Key Features

  • Suitable Applications: Cat5e, harsh environment, IIoT, factory or process automation, video, audio, data communication, etc.
  • Conductor Size: 26 AWG
  • Conductor Stranding: 7x0.16 mm
  • Conductor Material: BC - Bare Copper
  • Conductor No. of Pairs: 2
  • Insulation Material: PE - Polyethylene
  • Insulation Nom. Insulation Diameter: 0.98 mm (0.039 in)
  • Insulation Color Code: White/Blue & Blue, White/Orange & Orange
Belden 72002PU.01305 is an orderable item number in the Belden 72002PU family (Cable › Ethernet Cable › Category 5e Cable). DataTuff® 5E, 2 Pair AWG 26 Bare Copper - Stranded, Polyethylene insulation, SF/UTP - Overall Braid + Foil shielding, PUR Halogen Free jacket , AWM 20549 This item: Color Black, Putup Type Reel, Length 305 m, EAN 8719605012852. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.264 Revision Date: 02-20-2026

This Item

EAN8719605012852
ColorBlack
Length305 m
Putup TypeReel
Item Number72002PU.01305

Product Overview

Suitable ApplicationsCat5e, harsh environment, IIoT, factory or process automation, video, audio, data communication, etc.

Construction Details

Conductor — Size26 AWG
Conductor — MaterialBC - Bare Copper
Conductor — Stranding7x0.16 mm
Insulation — MaterialPE - Polyethylene
Outer Shield Table NotesAluminum outside
Insulation — Color CodeWhite/Blue & Blue, White/Orange & Orange
Outer Jacket — MaterialPUR - Polyurethane (Halogen Free)
Outer Jacket1 Table NotesFlame Retardant Sheath
Cable Core — Description2 pairs and 2 fillers twisted to cable core covered with a polyester foil
Conductor — No. Of Pairs2
Outer Jacket — Nom. Diameter6 mm (0.24 in)
Outer Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Outer Shield Row 2 — Coverage80%
Outer Shield Row 2 — MaterialTinned Copper (TC)
Overall Cable Diameter (Nominal)6 mm (0.24 in)
Outer Shield Row 1 — Shield TypeTape
Outer Shield Row 2 — Shield TypeBraid
Insulation — Nom. Insulation Diameter0.98 mm (0.039 in)

Standards And Compliance

Data CategoryCategory 5e
AWM ComplianceAWM 20549
CENELEC ComplianceEN 50173-1
ISO/IEC ComplianceISO/IEC 11801-1
TIA/EIA ComplianceANSI/TIA 568.2-D
Environmental SuitabilityIndoor, Indoor, Sunlight Resistance, Oil Resistance
European Directive ComplianceEU CE Mark
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3

Electrical Characteristics

Screening ClassType I
Screening Table NotesCoupling Attenuation
Transfer Impedance ClassGrade 1
Delay — Max. Delay Skew40 ns/100m
Voltage — Voltage Rating450 V DC and 300 V AC
Voltage — UL Voltage Rating300 V
Delay — Nom. Velocity Of Prop.60%
Electricals — Max. Conductor DCR140 Ohm/km (43 Ohm/1000ft)
Transfer Impedance Row 1 — Frequency1 MHz
Transfer Impedance Row 2 — Frequency10 MHz
Transfer Impedance Row 3 — Frequency30 MHz
Transfer Impedance Row 4 — Frequency100 MHz
Electricals — Max. Mutual Capacitance56 pF/m (17 pF/ft)
High Frequency Row 1 — Min. NEXT [DB]67
High Frequency Row 2 — Min. NEXT [DB]65.3
High Frequency Row 3 — Min. NEXT [DB]56.3
High Frequency Row 4 — Min. NEXT [DB]50.3
High Frequency Row 5 — Min. NEXT [DB]47.2
High Frequency Row 6 — Min. NEXT [DB]45.8
High Frequency Row 7 — Min. NEXT [DB]44.3
High Frequency Row 8 — Min. NEXT [DB]42.9
High Frequency Row 9 — Min. NEXT [DB]38.3
High Frequency Row 1 — Frequency [MHz]0.772
High Frequency Row 10 — Min. NEXT [DB]35.3
High Frequency Row 2 — Frequency [MHz]1
High Frequency Row 3 — Frequency [MHz]4
High Frequency Row 4 — Frequency [MHz]10
High Frequency Row 5 — Frequency [MHz]16
High Frequency Row 6 — Frequency [MHz]20
High Frequency Row 7 — Frequency [MHz]25
High Frequency Row 8 — Frequency [MHz]31.25
High Frequency Row 9 — Frequency [MHz]62.5
High Frequency Row 10 — Frequency [MHz]100
Electricals — Max. Capacitance Unbalance160 pF/100m
Electricals — Nom. Characteristic Impedance100 Ohm
High Frequency Row 2 — Min. ACRF (ELFEXT) [DB]63.8
High Frequency Row 3 — Min. ACRF (ELFEXT) [DB]51.8
High Frequency Row 4 — Min. ACRF (ELFEXT) [DB]43.8
High Frequency Row 5 — Min. ACRF (ELFEXT) [DB]39.7
High Frequency Row 6 — Min. ACRF (ELFEXT) [DB]37.8
High Frequency Row 7 — Min. ACRF (ELFEXT) [DB]35.8
High Frequency Row 8 — Min. ACRF (ELFEXT) [DB]33.9
High Frequency Row 9 — Min. ACRF (ELFEXT) [DB]27.9
High Frequency Row 10 — Min. ACRF (ELFEXT) [DB]23.8
High Frequency Row 1 — Min. RL (Return Loss) [DB]19.4
High Frequency Row 2 — Min. RL (Return Loss) [DB]20
High Frequency Row 3 — Min. RL (Return Loss) [DB]23
High Frequency Row 4 — Min. RL (Return Loss) [DB]25
High Frequency Row 5 — Min. RL (Return Loss) [DB]25
High Frequency Row 6 — Min. RL (Return Loss) [DB]25
High Frequency Row 7 — Min. RL (Return Loss) [DB]24.3
High Frequency Row 8 — Min. RL (Return Loss) [DB]23.6
High Frequency Row 9 — Min. RL (Return Loss) [DB]21.5
High Frequency Row 10 — Min. RL (Return Loss) [DB]20.1
Transfer Impedance Row 1 — Max. Transfer ImpedanceMax. 15 mOhm/m
Transfer Impedance Row 2 — Max. Transfer ImpedanceMax. 10 mOhm/m
Transfer Impedance Row 3 — Max. Transfer ImpedanceMax. 30 mOhm/m
Transfer Impedance Row 4 — Max. Transfer Impedance100 mOhm/m
High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m]3.2
High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m]6
High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m]9.5
High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m]12.1
High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m]13.6
High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m]15.3
High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m]17.1
High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m]24.8
High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m]32

Mechanical Characteristics

Max. Pull Tension40 N (9.0 lbf)
Temperature — Storage-40°C To +80°C
Temperature — Operating-40°C to +80°C
Temperature — Installation-5°C To +50°C
Bend Radius — Stationary Min.25 mm (0.98 in)
Bend Radius — Installation Min.50 mm (2.0 in)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account