Key Features

  • Suitable Applications: Surveillance, CCTV Camera
  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 1
  • Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
  • Insulation Material Trade Name: Teflon®
Belden 7985LC 010500 is an orderable item number in the Belden 7985LC family (Cable › Coax & Triax Cable › CCTV & Security Cable). Surveillance & CCTV Cable, RG6, Plenum-CMP-FHC 25/50, 18 AWG bare copper foam FEP core, 95% bare copper braid, FEP jacket This item: Color Black, Put-Up Type Reel, Length 500 ft, UPC 612825192466. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.376 Revision Date: 02-20-2026

Standards

RG Type6
Series Type6
NEC ArticlesArticle 800
NEC/(UL) ComplianceLimited Combustible FHC 25/50 CMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825192466
ColorBlack
Length500 ft
Item Number7985LC 010500
Put-Up TypeReel

Product Notes

NotesTeflon« is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.

Product Overview

Suitable ApplicationsSurveillance, CCTV Camera

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

UL Temperature Rating200°C
Operating Temperature Range-40°C To +200°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.24 ns/ft
Delay — Max. Delay Skew83 ns/100m
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.097 μH/ft
Conductor DCR — Nominal Conductor DCR6.4 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR2.2 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.3 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]3 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]8 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 12 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.24 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.45 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.55 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss0.7 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss0.85 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss1.5 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss2.1 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss3.1 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss4.7 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss6.8 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss8 dB/100ft
High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss8.5 dB/100ft

Mechanical Characteristics

Bulk Cable Weight41 lbs/1000ft
Minimum Minor Axis Bend Radius2.25 in
Min Bend Radius (Overall Cable)1.04
Maximum Recommended Pulling Tension84 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Outer Shield — TypeBraid
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialFEP - Fluorinated Ethylene Propylene
Outer Shield — MaterialBare Copper (BC)
Outer Shield — Coverage [%]95%
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.17 in
Outer Jacket — Nominal Diameter0.228 in
Insulation — Material Trade NameTeflon®
Outer Jacket — Material Trade NameTeflon®

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL723 (NFPA 255)
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account