Belden Store
Belden 735A6 0081000 — DS-3 and DS-4, 735* Series, #26-6 SPC Coax, CMR/CMG

Belden Cable

Belden|

MPN: 735A6 0081000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 735A6 0081000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Conductor AWG: 26
  • Conductor Stranding: Solid
  • Conductor Material: SCCS - Silvered Copper Covered Steel
  • Conductor Nominal Diameter: 0.016 in
  • Conductor No. of Coax: 6
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.077 in
  • Inner Jacket Material: PVC - Polyvinyl Chloride
Belden 735A6 0081000 is an orderable item number in the Belden 735A6 family (Cable › Coax & Triax Cable › DS3 & DS4 Cable). 26 AWG solid .016" silver-plated copper conductor(s), foam HDPE insulation, Beldfoil®; tinned copper braid shield (95% coverage), PVC jacket. This item: Color Gray, Put-Up Type Reel, Length 1,000 ft, UPC 612825184829. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.346 Revision Date: 02-20-2026

Standards

RG TypeMini 59
NEC/(UL) ComplianceCMR
CEC/C(UL) ComplianceCMG

This Item

UPC612825184829
ColorGray
Length1,000 ft
Item Number735A6 0081000
Put-Up TypeReel

Suitability

Suitability - IndoorYes

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

Operating Temperature Range-40°C To +75°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Nominal Delay1.34 ns/ft
Voltage — UL Voltage Rating300 V RMS
Return Loss — Frequency [MHz]15-95 MHz
Inductance — Nominal Inductance0.19 μH/ft
Return Loss — Minimum Return (RL)30 dB
Conductor DCR — Outer Conductor DCR5.3 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR41 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]1 MHz
High Frequency Row 2 — Frequency [MHz]1.024 MHz
High Frequency Row 3 — Frequency [MHz]4.224 MHz
High Frequency Row 4 — Frequency [MHz]5 MHz
High Frequency Row 5 — Frequency [MHz]10 MHz
High Frequency Row 6 — Frequency [MHz]17.184 MHz
High Frequency Row 7 — Frequency [MHz]22.368 MHz
High Frequency Row 8 — Frequency [MHz]25.92 MHz
High Frequency Row 9 — Frequency [MHz]44.736 MHz
High Frequency Row 10 — Frequency [MHz]50 MHz
High Frequency Row 11 — Frequency [MHz]69.632 MHz
High Frequency Row 12 — Frequency [MHz]77.76 MHz
High Frequency Row 13 — Frequency [MHz]100 MHz
High Frequency Row 14 — Frequency [MHz]137.088 MHz
High Frequency Row 15 — Frequency [MHz]200 MHz
Conductor DCR — Nominal Outer Shield DCR5.3 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]76%
Capacitance — Nom. Capacitance Conductor To Shield17.7 pF/ft
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.6 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)0.61 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)1.1 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)1.2 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)1.7 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)2.2 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)2.5 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)2.7 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)3.6 dB/100ft
High Frequency Row 10 — Max. Insertion Loss (Attenuation)3.8 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)4.5 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)4.8 dB/100ft
High Frequency Row 13 — Max. Insertion Loss (Attenuation)5.5 dB/100ft
High Frequency Row 14 — Max. Insertion Loss (Attenuation)6.4 dB/100ft
High Frequency Row 15 — Max. Insertion Loss (Attenuation)7.8 dB/100ft
Conductor DCR — Nominal Conductor DCR Conductor Resistance41 Ohm/1000ft

Mechanical Characteristics

Bulk Cable Weight89 lbs/1000ft
Min Bend Radius (Overall)4.5 in
Min Bend Radius (Each Coax)1.25 in
Maximum Recommended Pulling Tension150 lbs

Physical Characteristics (Overall)

Conductor Count6
Conductor — AWG26
Conductor — MaterialSCCS - Silvered Copper Covered Steel
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Jacket — RipcordYes
Conductor — No. Of Coax6
Inner Jacket — MaterialPVC - Polyvinyl Chloride
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialNo Shield
Inner Shield Row 1 — TypeTape
Inner Shield Row 2 — TypeBraid
Inner Shield Row 1 — Layer1
Inner Shield Row 2 — Layer2
Conductor — Nominal Diameter0.016 in
Inner Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 2 — MaterialTinned Copper (TC)
Insulation — Nominal Diameter0.077 in
Inner Jacket — Nominal Diameter0.129 in
Outer Jacket — Nominal Diameter0.435 in
Inner Shield Row 1 — Coverage [%]100%
Inner Shield Row 2 — Coverage [%]95%
Inner Shield Row 1 — Material Trade NameBeldfoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1666 Vertical Shaft
CSA FlammabilityFT4
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
Environmental SpaceIndoor - Riser
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account