Belden Store
Belden 7810WB 0101000 — RF400 Wireless Coax, RG8, #10, Waterblocked

Belden Cable

Belden|

MPN: 7810WB 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 7810WB 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 10
  • Conductor Stranding: Solid
  • Conductor Material: BCCA - Bare Copper Covered Aluminum
  • Conductor Nominal Diameter: 0.108 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.285 in
  • Outer Jacket Material: PE - Polyethylene
Belden 7810WB 0101000 is an orderable item number in the Belden 7810WB family (Cable › Coax & Triax Cable › 50 Ohm Coax Cable). RG-8 type, 10 AWG solid .108" bare copper-covered aluminum conductor, gas-injected foam HDPE insulation, Duobond® II, tinned copper braid shield (95% coverage), flooded water-resistant polyethylene jacket. This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825189848. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.377 Revision Date: 02-20-2026

Standards

RG Type8

This Item

UPC612825189848
ColorBlack
Length1,000 ft
Item Number7810WB 0101000
Put-Up TypeReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - BurialYes
Suitability - IndoorYes
Suitability - OutdoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Non-UL Temp Rating80°C
Operating Temperature Range-40°C To +75°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Table Notes51.0 +/- 2.0 Ohms
VSWR — Max. VSWR1.25:1
Delay — Nominal Delay1.17 ns/ft
VSWR — Frequency [MHz]5-6000 MHz
Inductance — Nominal Inductance0.06 μH/ft
Voltage — Non-UL Voltage Rating300 V RMS
Conductor DCR — Outer Conductor DCR2 Ohm/1000ft
Power Rating Row 1 — Frequency [MHz]30 MHz
Power Rating Row 2 — Frequency [MHz]50 MHz
Power Rating Row 3 — Frequency [MHz]150 MHz
Power Rating Row 4 — Frequency [MHz]220 MHz
Power Rating Row 5 — Frequency [MHz]450 MHz
Power Rating Row 6 — Frequency [MHz]900 MHz
Power Rating Row 7 — Frequency [MHz]1,500 MHz
Power Rating Row 8 — Frequency [MHz]2,000 MHz
Power Rating Row 9 — Frequency [MHz]2,500 MHz
Conductor DCR — Nominal Conductor DCR1.34 Ohm/1000ft
Power Rating Row 10 — Frequency [MHz]3,500 MHz
Power Rating Row 11 — Frequency [MHz]4,500 MHz
Power Rating Row 12 — Frequency [MHz]6,000 MHz
Power Rating Row 13 — Frequency [MHz]4,500 MHz
Power Rating Row 14 — Frequency [MHz]5,800 MHz
Power Rating Row 15 — Frequency [MHz]6,000 MHz
Conductor DCR — Nominal Outer Shield DCR2 Ohm/1000ft
Power Rating Row 1 — Max. Power Rating [W]3,427 W
Power Rating Row 2 — Max. Power Rating [W]2,588 W
Power Rating Row 3 — Max. Power Rating [W]1,428 W
Power Rating Row 4 — Max. Power Rating [W]1,195 W
Power Rating Row 5 — Max. Power Rating [W]817 W
Power Rating Row 6 — Max. Power Rating [W]575 W
Power Rating Row 7 — Max. Power Rating [W]437 W
Power Rating Row 8 — Max. Power Rating [W]375 W
Power Rating Row 9 — Max. Power Rating [W]334 W
Power Rating Row 10 — Max. Power Rating [W]282 W
Power Rating Row 11 — Max. Power Rating [W]247 W
Power Rating Row 12 — Max. Power Rating [W]213 W
Power Rating Row 13 — Max. Power Rating [W]247 W
Power Rating Row 14 — Max. Power Rating [W]217 W
Power Rating Row 15 — Max. Power Rating [W]213 W
Impedance — Nominal Characteristic Impedance50 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]86%
Capacitance — Nom. Capacitance Conductor To Shield23 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]30 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]150 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]220 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]450 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]1500 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]1800 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]2000 MHz
High Frequency (Nominal/Typical) Row 10 — Frequency [MHz]2500 MHz
High Frequency (Nominal/Typical) Row 11 — Frequency [MHz]3000 MHz
High Frequency (Nominal/Typical) Row 12 — Frequency [MHz]3500 MHz
High Frequency (Nominal/Typical) Row 13 — Frequency [MHz]4500 MHz
High Frequency (Nominal/Typical) Row 14 — Frequency [MHz]5800 MHz
High Frequency (Nominal/Typical) Row 15 — Frequency [MHz]6000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance1.34 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.7 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.9 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss1.5 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss1.8 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss2.7 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss3.8 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss5.1 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss5.6 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss6 dB/100ft
High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss6.7 dB/100ft
High Frequency (Nominal/Typical) Row 11 — Nom. Insertion Loss7.5 dB/100ft
High Frequency (Nominal/Typical) Row 12 — Nom. Insertion Loss8.2 dB/100ft
High Frequency (Nominal/Typical) Row 13 — Nom. Insertion Loss9.5 dB/100ft
High Frequency (Nominal/Typical) Row 14 — Nom. Insertion Loss11.1 dB/100ft
High Frequency (Nominal/Typical) Row 15 — Nom. Insertion Loss11.4 dB/100ft

Mechanical Characteristics

Bulk Cable Weight73 lbs/1000ft
Minimum Minor Axis Bend Radius4 in
Maximum Recommended Pulling Tension150 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG10
Conductor — MaterialBCCA - Bare Copper Covered Aluminum
Insulation Table NotesGas Injected
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Shield Table NotesPO - Polyolefin
Conductor — No. Of Coax1
Outer Jacket — MaterialPE - Polyethylene
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.108 in
Insulation — Nominal Diameter0.285 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialTinned Copper (TC)
Outer Jacket — Nominal Diameter0.403 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]95%
Outer Shield Row 1 — Material Trade NameDuofoil®

Applicable Environmental And Other Programs

EU CE MarkNo
Environmental SpaceWater Exposure/Below-Grade Conduit
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account