Key Features
- Suitable Applications: PROFINET Cat6A, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.
- Conductor Size: 22 AWG
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor No. of Pairs: 4
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nom. Insulation Diameter: 1.60 mm (0.0630 in)
- Insulation Color Code: White & Blue, White & Orange, White & Green, White & Brown
Belden 74010EPE.00305 is an orderable item number in the Belden 74010EPE family (Cable › Ethernet Cable › Category 6A Cable). DataTuff® 6A, 4 Pair AWG 22 Bare Copper - Solid, Polyethylene insulation, S/FTP - Overall Braid / Individual Foil shielding, Polyethylene jacket , PROFINET Type A, Outdoor This item: Color Black, Putup Type Reel, Length 305 m, EAN 8719605177407. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.105 Revision Date: 02-20-2026 |
This Item
| EAN | 8719605177407 |
| Color | Black |
| Length | 305 m |
| Putup Type | Reel |
| Item Number | 74010EPE.00305 |
Product Overview
| Suitable Applications | PROFINET Cat6A, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. |
Construction Details
| Conductor — Size | 22 AWG |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Inner Shield — Coverage | 100% |
| Inner Shield — Material | Bi-Laminate (Alum+Poly) |
| Insulation — Color Code | White & Blue, White & Orange, White & Green, White & Brown |
| Outer Jacket — Material | PE - Polyethylene |
| Outer Shield — Coverage | 80% |
| Outer Shield — Material | Tinned Copper (TC) |
| Conductor — No. Of Pairs | 4 |
| Inner Shield — Shield Type | Tape |
| Outer Shield — Shield Type | Braid |
| Outer Jacket — Nom. Diameter | 8.7 mm (0.34 in) |
| Overall Cable Diameter (Nominal) | 8.7 mm (0.34 in) |
| Insulation — Nom. Insulation Diameter | 1.60 mm (0.0630 in) |
Standards And Compliance
| Data Category | Category 6A |
| CENELEC Compliance | Segregation class according EN50174-2 = d |
| ISO/IEC Compliance | ISO/IEC 11801-1 |
| Environmental Suitability | Outdoor |
| European Directive Compliance | EU CE Mark |
Electrical Characteristics
| Screening Class | Type I |
| Delay — Max. Delay Skew | 25 ns/100m |
| High Frequency Table Notes | Limits below 4MHz are for information only |
| Delay — Nom. Velocity Of Prop. | 78% |
| Electricals — Max. Conductor DCR | 59.1 Ohm/km (18.0 Ohm/1000ft) |
| High Frequency Row 1 — Min. ACR [DB] | 76 |
| High Frequency Row 2 — Min. ACR [DB] | 74.3 |
| High Frequency Row 3 — Min. ACR [DB] | 72.1 |
| High Frequency Row 4 — Min. ACR [DB] | 70.6 |
| High Frequency Row 5 — Min. ACR [DB] | 67.6 |
| High Frequency Row 6 — Min. ACR [DB] | 60.6 |
| High Frequency Row 7 — Min. ACR [DB] | 53.4 |
| High Frequency Row 8 — Min. ACR [DB] | 49.6 |
| High Frequency Row 9 — Min. ACR [DB] | 40.4 |
| Electricals — Max. Mutual Capacitance | 56 pF/m (17 pF/ft) |
| High Frequency Row 1 — Min. NEXT [DB] | 78 |
| High Frequency Row 10 — Min. ACR [DB] | 35.5 |
| High Frequency Row 11 — Min. ACR [DB] | 31.1 |
| High Frequency Row 12 — Min. ACR [DB] | 10.6 |
| High Frequency Row 2 — Min. NEXT [DB] | 78 |
| High Frequency Row 3 — Min. NEXT [DB] | 78 |
| High Frequency Row 4 — Min. NEXT [DB] | 78 |
| High Frequency Row 5 — Min. NEXT [DB] | 78 |
| High Frequency Row 6 — Min. NEXT [DB] | 75.5 |
| High Frequency Row 7 — Min. NEXT [DB] | 72.4 |
| High Frequency Row 8 — Min. NEXT [DB] | 70.9 |
| High Frequency Row 9 — Min. NEXT [DB] | 67.9 |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 1 — Min. PSACR [DB] | 73 |
| High Frequency Row 10 — Min. NEXT [DB] | 66.4 |
| High Frequency Row 11 — Min. NEXT [DB] | 65.2 |
| High Frequency Row 12 — Min. NEXT [DB] | 60.7 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 2 — Min. PSACR [DB] | 71.3 |
| High Frequency Row 3 — Frequency [MHz] | 10 |
| High Frequency Row 3 — Min. PSACR [DB] | 69.1 |
