Key Features
- Suitable Applications: CATV, MATV
- Conductor AWG: 20
- Conductor Stranding: Solid
- Conductor Material: BC - Bare Copper
- Conductor Nominal Diameter: 0.032 in
- Conductor No. of Coax: 1
- Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
- Insulation Nominal Diameter: 0.133 in
Belden 6439C8 8771000 is an orderable item number in the Belden 6439C8 family (Cable › Video Cable › CATV Cable). Surveillance, CATV & MATV Cable, RG59, Plenum-CMP & CATVP, 20 AWG solid bare copper, foam FEP core, Duofoil® + 90% aluminum braid, Flamarrest® jacket This item: Color Natural, Put-Up Type Reel, Length 1,000 ft, UPC 612825176862. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.354 Revision Date: 02-20-2026 |
Standards
| RG Type | 59 |
| Series Type | 59 |
| NEC/(UL) Compliance | CATV, CMP |
| CEC/C(UL) Compliance | CMP |
This Item
| UPC | 612825176862 |
| Color | Natural |
| Length | 1,000 ft |
| Item Number | 6439C8 8771000 |
| Put-Up Type | Reel |
Suitability
| Suitability - Burial | No |
| Suitability - Indoor | Yes |
| Suitability - Hazardous Locations | No |
Product Notes
| Notes | Print legend includes sequential footage marks. |
Product Overview
| Suitable Applications | CATV, MATV |
Plenum/Non-Plenum
| Plenum (Y/N) | Yes |
Temperature Range
| UL Temperature Rating | 75°C |
| Operating Temperature Range | 0°C To +75°C |
Related Part Numbers
| Footnote | C - CRATE REEL PUT-UP. |
Electrical Characteristics
| Delay — Nominal Delay | 1.21 ns/ft |
| Delay — Max. Delay Skew | 83 ns/100m |
| Voltage — UL Voltage Rating | 300 V RMS |
| Inductance — Nominal Inductance | 0.097 μH/ft |
| Conductor DCR — Outer Conductor DCR | 5.5 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 10 Ohm/1000ft |
| Conductor DCR — Nominal Outer Shield DCR | 5.5 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 75 Ohm |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 84% |
| Capacitance — Nom. Capacitance Conductor To Shield | 16.3 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 50 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 100 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 200 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 400 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 700 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 900 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 1000 MHz |
| Conductor DCR — Nominal Conductor DCR Conductor Resistance | 10 Ohm/1000ft |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.4 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 0.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 1.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 2.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 3.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 5.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 7.6 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 8.8 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 9.4 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 20 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 2 in |
| Maximum Recommended Pulling Tension | 53 lbs |
Physical Characteristics (Overall)
| Conductor — AWG | 20 |
| Conductor — Material | BC - Bare Copper |
| Conductor — Stranding | Solid |
| Insulation — Material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Conductor — Nominal Diameter | 0.032 in |
| Insulation — Nominal Diameter | 0.133 in |
| Outer Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 2 — Material | Aluminum |
| Outer Jacket — Nominal Diameter | 0.199 in |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 90% |
| Outer Jacket — Material Trade Name | Flamarrest® |
| Outer Shield Row 1 — Material Trade Name | Duofoil® |
Flammability, LS0H, Toxicity Testing
| UL Flammability | NFPA 262 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU Directive Compliance | Yes |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing