Belden Store

Belden Cable

Belden|

MPN: 76033 TL005

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 76033 TL005.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
  • Conductor Element: Pair(s)
  • Conductor Size: 26 AWG
  • Conductor Stranding: 7x34
  • Conductor Material: TC - Tinned Copper
  • Conductor No. of Pairs: 4
  • Insulation Element: Pair(s)
  • Insulation Material: PE - Polyethylene
Belden 76033 TL005 is an orderable item number in the Belden 76033 family (Cable › Ethernet Cable › Industrial Ethernet Cable). XGIE, 4 Pair 26 AWG TC - Tinned Copper, Polyethylene, High Density Insulation, Overall Aluminum/Polyester Shield, Teal TPE Outer Jacket, CMR 75C, CMX-Outdoor 75C, SUN RES, AWM/STYLE 2463 80C, CSA C(UL) TYPE CMX-Outdoor C(UL) TYPE CMX-Outdoor This item: Color Teal, Putup Type Reel, Length 100 ft. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.6 Revision Date: 07-08-2026

This Item

ColorTeal
Length100 ft
Putup TypeReel
Item Number76033 TL005

Product Notes

NotesALPHA WIRE-A3 P/N 76033 HIGH FLEX CAT6A SF/UTP 4P 26AWG E163860 C(UL)US CMX-OUTDOOR - CMR 75C SUN RES OR AWM 2463 80C 600V OIL RES II CE ROHS (SEQ FOOTAGE)

Product Overview

Suitable ApplicationsData, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Construction Details

Conductor — Size26 AWG
Conductor — ElementPair(s)
Conductor — MaterialTC - Tinned Copper
Insulation — ElementPair(s)
Conductor — Stranding7x34
Insulation — MaterialPE - Polyethylene
Insulation — Color CodeWhite/Blue & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Outer Jacket — MaterialTPE - Thermoplastic Elastomer
Conductor — No. Of Pairs4
Outer Jacket — Nom. Diameter0.290 in (7.37 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Outer Shield Row 2 — Coverage75%
Outer Shield Row 2 — MaterialTinned Copper (TC)
Overall Cable Diameter (Nominal)0.290 in (7.37 mm)
Outer Shield Row 1 — Shield TypeTape
Outer Shield Row 2 — Shield TypeBraid
Insulation — Nom. Insulation Diameter0.034 in (0.86 mm)

Standards And Compliance

Data CategoryCategory 6A
AWM ComplianceAWM 2463
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ISO/IEC ComplianceISO/IEC 11801 Cat 6a
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
NEC / UL ComplianceArticle 800, CMR, CMX-Outdoor
CEC / C(UL) ComplianceCM, CMX-Outdoor.
UK Regulation ComplianceUKCA Mark
Environmental SuitabilityIndoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Oil Resistance
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL 1581 (Vertical Tray), (VW-1)

Electrical Characteristics

Electricals — ElementPair(s)
Delay — Max. Delay Skew45 ns/100m
Delay — Nom. Velocity Of Prop.68%
Electricals — Max. Conductor DCR212 Ohm/km (64.6 Ohm/1000ft)
High Frequency Row 1 — Min. ACR [DB]67.8
High Frequency Row 2 — Min. ACR [DB]55.8
High Frequency Row 3 — Min. ACR [DB]49.7
High Frequency Row 4 — Min. ACR [DB]47.8
High Frequency Row 5 — Min. ACR [DB]43.7
High Frequency Row 6 — Min. ACR [DB]41.8
High Frequency Row 7 — Min. ACR [DB]39.8
High Frequency Row 8 — Min. ACR [DB]37.9
High Frequency Row 9 — Min. ACR [DB]31.9
Electricals — Max. Mutual Capacitance56 pF/m (17 pF/ft)
High Frequency Row 1 — Min. NEXT [DB]74.3
High Frequency Row 10 — Min. ACR [DB]27.8
High Frequency Row 11 — Min. ACR [DB]21.8
High Frequency Row 12 — Min. ACR [DB]19.8
High Frequency Row 13 — Min. ACR [DB]18.3
High Frequency Row 14 — Min. ACR [DB]15.8
High Frequency Row 15 — Min. ACR [DB]13.8
High Frequency Row 2 — Min. NEXT [DB]65.3
High Frequency Row 3 — Min. NEXT [DB]60.8
High Frequency Row 4 — Min. NEXT [DB]59.3
High Frequency Row 5 — Min. NEXT [DB]56.2
High Frequency Row 6 — Min. NEXT [DB]54.8
High Frequency Row 7 — Min. NEXT [DB]53.3
High Frequency Row 8 — Min. NEXT [DB]51.9
High Frequency Row 9 — Min. NEXT [DB]47.4
High Frequency Row 1 — Frequency [MHz]1
High Frequency Row 10 — Min. NEXT [DB]44.3
High Frequency Row 11 — Min. NEXT [DB]39.8
High Frequency Row 12 — Min. NEXT [DB]38.3
High Frequency Row 13 — Min. NEXT [DB]37.1
High Frequency Row 14 — Min. NEXT [DB]35.3
High Frequency Row 15 — Min. NEXT [DB]33.8
High Frequency Row 2 — Frequency [MHz]4
High Frequency Row 3 — Frequency [MHz]8
High Frequency Row 4 — Frequency [MHz]10
High Frequency Row 5 — Frequency [MHz]16
High Frequency Row 6 — Frequency [MHz]20
High Frequency Row 7 — Frequency [MHz]25
High Frequency Row 8 — Frequency [MHz]31.25
High Frequency Row 9 — Frequency [MHz]62.5
High Frequency Row 1 — Min. PSNEXT [DB]72.3
High Frequency Row 10 — Frequency [MHz]100
High Frequency Row 11 — Frequency [MHz]200
High Frequency Row 12 — Frequency [MHz]250
High Frequency Row 13 — Frequency [MHz]300
High Frequency Row 14 — Frequency [MHz]400
High Frequency Row 15 — Frequency [MHz]500
High Frequency Row 2 — Min. PSNEXT [DB]63.3
High Frequency Row 3 — Min. PSNEXT [DB]58.8
High Frequency Row 4 — Min. PSNEXT [DB]57.3
High Frequency Row 5 — Min. PSNEXT [DB]54.3
High Frequency Row 6 — Min. PSNEXT [DB]52.8
High Frequency Row 7 — Min. PSNEXT [DB]51.4
High Frequency Row 8 — Min. PSNEXT [DB]49.9
High Frequency Row 9 — Min. PSNEXT [DB]45.4
Electricals — Max. Capacitance Unbalance330 pF/100m
High Frequency Row 10 — Min. PSNEXT [DB]42.3
High Frequency Row 11 — Min. PSNEXT [DB]37.8
High Frequency Row 12 — Min. PSNEXT [DB]36.3
High Frequency Row 13 — Min. PSNEXT [DB]35.1
High Frequency Row 14 — Min. PSNEXT [DB]33.3
High Frequency Row 15 — Min. PSNEXT [DB]31.8
Electricals — Nom. Characteristic Impedance100 Ohm
High Frequency Row 1 — Min. RL (Return Loss) [DB]20
High Frequency Row 2 — Min. RL (Return Loss) [DB]23
High Frequency Row 3 — Min. RL (Return Loss) [DB]24.5
High Frequency Row 4 — Min. RL (Return Loss) [DB]25
High Frequency Row 5 — Min. RL (Return Loss) [DB]25
High Frequency Row 6 — Min. RL (Return Loss) [DB]25
High Frequency Row 7 — Min. RL (Return Loss) [DB]24.2
High Frequency Row 8 — Min. RL (Return Loss) [DB]23.3
High Frequency Row 9 — Min. RL (Return Loss) [DB]21.7
High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB]64.8
High Frequency Row 10 — Min. RL (Return Loss) [DB]19
High Frequency Row 11 — Min. RL (Return Loss) [DB]16.4
High Frequency Row 12 — Min. RL (Return Loss) [DB]15.6
High Frequency Row 13 — Min. RL (Return Loss) [DB]14.9
High Frequency Row 14 — Min. RL (Return Loss) [DB]13.8
High Frequency Row 15 — Min. RL (Return Loss) [DB]13.0
High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB]52.8
High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB]46.7
High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB]44.8
High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB]40.7
High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB]38.8
High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB]36.8
High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB]34.9
High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB]28.9
High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB]24.8
High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB]18.8
High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB]16.8
High Frequency Row 13 — Min. PSACRF (PSELFEXT) [DB]15.3
High Frequency Row 14 — Min. PSACRF (PSELFEXT) [DB]12.8
High Frequency Row 15 — Min. PSACRF (PSELFEXT) [DB]10.8
High Frequency Row 1 — Max. Insertion Loss (Attenuation)3.1 dB/100m
High Frequency Row 2 — Max. Insertion Loss (Attenuation)5.7 dB/100m
High Frequency Row 3 — Max. Insertion Loss (Attenuation)8.0 dB/100m
High Frequency Row 4 — Max. Insertion Loss (Attenuation)8.9 dB/100m
High Frequency Row 5 — Max. Insertion Loss (Attenuation)11.2 dB/100m
High Frequency Row 6 — Max. Insertion Loss (Attenuation)12.6 dB/100m
High Frequency Row 7 — Max. Insertion Loss (Attenuation)14.1 dB/100m
High Frequency Row 8 — Max. Insertion Loss (Attenuation)15.8 dB/100m
High Frequency Row 9 — Max. Insertion Loss (Attenuation)22.5 dB/100m
High Frequency Row 10 — Max. Insertion Loss (Attenuation)28.7 dB/100m
High Frequency Row 11 — Max. Insertion Loss (Attenuation)41.4 dB/100m
High Frequency Row 12 — Max. Insertion Loss (Attenuation)46.6 dB/100m
High Frequency Row 13 — Max. Insertion Loss (Attenuation)51.4 dB/100m
High Frequency Row 14 — Max. Insertion Loss (Attenuation)60.1 dB/100m
High Frequency Row 15 — Max. Insertion Loss (Attenuation)67.9 dB/100m

Mechanical Characteristics

Bulk Cable Weight40.0 lbs/1000ft
Max. Pull Tension15.3 lbs (6.94 kg)
Temperature — Operating-40°C To +80°C
Temperature — UL Temperature80°C
Bend Radius — Stationary Min.1.2 in (30 mm)
Bend Radius — Installation Min.5.2 in (130 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account