Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 735A2 0081000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Conductor Size: 26
- Conductor Stranding: Solid
- Conductor Nom. Diameter: 0.016 in
- Conductor Material: SCCS - Silvered Copper Covered Steel
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nom. Insulation Diameter: 0.077 in (2.0 mm)
- Insulation Notes: HDPE
- Outer Jacket Material: PVC - Polyvinyl Chloride
Belden 735A2 0081000 is an orderable item number in the Belden 735A2 family (Cable › Coax & Triax Cable › DS3 & DS4 Cable). 26 AWG solid .016" silver-plated copper conductor(s), foam HDPE insulation, Beldfoil®; tinned copper braid shield (95% coverage), PVC jacket. (2) of these coax Siamese bonded in parallel. This item: Color Gray, Putup Type Reel, Length 1,000 ft, UPC 612825184775, Footnote C. Ships from and sold by A5 IT. Quoted to order.
History
| Footnote | C - CRATE REEL PUT-UP. |
| Update And Revision | Revision Number: 0.348 Revision Date: 07-30-2026 |
This Item
| UPC | 612825184775 |
| Color | Gray |
| Length | 1,000 ft |
| Footnote | C |
| Putup Type | Reel |
| Item Number | 735A2 0081000 |
Product Notes
| Notes | Each Coax Nominal Diameter: 0.129 in. Overall Nominal Diameter: 0.129 in x 0.258 in. Siamese version features zip cord design with printing on one leg. |
Product Life Cycle
| Life Cycle | Discontinued - the product is no longer manufactured |
| Discontinuation Announcement Date | 2020-05-01 |
Construction Details
| RG Type | Mini 59 |
| Conductor — Size | 26 |
| Insulation — Notes | HDPE |
| Conductor — Material | SCCS - Silvered Copper Covered Steel |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor — Nom. Diameter | 0.016 in |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Outer Jacket — Nom. Diameter | 0.129 in x 0.258 in |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Outer Shield Row 2 — Coverage | 95% |
| Outer Shield Row 2 — Material | Tinned Copper (TC) |
| Insulation — Nom. Insulation Diameter | 0.077 in (2.0 mm) |
| Outer Shield Row 1 — Outer Shield Type | Tape |
| Outer Shield Row 2 — Outer Shield Type | Braid |
| Outer Shield Row 1 — Material Trade Name | Beldfoil® |
Standards And Compliance
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| NEC / UL Compliance | CMR |
| CEC / C(UL) Compliance | CMG. |
| Environmental Suitability | Indoor - Riser, Indoor |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL1666 Vertical Shaft |
Electrical Characteristics
| Return Loss — Frequency | 15-95 MHz |
| Voltage — UL Voltage Rating | 300 V RMS |
| Return Loss — Min. Return Loss | 30 dB |
| Electricals — Nom. Conductor DCR | 41 Ohm/1000ft (130 Ohm/km) |
| Electricals — Nom. Outer Shield DCR | 5.3 Ohm/1000ft (17 Ohm/km) |
| Attenuation Row 1 — Max. Attenuation | 0.6 dB/100ft |
| Attenuation Row 2 — Max. Attenuation | 0.61 dB/100ft |
| Attenuation Row 3 — Max. Attenuation | 1.1 dB/100ft |
| Attenuation Row 4 — Max. Attenuation | 1.2 dB/100ft |
| Attenuation Row 5 — Max. Attenuation | 1.7 dB/100ft |
| Attenuation Row 6 — Max. Attenuation | 2.2 dB/100ft |
| Attenuation Row 7 — Max. Attenuation | 2.5 dB/100ft |
| Attenuation Row 8 — Max. Attenuation | 2.7 dB/100ft |
| Attenuation Row 9 — Max. Attenuation | 3.6 dB/100ft |
| Electricals — Nom. Velocity Of Prop. | 76% |
| Attenuation Row 10 — Max. Attenuation | 3.8 dB/100ft |
| Attenuation Row 11 — Max. Attenuation | 4.5 dB/100ft |
| Attenuation Row 12 — Max. Attenuation | 4.8 dB/100ft |
| Attenuation Row 13 — Max. Attenuation | 5.5 dB/100ft |
| Attenuation Row 14 — Max. Attenuation | 6.4 dB/100ft |
| Attenuation Row 15 — Max. Attenuation | 7.8 dB/100ft |
| Electricals — Nom. Characteristic Impedance | 75 Ohm |
| Electricals — Nom. Capacitance Cond-to-Shield | 17.7 pF/ft (58.1 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 23 lbs/1000ft (34 kg/km) |
| Max. Pull Tension | 50 lbs (23 kg) |
| Temperature — Operating | -40°C To +75°C |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing