Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 7988R N3UU1000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Category 5e, UTP Based Video Applications, and KVM
- Conductor Size: 24
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor No. of Pairs: 4
- Insulation Material: PO - Polyolefin
- Insulation Color Code: White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
- Outer Jacket Material: PVC - Polyvinyl Chloride
Belden 7988R N3UU1000 is an orderable item number in the Belden 7988R family (Cable › Ethernet Cable › Category 5e Cable). Category 5e, 24 AWG bonded pairs solid bare copper conductors, non-plenum, polyolefin insulation, skew 9.0ns/100m nominal, rip cord, PVC jacket. This item: Color Green, Mil, Putup Type UnReel, Length 1,000 ft, UPC 612825192558. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.463 Revision Date: 07-30-2026 |
This Item
| UPC | 612825192558 |
| Color | Green, Mil |
| Length | 1,000 ft |
| Putup Type | UnReel |
| Item Number | 7988R N3UU1000 |
Product Notes
| Notes | Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e. |
Product Overview
| Suitable Applications | Category 5e, UTP Based Video Applications, and KVM |
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
| Discontinuation Announcement Date | 2008-09-09 |
Construction Details
| Conductor — Size | 24 |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | PO - Polyolefin |
| Outer Jacket — Ripcord | Yes |
| Insulation — Color Code | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor — No. Of Pairs | 4 |
| Outer Jacket — Nom. Diameter | 0.204 in |
Standards And Compliance
| Plenum Number | 7988P |
| CPR Compliance | CPR Euroclass: Eca |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ISO/IEC Compliance | 11801 Category 5 |
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 5e |
| NEC / UL Compliance | CMR |
| CEC / C(UL) Compliance | CMG. |
| UK Regulation Compliance | UKCA Mark |
| Environmental Suitability | Indoor - Riser, Indoor |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL1666 Riser |
Electrical Characteristics
| Delay — Max. Delay | 0.027 ns/ft |
| Voltage — UL Voltage Rating | 300 V (CMR) |
| Delay — Nom. Velocity Of Prop. | 70% |
| Electricals — Max. Conductor DCR | 90 Ohm/km (27 Ohm/1000ft) |
| High Frequency Row 1 — Min. ACR [DB] | 60.3 |
| High Frequency Row 2 — Min. ACR [DB] | 49.2 |
| High Frequency Row 3 — Min. ACR [DB] | 43 |
| High Frequency Row 4 — Min. ACR [DB] | 40.8 |
| High Frequency Row 5 — Min. ACR [DB] | 36 |
| High Frequency Row 6 — Min. ACR [DB] | 33.5 |
| High Frequency Row 7 — Min. ACR [DB] | 30.9 |
| High Frequency Row 8 — Min. ACR [DB] | 28.2 |
| High Frequency Row 9 — Min. ACR [DB] | 18.4 |
| High Frequency Row 1 — Min. NEXT [DB] | 65.3 |
| High Frequency Row 10 — Min. ACR [DB] | 10.3 |
| High Frequency Row 11 — Min. ACR [DB] | 2 |
| High Frequency Row 12 — Min. ACR [DB] | 1 |
| High Frequency Row 2 — Min. NEXT [DB] | 56.3 |
| High Frequency Row 3 — Min. NEXT [DB] | 51.8 |
| High Frequency Row 4 — Min. NEXT [DB] | 50.3 |
| High Frequency Row 5 — Min. NEXT [DB] | 47.3 |
| High Frequency Row 6 — Min. NEXT [DB] | 45.8 |
| High Frequency Row 7 — Min. NEXT [DB] | 44.3 |
| High Frequency Row 8 — Min. NEXT [DB] | 42.9 |
| High Frequency Row 9 — Min. NEXT [DB] | 38.4 |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 1 — Min. PSACR [DB] | 60.3 |
| High Frequency Row 10 — Min. NEXT [DB] | 35.3 |
| High Frequency Row 11 — Min. NEXT [DB] | 32.5 |
| High Frequency Row 12 — Min. NEXT [DB] | 30.8 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 2 — Min. PSACR [DB] | 49.2 |
| High Frequency Row 3 — Frequency [MHz] | 8 |
| High Frequency Row 3 — Min. PSACR [DB] | 43 |
| High Frequency Row 4 — Frequency [MHz] | 10 |
| High Frequency Row 4 — Min. PSACR [DB] | 40.8 |
| High Frequency Row 5 — Frequency [MHz] | 16 |
| High Frequency Row 5 — Min. PSACR [DB] | 36 |
| High Frequency Row 6 — Frequency [MHz] | 20 |
| High Frequency Row 6 — Min. PSACR [DB] | 33.5 |
| High Frequency Row 7 — Frequency [MHz] | 25 |
| High Frequency Row 7 — Min. PSACR [DB] | 30.9 |
| High Frequency Row 8 — Frequency [MHz] | 31.25 |
| High Frequency Row 8 — Min. PSACR [DB] | 28.2 |
| High Frequency Row 9 — Frequency [MHz] | 62.5 |
| High Frequency Row 9 — Min. PSACR [DB] | 18.4 |
| High Frequency Row 1 — Min. PSNEXT [DB] | 65.3 |
| High Frequency Row 10 — Frequency [MHz] | 100 |
| High Frequency Row 10 — Min. PSACR [DB] | 10.3 |
| High Frequency Row 11 — Frequency [MHz] | 155 |
| High Frequency Row 11 — Min. PSACR [DB] | 2 |
| High Frequency Row 12 — Frequency [MHz] | 200 |
| High Frequency Row 12 — Min. PSACR [DB] | 1 |
| High Frequency Row 2 — Min. PSNEXT [DB] | 53.3 |
| High Frequency Row 3 — Min. PSNEXT [DB] | 48.8 |
| High Frequency Row 4 — Min. PSNEXT [DB] | 47.3 |
| High Frequency Row 5 — Min. PSNEXT [DB] | 44.3 |
| High Frequency Row 6 — Min. PSNEXT [DB] | 42.8 |
| High Frequency Row 7 — Min. PSNEXT [DB] | 41.3 |
| High Frequency Row 8 — Min. PSNEXT [DB] | 39.9 |
| High Frequency Row 9 — Min. PSNEXT [DB] | 35.4 |
| Electricals — Max. Capacitance Unbalance | 66 |
| High Frequency Row 10 — Min. PSNEXT [DB] | 32.3 |
| High Frequency Row 11 — Min. PSNEXT [DB] | 29.5 |
| High Frequency Row 12 — Min. PSNEXT [DB] | 27.8 |
| High Frequency Row 1 — Min. ACRF (ELFEXT) [DB] | 63.8 |
| High Frequency Row 2 — Min. ACRF (ELFEXT) [DB] | 51.7 |
| High Frequency Row 3 — Min. ACRF (ELFEXT) [DB] | 45.7 |
| High Frequency Row 4 — Min. ACRF (ELFEXT) [DB] | 43.8 |
| High Frequency Row 5 — Min. ACRF (ELFEXT) [DB] | 39.7 |
| High Frequency Row 6 — Min. ACRF (ELFEXT) [DB] | 37.7 |
| High Frequency Row 7 — Min. ACRF (ELFEXT) [DB] | 35.8 |
| High Frequency Row 8 — Min. ACRF (ELFEXT) [DB] | 33.9 |
| High Frequency Row 9 — Min. ACRF (ELFEXT) [DB] | 27.8 |
| High Frequency Row 10 — Min. ACRF (ELFEXT) [DB] | 23.8 |
| High Frequency Row 11 — Min. ACRF (ELFEXT) [DB] | 19.9 |
| High Frequency Row 12 — Min. ACRF (ELFEXT) [DB] | 17.7 |
| High Frequency Row 1 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 1 — Min. RL (Return Loss) [DB] | 20 |
| High Frequency Row 2 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 2 — Min. RL (Return Loss) [DB] | 23 |
| High Frequency Row 3 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 3 — Min. RL (Return Loss) [DB] | 24.5 |
| High Frequency Row 4 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 4 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 5 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 5 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 6 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 6 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 7 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 7 — Min. RL (Return Loss) [DB] | 24.3 |
| High Frequency Row 8 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 8 — Min. RL (Return Loss) [DB] | 23.6 |
| High Frequency Row 9 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 9 — Min. RL (Return Loss) [DB] | 21.5 |
| High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB] | 60.8 |
| High Frequency Row 10 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 10 — Min. RL (Return Loss) [DB] | 20.1 |
| High Frequency Row 11 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 11 — Min. RL (Return Loss) [DB] | 15.8 |
| High Frequency Row 12 — Max./Min. Fitted Impedance | 100 ± 15 |
| High Frequency Row 12 — Min. RL (Return Loss) [DB] | 15 |
| High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB] | 48.7 |
| High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB] | 42.7 |
| High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB] | 40.8 |
| High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB] | 36.7 |
| High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB] | 34.7 |
| High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB] | 32.8 |
| High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB] | 30.9 |
| High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB] | 24.8 |
| High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB] | 20.8 |
| High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB] | 16.9 |
| High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB] | 14.7 |
| High Frequency Row 1 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 2 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 3 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 4 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 5 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 6 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 7 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 8 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 9 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 10 — Max./Min. Input Impedance (UnFitted) | 100 ± 15 |
| High Frequency Row 11 — Max./Min. Input Impedance (UnFitted) | 100 ± 25 |
| High Frequency Row 12 — Max./Min. Input Impedance (UnFitted) | 100 ± 25 |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m] | 2 |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m] | 4.1 |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m] | 5.8 |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m] | 6.5 |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m] | 8.2 |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m] | 9.3 |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m] | 10.4 |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m] | 11.7 |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m] | 17 |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m] | 22 |
| High Frequency Row 11 — Max. Insertion Loss (Attenuation) [DB/100m] | 28.1 |
| High Frequency Row 12 — Max. Insertion Loss (Attenuation) [DB/100m] | 32.4 |
Mechanical Characteristics
| Bulk Cable Weight | 20 lbs/1000ft (30 kg/km) |
| Max. Pull Tension | 40 lbs (18 kg) |
| Temperature — Operating | -20°C To +75°C |
| Bend Radius — Stationary Min. | 0.25 in (6.4 mm) |