Key Features

  • Suitable Applications: Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10Base - T, FDDI, ATM
  • Conductor Size: 23 AWG
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor No. of Pairs: 4
  • Insulation Material: PE - Polyethylene
  • Insulation Nom. Insulation Diameter: 1.15 mm (0.0453 in)
  • Insulation Color Code: Blue & White with Blue Strip, Orange & White with Orange Strip, Green & White with Green Strip, Brown & White with Brown Strip
Belden 7834BNC 006A1000 is an orderable item number in the Belden 7834BNC family (Cable › Ethernet Cable › Category 6 Cable). Category 6+ Premise Horizontal Cable (650MHz), 4 Bonded-Pairs, 23 AWG Solid Bare Copper Conductors, U/UTP, LSZH Jacket, Indoor This item: Color Blue, Putup Type Reel in Box, Length 1,000 ft. Ships from and sold by A5 IT. Quoted to order.

History

Footnote*Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length.
Update And RevisionRevision Number: 0.26 Revision Date: 02-20-2026

This Item

ColorBlue
Length1,000 ft
Putup TypeReel in Box
Item Number7834BNC 006A1000

Product Overview

Suitable ApplicationsHorizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base - T (Gigabit Ethernet), 100 Base - T, 10Base - T, FDDI, ATM

Construction Details

Bonded-PairYes
Conductor — Size23 AWG
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene
Insulation — Color CodeBlue & White with Blue Strip, Orange & White with Orange Strip, Green & White with Green Strip, Brown & White with Brown Strip
Outer Jacket — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Conductor — No. Of Pairs4
Outer Jacket — Nom. Diameter6.3 mm (0.25 in)
Insulation — Nom. Insulation Diameter1.15 mm (0.0453 in)

Standards And Compliance

CENELEC ComplianceEN 50173-1
ISO/IEC ComplianceIEC 61156-5, ISO/IEC 11801
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = HCL+HBr ≤ 0.5%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3
Flammability / Reaction To FireIEC 60332-1-2, IEC 60332-3-22

Electrical Characteristics

Delay — Max. Delay Skew40 ns/100m
High Frequency Table NotesThe cable performance between 1 MHz and 4 MHz,Frequency range exceeding 250MHz is achieved by design only and it is therefore not necessary to test for this performance below 4 MHz. Reference standard: ISO/IEC 61156-5ed. 2.0 (2009)The value of transmission performance is typical.
Delay — Nom. Velocity Of Prop.67%
Electricals — Max. Conductor DCR95 Ohm/km (29 Ohm/1000ft)
High Frequency Row 1 — Min. ACR [DB]78.3
High Frequency Row 1 — Min. TCL [DB]40
High Frequency Row 2 — Min. ACR [DB]67.6
High Frequency Row 2 — Min. TCL [DB]34
High Frequency Row 3 — Min. ACR [DB]59.6
High Frequency Row 3 — Min. TCL [DB]30
High Frequency Row 4 — Min. ACR [DB]55.0
High Frequency Row 4 — Min. TCL [DB]28
High Frequency Row 5 — Min. ACR [DB]47.7
High Frequency Row 5 — Min. TCL [DB]25.1
High Frequency Row 6 — Min. ACR [DB]38.8
High Frequency Row 6 — Min. TCL [DB]22
High Frequency Row 7 — Min. ACR [DB]31.5
High Frequency Row 7 — Min. TCL [DB]20
High Frequency Row 8 — Min. ACR [DB]27.6
High Frequency Row 8 — Min. TCL [DB]19
High Frequency Row 9 — Min. ACR [DB]18.4
High Frequency Row 9 — Min. TCL [DB]17
Electricals — Max. Mutual Capacitance56 pF/m (17 pF/ft)
High Frequency Row 1 — Min. NEXT [DB]80.3
High Frequency Row 10 — Min. ACR [DB]13.2
High Frequency Row 10 — Min. TCL [DB]16
High Frequency Row 2 — Min. NEXT [DB]71.3
High Frequency Row 3 — Min. NEXT [DB]65.3
High Frequency Row 4 — Min. NEXT [DB]62.2
High Frequency Row 5 — Min. NEXT [DB]57.9
High Frequency Row 6 — Min. NEXT [DB]53.4
High Frequency Row 7 — Min. NEXT [DB]50.3
High Frequency Row 8 — Min. NEXT [DB]48.8
High Frequency Row 9 — Min. NEXT [DB]45.8
High Frequency Row 1 — Frequency [MHz]1
High Frequency Row 1 — Min. PSACR [DB]76.3
High Frequency Row 10 — Min. NEXT [DB]44.3
High Frequency Row 11 — Min. NEXT [DB]42.1
High Frequency Row 12 — Min. NEXT [DB]39.8
High Frequency Row 13 — Min. NEXT [DB]38.1
High Frequency Row 2 — Frequency [MHz]4
High Frequency Row 2 — Min. PSACR [DB]65.6
High Frequency Row 3 — Frequency [MHz]10
High Frequency Row 3 — Min. PSACR [DB]57.6
High Frequency Row 4 — Frequency [MHz]16
High Frequency Row 4 — Min. PSACR [DB]53.0
High Frequency Row 5 — Frequency [MHz]31.3
High Frequency Row 5 — Min. PSACR [DB]45.7
High Frequency Row 6 — Frequency [MHz]62.5
High Frequency Row 6 — Min. PSACR [DB]36.8
High Frequency Row 7 — Frequency [MHz]100
High Frequency Row 7 — Min. PSACR [DB]29.5
High Frequency Row 8 — Frequency [MHz]125
High Frequency Row 8 — Min. PSACR [DB]25.6
High Frequency Row 9 — Frequency [MHz]200
High Frequency Row 9 — Min. PSACR [DB]16.4
High Frequency Row 1 — Min. ELTCTL [DB]35
High Frequency Row 1 — Min. PSNEXT [DB]78.3
High Frequency Row 10 — Frequency [MHz]250
High Frequency Row 10 — Min. PSACR [DB]11.2
High Frequency Row 11 — Frequency [MHz]350
High Frequency Row 12 — Frequency [MHz]500
High Frequency Row 13 — Frequency [MHz]650
High Frequency Row 2 — Min. ELTCTL [DB]23
High Frequency Row 2 — Min. PSNEXT [DB]69.3
High Frequency Row 3 — Min. ELTCTL [DB]15
High Frequency Row 3 — Min. PSNEXT [DB]63.3
High Frequency Row 4 — Min. ELTCTL [DB]10.9
High Frequency Row 4 — Min. PSNEXT [DB]60.2
High Frequency Row 5 — Min. ELTCTL [DB]5.1
High Frequency Row 5 — Min. PSNEXT [DB]55.9
High Frequency Row 6 — Min. PSNEXT [DB]51.4
High Frequency Row 7 — Min. PSNEXT [DB]48.3
High Frequency Row 8 — Min. PSNEXT [DB]46.8
High Frequency Row 9 — Min. PSNEXT [DB]43.8
Electricals — Max. Capacitance Unbalance160 pF/100m
High Frequency Row 10 — Min. PSNEXT [DB]42.3
High Frequency Row 11 — Min. PSNEXT [DB]40.1
High Frequency Row 12 — Min. PSNEXT [DB]37.8
High Frequency Row 13 — Min. PSNEXT [DB]36.1
Electricals — Nom. Characteristic Impedance100 Ohm
High Frequency Row 1 — Min. ACRF (ELFEXT) [DB]74
High Frequency Row 2 — Min. ACRF (ELFEXT) [DB]62
High Frequency Row 3 — Min. ACRF (ELFEXT) [DB]54
High Frequency Row 4 — Min. ACRF (ELFEXT) [DB]49.9
High Frequency Row 5 — Min. ACRF (ELFEXT) [DB]44.1
High Frequency Row 6 — Min. ACRF (ELFEXT) [DB]38.1
High Frequency Row 7 — Min. ACRF (ELFEXT) [DB]34
High Frequency Row 8 — Min. ACRF (ELFEXT) [DB]32.1
High Frequency Row 9 — Min. ACRF (ELFEXT) [DB]28
High Frequency Row 10 — Min. ACRF (ELFEXT) [DB]26
High Frequency Row 11 — Min. ACRF (ELFEXT) [DB]23.1
High Frequency Row 12 — Min. ACRF (ELFEXT) [DB]20
High Frequency Row 13 — Min. ACRF (ELFEXT) [DB]17.7
High Frequency Row 1 — Min. RL (Return Loss) [DB]23
High Frequency Row 2 — Min. RL (Return Loss) [DB]26
High Frequency Row 3 — Min. RL (Return Loss) [DB]28
High Frequency Row 4 — Min. RL (Return Loss) [DB]28
High Frequency Row 5 — Min. RL (Return Loss) [DB]26.6
High Frequency Row 6 — Min. RL (Return Loss) [DB]24.5
High Frequency Row 7 — Min. RL (Return Loss) [DB]23.1
High Frequency Row 8 — Min. RL (Return Loss) [DB]22.4
High Frequency Row 9 — Min. RL (Return Loss) [DB]21
High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB]71
High Frequency Row 10 — Min. RL (Return Loss) [DB]20.3
High Frequency Row 11 — Min. RL (Return Loss) [DB]19.3
High Frequency Row 12 — Min. RL (Return Loss) [DB]19.3
High Frequency Row 13 — Min. RL (Return Loss) [DB]19.3
High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB]59
High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB]51
High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB]46.9
High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB]41.1
High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB]35.1
High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB]31
High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB]29.1
High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB]25
High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB]23
High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB]20.1
High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB]17
High Frequency Row 13 — Min. PSACRF (PSELFEXT) [DB]14.7
High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m]2.0
High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m]3.7
High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m]5.7
High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m]7.2
High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m]10.2
High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m]14.6
High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m]18.8
High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m]21.2
High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m]27.4
High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m]31.1
High Frequency Row 11 — Max. Insertion Loss (Attenuation) [DB/100m]37.6
High Frequency Row 12 — Max. Insertion Loss (Attenuation) [DB/100m]46.3
High Frequency Row 13 — Max. Insertion Loss (Attenuation) [DB/100m]54.0

Mechanical Characteristics

Bulk Cable Weight46 kg/km (31 lbs/1000ft)
Temperature — Operating-30°C To +60°C
Bend Radius — Installation Min.8*D

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account