Key Features
- Suitable Applications: Access Control, Security System, Power Limited Controls
- Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
- Outer Jacket Material: No Jacket
- Voltage UL Voltage Rating: 300 V (CMP)
- Temperature UL Temperature: 75°C
- Temperature Operating: -5°C to +75°C
- Temperature Installation: -5°C To +75°C
- Bend Radius Stationary Min.: 4.56 in (116 mm)
Belden 658GFS 0001000 is an orderable item number in the Belden 658GFS family (Cable › Safety, Sound & Security › Access Control Cable). Access Control Cable, Plenum-CMP, 6-22 AWG pairs, 4-18 AWG conductors, 2-22 AWG conductors, All conductors stranded bare copper with Flamarrest® insulation, Each cable has overall Beldfoil® shield and Flamarrest® jacket, Banana Peel® No overall jacket This item: Color Orange, Yellow, White, Gray, Putup Type Reel, Length 1,000 ft, UPC 612825178644, Footnote C. Ships from and sold by A5 IT. Quoted to order.
History
| Footnote | C - CRATE REEL PUT-UP. |
| Update And Revision | Revision Number: 0.612 Revision Date: 11-05-2025 |
This Item
| UPC | 612825178644 |
| Color | Orange, Yellow, White, Gray |
| Length | 1,000 ft |
| Footnote | C |
| Putup Type | Reel |
| Item Number | 658GFS 0001000 |
Product Notes
| Notes | Cold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation. Banana Peel® US PATENT 7049523. |
Product Overview
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
| Suitable Applications | Access Control, Security System, Power Limited Controls |
Construction Details
| Conductor Row 1 — Size | 22 AWG |
| Conductor Row 2 — Size | 22 AWG |
| Conductor Row 3 — Size | 22 AWG |
| Conductor Row 4 — Size | 18 AWG |
| Outer Jacket — Material | No Jacket |
| Outer Jacket1 Table Notes | Banana Peel® |
| Conductor Row 1 — Element | Pair(s) |
| Conductor Row 2 — Element | Pair(s) |
| Conductor Row 3 — Element | Conductor(s) |
| Conductor Row 4 — Element | Conductor(s) |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Conductor Row 3 — Material | BC - Bare Copper |
| Conductor Row 4 — Material | BC - Bare Copper |
| Inner Jacket Row 1 — Color | Orange |
| Inner Jacket Row 2 — Color | Yellow |
| Inner Jacket Row 3 — Color | White |
| Inner Jacket Row 4 — Color | Gray |
| Insulation Row 1 — Element | Pair(s) |
| Insulation Row 2 — Element | Pair(s) |
| Insulation Row 3 — Element | Conductor(s) |
| Insulation Row 4 — Element | Conductor(s) |
| Conductor Row 1 — Stranding | 7x30 |
| Conductor Row 2 — Stranding | 7x30 |
| Conductor Row 3 — Stranding | 7x30 |
| Conductor Row 4 — Stranding | 7x26 |
| Insulation Row 1 — Material | PVC - Polyvinyl Chloride |
| Insulation Row 2 — Material | PVC - Polyvinyl Chloride |
| Insulation Row 3 — Material | PVC - Polyvinyl Chloride |
| Insulation Row 4 — Material | PVC - Polyvinyl Chloride |
| Inner Jacket Row 1 — Element | Pair(s) |
| Inner Jacket Row 1 — Ripcord | Yes |
| Inner Jacket Row 2 — Element | Pair(s) |
| Inner Jacket Row 2 — Ripcord | Yes |
| Inner Jacket Row 3 — Element | Conductor(s) |
| Inner Jacket Row 3 — Ripcord | Yes |
| Inner Jacket Row 4 — Element | Conductor(s) |
| Inner Jacket Row 4 — Ripcord | Yes |
| Inner Shield Row 1 — Element | Pair(s) |
| Inner Shield Row 2 — Element | Pair(s) |
| Inner Shield Row 3 — Element | Conductor(s) |
| Inner Shield Row 4 — Element | Conductor(s) |
| Inner Jacket Row 1 — Material | PVC - Polyvinyl Chloride |
| Inner Jacket Row 2 — Material | PVC - Polyvinyl Chloride |
| Inner Jacket Row 3 — Material | PVC - Polyvinyl Chloride |
| Inner Jacket Row 4 — Material | PVC - Polyvinyl Chloride |
| Inner Shield Row 1 — Coverage | 100% |
| Inner Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 2 — Coverage | 100% |
| Inner Shield Row 2 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 3 — Coverage | 100% |
| Inner Shield Row 3 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 4 — Coverage | 100% |
| Inner Shield Row 4 — Material | Bi-Laminate (Alum+Poly) |
| Insulation Row 1 — Color Code | Black & Red, White & Green, Brown & Orange |
| Insulation Row 2 — Color Code | Black & Red, White & Green, Brown & Orange |
| Insulation Row 3 — Color Code | Black, Red |
| Overall Cable Diameter (Nominal) | 0.456 in (11.6 mm) |
| Inner Shield Row 1 — Shield Type | Tape |
| Inner Shield Row 2 — Shield Type | Tape |
| Inner Shield Row 3 — Shield Type | Tape |
| Inner Shield Row 4 — Shield Type | Tape |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 3 |
| Conductor Row 3 — No. Of Elements | 2 |
| Conductor Row 4 — No. Of Elements | 4 |
| Insulation Row 1 — Nom. Thickness | 0.009 in (0.23 mm) |
| Insulation Row 2 — Nom. Thickness | 0.009 in (0.23 mm) |
| Insulation Row 3 — Nom. Thickness | 0.009 in (0.23 mm) |
| Insulation Row 4 — Nom. Thickness | 0.010 in (0.25 mm) |
| Inner Jacket Row 1 — Nom. Diameter | 0.216 in (5.49 mm) |
| Inner Jacket Row 2 — Nom. Diameter | 0.216 in (5.49 mm) |
| Inner Jacket Row 3 — Nom. Diameter | 0.193 in (4.90 mm) |
| Inner Jacket Row 4 — Nom. Diameter | 0.193 in (4.90 mm) |
| Inner Jacket Row 1 — Nom. Thickness | 0.015 in (0.38 mm) |
| Inner Jacket Row 2 — Nom. Thickness | 0.015 in (0.38 mm) |
| Inner Jacket Row 3 — Nom. Thickness | 0.015 in (0.38 mm) |
| Inner Jacket Row 4 — Nom. Thickness | 0.015 in (0.38 mm) |
| Inner Shield Row 1 — Drainwire Type | 24 AWG (7x32) TC |
| Inner Shield Row 2 — Drainwire Type | 24 AWG (7x32) TC |
| Inner Shield Row 3 — Drainwire Type | 24 AWG (7x32) TC |
| Inner Shield Row 4 — Drainwire Type | 24 AWG (7x32) TC |
| Conductor Row 1 — Element Description | Card Reader |
| Conductor Row 2 — Element Description | Card Reader |
| Conductor Row 3 — Element Description | Door Contact |
| Conductor Row 4 — Element Description | Lock Power |
| Insulation Row 1 — Element Description | Card Reader |
| Insulation Row 2 — Element Description | Card Reader |
| Insulation Row 3 — Element Description | Door Contact |
| Insulation Row 4 — Element Description | Lock Power |
| Inner Jacket Row 1 — Element Description | Card Reader |
| Inner Jacket Row 2 — Element Description | Card Reader |
| Inner Jacket Row 3 — Element Description | Door Contact |
| Inner Jacket Row 4 — Element Description | Lock Power |
| Inner Shield Row 1 — Element Description | Card Reader |
| Inner Shield Row 2 — Element Description | Card Reader |
| Inner Shield Row 3 — Element Description | Door Contact |
| Inner Shield Row 4 — Element Description | Lock Power |
| Insulation Row 1 — Nom. Insulation Diameter | 0.047 in (1.2 mm) |
| Insulation Row 2 — Nom. Insulation Diameter | 0.047 in (1.2 mm) |
| Insulation Row 3 — Nom. Insulation Diameter | 0.047 in (1.2 mm) |
| Insulation Row 4 — Nom. Insulation Diameter | 0.066 in (1.7 mm) |
Standards And Compliance
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum Number | 558GFS |
| NEC / UL Compliance | Article 800, CMP |
| CEC / C(UL) Compliance | CMP. |
| Environmental Suitability | Indoor - Plenum, Indoor |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | NFPA 262, UL 910 (Plenum), FT6 |
Electrical Characteristics
| Nom Outer Shield DCR | 6.92 Ohm/1000ft (22.7 Ohm/km) |
| Electricals Row 1 — Element | Pair(s) |
| Electricals Row 2 — Element | Pair(s) |
| Electricals Row 3 — Element | Conductor(s) |
| Electricals Row 4 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 300 V (CMP) |
| Electricals Row 1 — Max. Current | 2.2 Amps per Conductor at 25oC |
| Electricals Row 2 — Max. Current | 2.2 Amps per Conductor at 25oC |
| Electricals Row 3 — Max. Current | 2.2 Amps per Conductor at 25oC |
| Electricals Row 4 — Max. Current | 4 Amps per Conductor at 25oC |
| Electricals Row 1 — Nom. Conductor DCR | 16.3 Ohm/1000ft (53.5 Ohm/km) |
| Electricals Row 2 — Nom. Conductor DCR | 16.3 Ohm/1000ft (53.5 Ohm/km) |
| Electricals Row 3 — Nom. Conductor DCR | 16.4 Ohm/1000ft (53.8 Ohm/km) |
| Electricals Row 4 — Nom. Conductor DCR | 6.5 Ohm/1000ft (21 Ohm/km) |
| Electricals Row 1 — Element Description | Card Reader |
| Electricals Row 2 — Element Description | Card Reader |
| Electricals Row 3 — Element Description | Door Contact |
| Electricals Row 4 — Element Description | Lock Power |
| Electricals Row 1 — Nom. Inner Shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
| Electricals Row 2 — Nom. Inner Shield DCR | 19.44 Ohm/1000ft (63.78 Ohm/km) |
| Electricals Row 3 — Nom. Inner Shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
| Electricals Row 4 — Nom. Inner Shield DCR | 17.42 Ohm/1000ft (57.15 Ohm/km) |
| Electricals Row 1 — Nom. Capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Electricals Row 2 — Nom. Capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Electricals Row 3 — Nom. Capacitance Cond-to-Cond | 55 pF/ft (180 pF/m) |
| Electricals Row 4 — Nom. Capacitance Cond-to-Cond | 40 pF/ft (130 pF/m) |
| Electricals Row 1 — Nom. Capacitance Cond-to-Shield | 60 pF/ft (200 pF/m) |
| Electricals Row 2 — Nom. Capacitance Cond-to-Shield | 60 pF/ft (200 pF/m) |
| Electricals Row 3 — Nom. Capacitance Cond-to-Shield | 99 pF/ft (320 pF/m) |
| Electricals Row 4 — Nom. Capacitance Cond-to-Shield | 72 pF/ft (240 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 105 lbs/1000ft (156 kg/km) |
| Max. Pull Tension | 148.7 lbs (67.45 kg) |
| Temperature — Operating | -5°C to +75°C |
| Temperature — Installation | -5°C To +75°C |
| Temperature — UL Temperature | 75°C |
| Bend Radius — Stationary Min. | 4.56 in (116 mm) |
| Bend Radius — Installation Min. | 4.56 in (116 mm) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing