Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 735C1 0085000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Central Office wiring for DS3 transmissions
- Conductor AWG: 25
- Conductor Stranding: Solid
- Conductor Material: SCCS - Silvered Copper Covered Steel
- Conductor Nominal Diameter: 0.017 in
- Conductor No. of Coax: 1
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nominal Diameter: 0.077 in
Belden 735C1 0085000 is an orderable item number in the Belden 735C1 family (Cable › Coax & Triax Cable › DS3 & DS4 Cable). 25H AWG solid .017" silver-plated copper conductors, foam HDPE insulation, Duobond® (100% coverage) plus a tinned copper braid shield (95% coverage), inner PVC jackets, overall PVC jacket This item: Color Gray, Put-Up Type Reel, Length 5,000 ft, UPC 612825184911. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.332 Revision Date: 02-20-2026 |
Standards
| RG Type | Mini 59 |
| NEC/(UL) Compliance | CMR |
| CEC/C(UL) Compliance | CMG |
This Item
| UPC | 612825184911 |
| Color | Gray |
| Length | 5,000 ft |
| Item Number | 735C1 0085000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
Product Overview
| Suitable Applications | Central Office wiring for DS3 transmissions |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Operating Temperature Range | -40°C To +75°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
Electrical Characteristics
| Delay — Nominal Delay | 1.29 ns/ft |
| Voltage — UL Voltage Rating | 300 V RMS |
| Return Loss — Frequency [MHz] | 5-150 MHz |
| Inductance — Nominal Inductance | 0.19 μH/ft |
| Return Loss — Minimum Return (RL) | 32 dB |
| Conductor DCR — Outer Conductor DCR | 5.3 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 40 Ohm/1000ft |
| High Frequency Row 1 — Frequency [MHz] | 5 MHz |
| High Frequency Row 2 — Frequency [MHz] | 10 MHz |
| High Frequency Row 3 — Frequency [MHz] | 22.5 MHz |
| High Frequency Row 4 — Frequency [MHz] | 50 MHz |
| High Frequency Row 5 — Frequency [MHz] | 100 MHz |
| High Frequency Row 6 — Frequency [MHz] | 150 MHz |
| Conductor DCR — Nominal Outer Shield DCR | 5.3 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 75 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 79% |
| Capacitance — Nom. Capacitance Conductor To Shield | 17.7 pF/ft |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 1.1 dB/100ft |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 1.5 dB/100ft |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 2.3 dB/100ft |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 3.4 dB/100ft |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 4.99 dB/100ft |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 6 dB/100ft |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 40 Ohm/1000ft |
Mechanical Characteristics
| Bulk Cable Weight | 13 lbs/1000ft |
| Min Bend Radius (Overall) | 1.5 in |
| Maximum Recommended Pulling Tension | 36 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 25 |
| Conductor — Material | SCCS - Silvered Copper Covered Steel |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Inner Shield Table Notes | Tape bonded to dielectric |
| Outer Jacket — Ripcord | Yes |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Inner Shield Row 1 — Type | Tape |
| Inner Shield Row 2 — Type | Braid |
| Inner Shield Row 1 — Layer | 1 |
| Inner Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.017 in |
| Inner Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Inner Shield Row 2 — Material | Tinned Copper (TC) |
| Insulation — Nominal Diameter | 0.077 in |
| Outer Jacket — Nominal Diameter | 0.134 in |
| Inner Shield Row 1 — Coverage [%] | 100% |
| Inner Shield Row 2 — Coverage [%] | 95% |
| Inner Shield Row 1 — Material Trade Name | Duobond® |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1666 Vertical Shaft |
| CSA Flammability | FT4 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| Environmental Space | Indoor - Riser |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing