Belden Store
Belden 7916A 0105000 — DBS Cable, RG6, 18 AWG BC, Quad Shield, CM

Belden Cable

Belden|

MPN: 7916A 0105000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 7916A 0105000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: HDTV, DBS, Broadband CATV, Cable Modem
  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.04 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.18 in
Belden 7916A 0105000 is an orderable item number in the Belden 7916A family (Cable › Video Cable › CATV Cable). Series 6, 18 AWG solid .040" bare copper conductor, gas-injected foam polyethylene insulation, Duobond®; aluminum braid shields (60% and 40% coverage), PVC jacket (black or white). This item: Color Black, Put-Up Type Reel, Length 5,000 ft, UPC 612825191087. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.468 Revision Date: 02-20-2026

Standards

RG Type6
Series Type6
CPR EuroclassEca
NEC/(UL) ComplianceCATV, CM
CEC/C(UL) ComplianceCM

This Item

UPC612825191087
ColorBlack
Length5,000 ft
Item Number7916A 0105000
Put-Up TypeReel

Suitability

Suitability - IndoorYes

Product Overview

Suitable ApplicationsHDTV, DBS, Broadband CATV, Cable Modem

Plenum/Non-Plenum

Plenum (Y/N)No
Plenum Number7916AP

Temperature Range

Operating Temperature Range-40°C To +75°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.2 ns/ft
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.097 μH/ft
Screening Row 1 — Frequency [MHz]5 MHz
Screening Row 2 — Frequency [MHz]50 MHz
Screening Row 3 — Frequency [MHz]50 MHz
Screening Row 4 — Frequency [MHz]1000 MHz
Conductor DCR — Outer Conductor DCR4.8 Ohm/1000ft
Return Loss Row 1 — Frequency [MHz]5-1000 MHz
Return Loss Row 2 — Frequency [MHz]1000-2250 MHz
Return Loss Row 3 — Frequency [MHz]2250-3000 MHz
Conductor DCR — Nominal Conductor DCR6.4 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]5 MHz
High Frequency Row 2 — Frequency [MHz]55 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]500 MHz
High Frequency Row 5 — Frequency [MHz]750 MHz
High Frequency Row 6 — Frequency [MHz]862 MHz
High Frequency Row 7 — Frequency [MHz]1000 MHz
High Frequency Row 8 — Frequency [MHz]1450 MHz
High Frequency Row 9 — Frequency [MHz]1800 MHz
Screening Row 2 — Shield Effectiveness110 dB
High Frequency Row 10 — Frequency [MHz]2250 MHz
High Frequency Row 11 — Frequency [MHz]3000 MHz
Conductor DCR — Nominal Outer Shield DCR4.8 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.2 pF/ft
Return Loss Row 1 — Min. Structural Return Loss (SRL)20 dB
Return Loss Row 2 — Min. Structural Return Loss (SRL)15 dB
Return Loss Row 3 — Min. Structural Return Loss (SRL)10 dB
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]5 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]55 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]211 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]500 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]750 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]862 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]1000 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]1450 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1800 MHz
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.58 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)1.6 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)3.05 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)4.66 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)5.65 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)6.1 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)6.55 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)8 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)8.8 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]2250 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]3000 MHz
High Frequency Row 10 — Max. Insertion Loss (Attenuation)10 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)11.9 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.5 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss1.4 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss2.6 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss4.1 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss5.1 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss5.5 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss6 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss7.8 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss8.6 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss9.8 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss11.3 dB/100ft
High Frequency (Nominal/Typical) Row 1 — Nom. Structural Return Loss (SRL)30 dB
High Frequency (Nominal/Typical) Row 2 — Nom. Structural Return Loss (SRL)24 dB

Mechanical Characteristics

Bulk Cable Weight33 lbs/1000ft
Minimum Minor Axis Bend Radius3 in
Maximum Recommended Pulling Tension104 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Conductor — MaterialBC - Bare Copper
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 3 — TypeTape
Outer Shield Row 4 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Outer Shield Row 3 — Layer3
Outer Shield Row 4 — Layer4
Conductor — Nominal Diameter0.04 in
Insulation — Nominal Diameter0.18 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Shield Row 3 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 4 — MaterialAluminum
Outer Jacket — Nominal Diameter0.298 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 3 — Coverage [%]100%
Outer Shield Row 4 — Coverage [%]40%
Outer Shield Row 1 — Material Trade NameDuobond® II
Outer Shield Row 3 — Material Trade NameDuofoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
Environmental SpaceIndoor (Not Riser or Plenum)
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account