Key Features
- Suitable Applications: Central Office wiring for DS3 transmissions.
- Conductor AWG: 20
- Conductor Stranding: Solid
- Conductor Material: SCCS - Silvered Copper Covered Steel
- Conductor Nominal Diameter: 0.032 in
- Conductor No. of Coax: 1
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nominal Diameter: 0.148 in
Belden 734C1 0085000 is an orderable item number in the Belden 734C1 family (Cable › Coax & Triax Cable › DS3 & DS4 Cable). 20 AWG solid .032" silver-plated copper conductors, gas-injected FHDPE insulation, Duobond®; tinned copper braid shield (85% coverage), inner PVC jacket, overall PVC jacket with ripcord. This item: Color Gray, Put-Up Type Reel, Length 5,000 ft, UPC 612825184256. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.337 Revision Date: 02-20-2026 |
Standards
| RG Type | 59 |
| NEC/(UL) Compliance | CMR |
| CEC/C(UL) Compliance | CMG |
This Item
| UPC | 612825184256 |
| Color | Gray |
| Length | 5,000 ft |
| Item Number | 734C1 0085000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Indoor | Yes |
Product Overview
| Suitable Applications | Central Office wiring for DS3 transmissions. |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
Temperature Range
| Operating Temperature Range | -40°C To +75°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
Electrical Characteristics
| Delay — Nominal Delay | 1.27 ns/ft |
| Voltage — UL Voltage Rating | 300 V RMS |
| Return Loss — Frequency [MHz] | 5-150 MHz |
| Inductance — Nominal Inductance | 0.097 μH/ft |
| Return Loss — Minimum Return (RL) | 32 dB |
| Conductor DCR — Outer Conductor DCR | 2.4 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 10 Ohm/1000ft |
| High Frequency Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency Row 2 — Frequency [MHz] | 5 MHz |
| High Frequency Row 3 — Frequency [MHz] | 10 MHz |
| High Frequency Row 4 — Frequency [MHz] | 22.5 MHz |
| High Frequency Row 5 — Frequency [MHz] | 50 MHz |
| High Frequency Row 6 — Frequency [MHz] | 100 MHz |
| High Frequency Row 7 — Frequency [MHz] | 150 MHz |
| Conductor DCR — Nominal Inner Shield DCR | 2.4 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 75 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 80% |
| Capacitance — Nom. Capacitance Conductor To Shield | 16.8 pF/ft |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) | 0.28 dB/100ft |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) | 0.59 dB/100ft |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) | 0.8 dB/100ft |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) | 1.18 dB/100ft |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) | 1.82 dB/100ft |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) | 2.6 dB/100ft |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) | 3.22 dB/100ft |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 10 Ohm/1000ft |
Mechanical Characteristics
| Bulk Cable Weight | 30 lbs/1000ft |
| Min Bend Radius (Overall) | 2.5 in |
| Maximum Recommended Pulling Tension | 60 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 20 |
| Conductor — Material | SCCS - Silvered Copper Covered Steel |
| Insulation Table Notes | Gas Injected |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Inner Shield Table Notes | Tape bonded to dielectric |
| Outer Jacket — Ripcord | Yes |
| Conductor — No. Of Coax | 1 |
| Inner Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield — Material | No Shield |
| Inner Shield Row 1 — Type | Tape |
| Inner Shield Row 2 — Type | Braid |
| Inner Shield Row 1 — Layer | 1 |
| Inner Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.032 in |
| Inner Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Inner Shield Row 2 — Material | Tinned Copper (TC) |
| Insulation — Nominal Diameter | 0.148 in |
| Inner Jacket — Nominal Diameter | 0.235 in |
| Outer Jacket — Nominal Diameter | 0.235 in |
| Inner Shield Row 1 — Coverage [%] | 100% |
| Inner Shield Row 2 — Coverage [%] | 85% |
| Inner Shield Row 1 — Material Trade Name | Duobond® |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1666 Vertical Shaft |
| CSA Flammability | FT4 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| Environmental Space | Indoor - Riser |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |