 5 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 5 — Min. RL (Return Loss) [DB]25
High Frequency Row 6 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 6 — Min. RL (Return Loss) [DB]25
High Frequency Row 7 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 7 — Min. RL (Return Loss) [DB]24.3
High Frequency Row 8 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 8 — Min. RL (Return Loss) [DB]23.6
High Frequency Row 9 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 9 — Min. RL (Return Loss) [DB]21.5
High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB]60.8
High Frequency Row 10 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 10 — Min. RL (Return Loss) [DB]20.1
High Frequency Row 11 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 11 — Min. RL (Return Loss) [DB]15.8
High Frequency Row 12 — Max./Min. Fitted Impedance100 ± 15
High Frequency Row 12 — Min. RL (Return Loss) [DB]15
High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB]48.7
High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB]42.7
High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB]40.8
High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB]36.7
High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB]34.7
High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB]32.8
High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB]30.9
High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB]24.8
High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB]20.8
High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB]16.9
High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB]14.7
High Frequency Row 1 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 2 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 3 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 4 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 5 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 6 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 7 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 8 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 9 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 10 — Max./Min. Input Impedance (UnFitted)100 ± 15
High Frequency Row 11 — Max./Min. Input Impedance (UnFitted)100 ± 25
High Frequency Row 12 — Max./Min. Input Impedance (UnFitted)100 ± 25
High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m]2
High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m]4.1
High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m]5.8
High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m]6.5
High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m]8.2
High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m]9.3
High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m]10.4
High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m]11.7
High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m]17
High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m]22
High Frequency Row 11 — Max. Insertion Loss (Attenuation) [DB/100m]28.1
High Frequency Row 12 — Max. Insertion Loss (Attenuation) [DB/100m]32.4

Mechanical Characteristics

Bulk Cable Weight20 lbs/1000ft (30 kg/km)
Max. Pull Tension40 lbs (18 kg)
Temperature — Operating-20°C To +75°C
Bend Radius — Stationary Min.0.25 in (6.4 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account