| High Frequency Row 4 — Frequency [MHz] | 16 |
| High Frequency Row 4 — Min. PSACR [DB] | 67.6 |
| High Frequency Row 5 — Frequency [MHz] | 31.2 |
| High Frequency Row 5 — Min. PSACR [DB] | 64.6 |
| High Frequency Row 6 — Frequency [MHz] | 62.5 |
| High Frequency Row 6 — Min. PSACR [DB] | 57.6 |
| High Frequency Row 7 — Frequency [MHz] | 100 |
| High Frequency Row 7 — Min. PSACR [DB] | 50.4 |
| High Frequency Row 8 — Frequency [MHz] | 125 |
| High Frequency Row 8 — Min. PSACR [DB] | 46.6 |
| High Frequency Row 9 — Frequency [MHz] | 200 |
| High Frequency Row 9 — Min. PSACR [DB] | 37.4 |
| High Frequency Row 1 — Min. ELTCTL [DB] | 35 |
| High Frequency Row 10 — Frequency [MHz] | 250 |
| High Frequency Row 10 — Min. PSACR [DB] | 32.5 |
| High Frequency Row 11 — Frequency [MHz] | 300 |
| High Frequency Row 11 — Min. PSACR [DB] | 28.1 |
| High Frequency Row 12 — Frequency [MHz] | 500 |
| High Frequency Row 12 — Min. PSACR [DB] | 7.6 |
| High Frequency Row 2 — Min. ELTCTL [DB] | 23 |
| High Frequency Row 3 — Min. ELTCTL [DB] | 15 |
| High Frequency Row 4 — Min. ELTCTL [DB] | 10.9 |
| High Frequency Row 5 — Min. ELTCTL [DB] | 5.1 |
| Electricals — Max. Capacitance Unbalance | 160 pF/100m |
| Electricals — Nom. Characteristic Impedance | 100 Ohm |
| High Frequency Row 1 — Min. ACRF (ELFEXT) [DB] | 78 |
| High Frequency Row 2 — Min. ACRF (ELFEXT) [DB] | 78 |
| High Frequency Row 3 — Min. ACRF (ELFEXT) [DB] | 75.3 |
| High Frequency Row 4 — Min. ACRF (ELFEXT) [DB] | 71.2 |
| High Frequency Row 5 — Min. ACRF (ELFEXT) [DB] | 65.4 |
| High Frequency Row 6 — Min. ACRF (ELFEXT) [DB] | 59.4 |
| High Frequency Row 7 — Min. ACRF (ELFEXT) [DB] | 55.3 |
| High Frequency Row 8 — Min. ACRF (ELFEXT) [DB] | 53.4 |
| High Frequency Row 9 — Min. ACRF (ELFEXT) [DB] | 49.3 |
| High Frequency Row 10 — Min. ACRF (ELFEXT) [DB] | 47.3 |
| High Frequency Row 11 — Min. ACRF (ELFEXT) [DB] | 45.8 |
| High Frequency Row 12 — Min. ACRF (ELFEXT) [DB] | 39.7 |
| High Frequency Row 1 — Min. RL (Return Loss) [DB] | 20 |
| High Frequency Row 2 — Min. RL (Return Loss) [DB] | 23 |
| High Frequency Row 3 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 4 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 5 — Min. RL (Return Loss) [DB] | 23.6 |
| High Frequency Row 6 — Min. RL (Return Loss) [DB] | 21.5 |
| High Frequency Row 7 — Min. RL (Return Loss) [DB] | 20.1 |
| High Frequency Row 8 — Min. RL (Return Loss) [DB] | 19.4 |
| High Frequency Row 9 — Min. RL (Return Loss) [DB] | 18 |
| High Frequency Row 10 — Min. RL (Return Loss) [DB] | 17.3 |
| High Frequency Row 11 — Min. RL (Return Loss) [DB] | 17.3 |
| High Frequency Row 12 — Min. RL (Return Loss) [DB] | 17.3 |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 2 dB/100m |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 3.7 dB/100m |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 5.9 dB/100m |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 7.4 dB/100m |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 10.4 dB/100m |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 14.9 dB/100m |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) | 19 dB/100m |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) | 21.4 dB/100m |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) | 27.5 dB/100m |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) | 31 dB/100m |
| High Frequency Row 11 — Max. Insertion Loss (Attenuation) | 34.2 dB/100m |
| High Frequency Row 12 — Max. Insertion Loss (Attenuation) | 50.1 dB/100m |
Mechanical Characteristics
| Temperature — Storage | -40°C to +80°C |
| Temperature — Operating | -40°C to +80°C |
| Temperature — Installation | 0°C To +60° |
| Bend Radius — Stationary Min. | 45 mm (1.8 in) |
| Bend Radius — Installation Min. | 90 mm |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing