Belden 658GFS 0001000 — Access Control, 18c (#22-6pr, #18-4c, #22-2c), Shielded, CMP

Belden Cable

Belden|

MPN: 658GFS 0001000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 658GFS 0001000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Access Control, Security System, Power Limited Controls
  • Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
  • Outer Jacket Material: No Jacket
  • Voltage UL Voltage Rating: 300 V (CMP)
  • Temperature UL Temperature: 75°C
  • Temperature Operating: -5°C to +75°C
  • Temperature Installation: -5°C To +75°C
  • Bend Radius Stationary Min.: 4.56 in (116 mm)
Belden 658GFS 0001000 is an orderable item number in the Belden 658GFS family (Cable › Safety, Sound & Security › Access Control Cable). Access Control Cable, Plenum-CMP, 6-22 AWG pairs, 4-18 AWG conductors, 2-22 AWG conductors, All conductors stranded bare copper with Flamarrest® insulation, Each cable has overall Beldfoil® shield and Flamarrest® jacket, Banana Peel® No overall jacket This item: Color Orange, Yellow, White, Gray, Putup Type Reel, Length 1,000 ft, UPC 612825178644, Footnote C. Ships from and sold by A5 IT. Quoted to order.

History

FootnoteC - CRATE REEL PUT-UP.
Update And RevisionRevision Number: 0.612 Revision Date: 11-05-2025

This Item

UPC612825178644
ColorOrange, Yellow, White, Gray
Length1,000 ft
FootnoteC
Putup TypeReel
Item Number658GFS 0001000

Product Notes

NotesCold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation. Banana Peel® US PATENT 7049523.

Product Overview

PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
Suitable ApplicationsAccess Control, Security System, Power Limited Controls

Construction Details

Conductor Row 1 — Size22 AWG
Conductor Row 2 — Size22 AWG
Conductor Row 3 — Size22 AWG
Conductor Row 4 — Size18 AWG
Outer Jacket — MaterialNo Jacket
Outer Jacket1 Table NotesBanana Peel®
Conductor Row 1 — ElementPair(s)
Conductor Row 2 — ElementPair(s)
Conductor Row 3 — ElementConductor(s)
Conductor Row 4 — ElementConductor(s)
Conductor Row 1 — MaterialBC - Bare Copper
Conductor Row 2 — MaterialBC - Bare Copper
Conductor Row 3 — MaterialBC - Bare Copper
Conductor Row 4 — MaterialBC - Bare Copper
Inner Jacket Row 1 — ColorOrange
Inner Jacket Row 2 — ColorYellow
Inner Jacket Row 3 — ColorWhite
Inner Jacket Row 4 — ColorGray
Insulation Row 1 — ElementPair(s)
Insulation Row 2 — ElementPair(s)
Insulation Row 3 — ElementConductor(s)
Insulation Row 4 — ElementConductor(s)
Conductor Row 1 — Stranding7x30
Conductor Row 2 — Stranding7x30
Conductor Row 3 — Stranding7x30
Conductor Row 4 — Stranding7x26
Insulation Row 1 — MaterialPVC - Polyvinyl Chloride
Insulation Row 2 — MaterialPVC - Polyvinyl Chloride
Insulation Row 3 — MaterialPVC - Polyvinyl Chloride
Insulation Row 4 — MaterialPVC - Polyvinyl Chloride
Inner Jacket Row 1 — ElementPair(s)
Inner Jacket Row 1 — RipcordYes
Inner Jacket Row 2 — ElementPair(s)
Inner Jacket Row 2 — RipcordYes
Inner Jacket Row 3 — ElementConductor(s)
Inner Jacket Row 3 — RipcordYes
Inner Jacket Row 4 — ElementConductor(s)
Inner Jacket Row 4 — RipcordYes
Inner Shield Row 1 — ElementPair(s)
Inner Shield Row 2 — ElementPair(s)
Inner Shield Row 3 — ElementConductor(s)
Inner Shield Row 4 — ElementConductor(s)
Inner Jacket Row 1 — MaterialPVC - Polyvinyl Chloride
Inner Jacket Row 2 — MaterialPVC - Polyvinyl Chloride
Inner Jacket Row 3 — MaterialPVC - Polyvinyl Chloride
Inner Jacket Row 4 — MaterialPVC - Polyvinyl Chloride
Inner Shield Row 1 — Coverage100%
Inner Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 2 — Coverage100%
Inner Shield Row 2 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 3 — Coverage100%
Inner Shield Row 3 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 4 — Coverage100%
Inner Shield Row 4 — MaterialBi-Laminate (Alum+Poly)
Insulation Row 1 — Color CodeBlack & Red, White & Green, Brown & Orange
Insulation Row 2 — Color CodeBlack & Red, White & Green, Brown & Orange
Insulation Row 3 — Color CodeBlack, Red
Overall Cable Diameter (Nominal)0.456 in (11.6 mm)
Inner Shield Row 1 — Shield TypeTape
Inner Shield Row 2 — Shield TypeTape
Inner Shield Row 3 — Shield TypeTape
Inner Shield Row 4 — Shield TypeTape
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements3
Conductor Row 3 — No. Of Elements2
Conductor Row 4 — No. Of Elements4
Insulation Row 1 — Nom. Thickness0.009 in (0.23 mm)
Insulation Row 2 — Nom. Thickness0.009 in (0.23 mm)
Insulation Row 3 — Nom. Thickness0.009 in (0.23 mm)
Insulation Row 4 — Nom. Thickness0.010 in (0.25 mm)
Inner Jacket Row 1 — Nom. Diameter0.216 in (5.49 mm)
Inner Jacket Row 2 — Nom. Diameter0.216 in (5.49 mm)
Inner Jacket Row 3 — Nom. Diameter0.193 in (4.90 mm)
Inner Jacket Row 4 — Nom. Diameter0.193 in (4.90 mm)
Inner Jacket Row 1 — Nom. Thickness0.015 in (0.38 mm)
Inner Jacket Row 2 — Nom. Thickness0.015 in (0.38 mm)
Inner Jacket Row 3 — Nom. Thickness0.015 in (0.38 mm)
Inner Jacket Row 4 — Nom. Thickness0.015 in (0.38 mm)
Inner Shield Row 1 — Drainwire Type24 AWG (7x32) TC
Inner Shield Row 2 — Drainwire Type24 AWG (7x32) TC
Inner Shield Row 3 — Drainwire Type24 AWG (7x32) TC
Inner Shield Row 4 — Drainwire Type24 AWG (7x32) TC
Conductor Row 1 — Element DescriptionCard Reader
Conductor Row 2 — Element DescriptionCard Reader
Conductor Row 3 — Element DescriptionDoor Contact
Conductor Row 4 — Element DescriptionLock Power
Insulation Row 1 — Element DescriptionCard Reader
Insulation Row 2 — Element DescriptionCard Reader
Insulation Row 3 — Element DescriptionDoor Contact
Insulation Row 4 — Element DescriptionLock Power
Inner Jacket Row 1 — Element DescriptionCard Reader
Inner Jacket Row 2 — Element DescriptionCard Reader
Inner Jacket Row 3 — Element DescriptionDoor Contact
Inner Jacket Row 4 — Element DescriptionLock Power
Inner Shield Row 1 — Element DescriptionCard Reader
Inner Shield Row 2 — Element DescriptionCard Reader
Inner Shield Row 3 — Element DescriptionDoor Contact
Inner Shield Row 4 — Element DescriptionLock Power
Insulation Row 1 — Nom. Insulation Diameter0.047 in (1.2 mm)
Insulation Row 2 — Nom. Insulation Diameter0.047 in (1.2 mm)
Insulation Row 3 — Nom. Insulation Diameter0.047 in (1.2 mm)
Insulation Row 4 — Nom. Insulation Diameter0.066 in (1.7 mm)

Standards And Compliance

APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number558GFS
NEC / UL ComplianceArticle 800, CMP
CEC / C(UL) ComplianceCMP.
Environmental SuitabilityIndoor - Plenum, Indoor
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireNFPA 262, UL 910 (Plenum), FT6

Electrical Characteristics

Nom Outer Shield DCR6.92 Ohm/1000ft (22.7 Ohm/km)
Electricals Row 1 — ElementPair(s)
Electricals Row 2 — ElementPair(s)
Electricals Row 3 — ElementConductor(s)
Electricals Row 4 — ElementConductor(s)
Voltage — UL Voltage Rating300 V (CMP)
Electricals Row 1 — Max. Current2.2 Amps per Conductor at 25oC
Electricals Row 2 — Max. Current2.2 Amps per Conductor at 25oC
Electricals Row 3 — Max. Current2.2 Amps per Conductor at 25oC
Electricals Row 4 — Max. Current4 Amps per Conductor at 25oC
Electricals Row 1 — Nom. Conductor DCR16.3 Ohm/1000ft (53.5 Ohm/km)
Electricals Row 2 — Nom. Conductor DCR16.3 Ohm/1000ft (53.5 Ohm/km)
Electricals Row 3 — Nom. Conductor DCR16.4 Ohm/1000ft (53.8 Ohm/km)
Electricals Row 4 — Nom. Conductor DCR6.5 Ohm/1000ft (21 Ohm/km)
Electricals Row 1 — Element DescriptionCard Reader
Electricals Row 2 — Element DescriptionCard Reader
Electricals Row 3 — Element DescriptionDoor Contact
Electricals Row 4 — Element DescriptionLock Power
Electricals Row 1 — Nom. Inner Shield DCR16.19 Ohm/1000ft (53.12 Ohm/km)
Electricals Row 2 — Nom. Inner Shield DCR19.44 Ohm/1000ft (63.78 Ohm/km)
Electricals Row 3 — Nom. Inner Shield DCR16.19 Ohm/1000ft (53.12 Ohm/km)
Electricals Row 4 — Nom. Inner Shield DCR17.42 Ohm/1000ft (57.15 Ohm/km)
Electricals Row 1 — Nom. Capacitance Cond-to-Cond33 pF/ft (110 pF/m)
Electricals Row 2 — Nom. Capacitance Cond-to-Cond33 pF/ft (110 pF/m)
Electricals Row 3 — Nom. Capacitance Cond-to-Cond55 pF/ft (180 pF/m)
Electricals Row 4 — Nom. Capacitance Cond-to-Cond40 pF/ft (130 pF/m)
Electricals Row 1 — Nom. Capacitance Cond-to-Shield60 pF/ft (200 pF/m)
Electricals Row 2 — Nom. Capacitance Cond-to-Shield60 pF/ft (200 pF/m)
Electricals Row 3 — Nom. Capacitance Cond-to-Shield99 pF/ft (320 pF/m)
Electricals Row 4 — Nom. Capacitance Cond-to-Shield72 pF/ft (240 pF/m)

Mechanical Characteristics

Bulk Cable Weight105 lbs/1000ft (156 kg/km)
Max. Pull Tension148.7 lbs (67.45 kg)
Temperature — Operating-5°C to +75°C
Temperature — Installation-5°C To +75°C
Temperature — UL Temperature75°C
Bend Radius — Stationary Min.4.56 in (116 mm)
Bend Radius — Installation Min.4.56 in (116 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account