Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 7803A 0101000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Conductor Size: 14
- Conductor Stranding: Solid
- Conductor Nom. Diameter: 0.064 in
- Conductor Material: BC - Bare Copper
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nom. Insulation Diameter: 0.285 in (7.24 mm)
- Inner Shield Shield Type: Braid
- Inner Shield Material: Bare Copper (BC)
Belden 7803A 0101000 is an orderable item number in the Belden 7803A family (Cable › Broadcast Cable › Video Triax Cable). 14 AWG solid .064" bare copper conductor, gas-injected foam HDPE insulation, bare copper double shields (95% and 80% coverage), polyethylene jacket. This item: Color Black, Putup Type Reel, Length 1,000 ft, UPC 612825436010, Footnote C. Ships from and sold by A5 IT. Quoted to order.
History
| Footnote | C - CRATE REEL PUT-UP. |
| Update And Revision | Revision Number: 0.336 Revision Date: 07-30-2026 |
This Item
| UPC | 612825436010 |
| Color | Black |
| Length | 1,000 ft |
| Footnote | C |
| Putup Type | Reel |
| Item Number | 7803A 0101000 |
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
| Discontinuation Announcement Date | 2020-12-15 |
Construction Details
| RG Type | 11 |
| Conductor — Size | 14 |
| Conductor — Material | BC - Bare Copper |
| Insulation Table Notes | Gas Injected |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Outer Shield Table Notes | Polyethylene |
| Inner Jacket — Material | PE - Polyethylene |
| Inner Shield — Coverage | 95% |
| Inner Shield — Material | Bare Copper (BC) |
| Outer Jacket — Material | PE - Polyethylene |
| Outer Shield — Coverage | 80% |
| Outer Shield — Material | Bare Copper (BC) |
| Conductor — Nom. Diameter | 0.064 in |
| Inner Shield — Shield Type | Braid |
| Inner Jacket — Nom. Diameter | 0.365 in (9.27 mm) |
| Outer Jacket — Nom. Diameter | 0.475 in |
| Outer Shield — Outer Shield Type | Braid |
| Insulation — Nom. Insulation Diameter | 0.285 in (7.24 mm) |
Standards And Compliance
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Environmental Suitability | Outdoor - Water Exposure, Indoor, Outdoor, Aerial - When supported by messenger wire, Burial |
| European Directive Compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
Electrical Characteristics
| Voltage — Voltage Rating | 300 V RMS |
| Attenuation Row 1 — Frequency | 1 MHz |
| Attenuation Row 2 — Frequency | 3.6 MHz |
| Attenuation Row 3 — Frequency | 10 MHz |
| Attenuation Row 4 — Frequency | 71.5 MHz |
| Attenuation Row 5 — Frequency | 135 MHz |
| Attenuation Row 6 — Frequency | 270 MHz |
| Attenuation Row 7 — Frequency | 360 MHz |
| Attenuation Row 8 — Frequency | 540 MHz |
| Attenuation Row 9 — Frequency | 720 MHz |
| Return Loss Row 1 — Frequency | 5-850 MHz |
| Return Loss Row 2 — Frequency | 850-3000 MHz |
| Attenuation Row 10 — Frequency | 750 MHz |
| Attenuation Row 11 — Frequency | 1000 MHz |
| Attenuation Row 12 — Frequency | 1500 MHz |
| Attenuation Row 13 — Frequency | 2250 MHz |
| Attenuation Row 14 — Frequency | 3000 MHz |
| Electricals — Nom. Conductor DCR | 2.5 Ohm/1000ft (8.2 Ohm/km) |
| Electricals — Nom. Inner Shield DCR | 1.6 Ohm/1000ft (5.2 Ohm/km) |
| Electricals — Nom. Outer Shield DCR | 1.4 Ohm/1000ft (4.6 Ohm/km) |
| Attenuation Row 1 — Nom. Attenuation | 0.14 dB/100ft |
| Attenuation Row 2 — Nom. Attenuation | 0.3 dB/100ft |
| Attenuation Row 3 — Nom. Attenuation | 0.4 dB/100ft |
| Attenuation Row 4 — Nom. Attenuation | 1.1 dB/100ft |
| Attenuation Row 5 — Nom. Attenuation | 1.6 dB/100ft |
| Attenuation Row 6 — Nom. Attenuation | 2.3 dB/100ft |
| Attenuation Row 7 — Nom. Attenuation | 2.6 dB/100ft |
| Attenuation Row 8 — Nom. Attenuation | 3.3 dB/100ft |
| Attenuation Row 9 — Nom. Attenuation | 3.8 dB/100ft |
| Electricals — Nom. Velocity Of Prop. | 84% |
| Attenuation Row 10 — Nom. Attenuation | 4 dB/100ft |
| Attenuation Row 11 — Nom. Attenuation | 4.6 dB/100ft |
| Attenuation Row 12 — Nom. Attenuation | 5.9 dB/100ft |
| Attenuation Row 13 — Nom. Attenuation | 7.4 dB/100ft |
| Attenuation Row 14 — Nom. Attenuation | 12.5 dB/100ft |
| Electricals — Nom. Characteristic Impedance | 75 Ohm |
| Electricals — Nom. Capacitance Cond-to-Shield | 16.1 pF/ft (52.8 pF/m) |
| Return Loss Row 1 — Min. Structural Return Loss | 21 dB |
| Return Loss Row 2 — Min. Structural Return Loss | 15 dB |
Mechanical Characteristics
| Bulk Cable Weight | 113 lbs/1000ft (168 kg/km) |
| Max. Pull Tension | 170 lbs (77 kg) |
| Temperature — Operating | -55°C To +80°C |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing