Belden Store
Belden 6341PT 0011000 — Thermostat & Control, #18-2pr, TC, Indiv. Foil, CMP

Belden Cable

Belden|

MPN: 6341PT 0011000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 6341PT 0011000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Thermostat, Control, Noisy Environment
  • Conductor AWG: 18
  • Conductor Stranding: 7x26
  • Conductor Material: TC - Tinned Copper
  • Conductor No. of Pairs: 2
  • Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
  • Outer Shield Type: Tape
  • Outer Shield Material: Bi-Laminate (Alum+Poly)
Belden 6341PT 0011000 is an orderable item number in the Belden 6341PT family (Cable › Fieldbus Cable › RS-422 Cable). Thermostat & Control Cable, Plenum-CMP, 2-18 AWG stranded tinned copper pairs with foam FEP insulation, Individually Beldfoil® shielded and Flamarrest® jacket This item: Color Brown, UPC 612825176299. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.332 Revision Date: 02-03-2025

Standards

NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825176299
ColorBrown
Item Number6341PT 0011000

Product Overview

Suitable ApplicationsThermostat, Control, Noisy Environment

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range-20°C To +75°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.

Electrical Characteristics

Delay — Max. Delay Skew78 ns/100m
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.21 μH/ft
Conductor DCR — Nominal Conductor DCR6.6 Ohm/1000ft
Current — Max. Recommended Current [A]8.1 Amps per Conductor at 25oC
Delay — Nominal Velocity Of Propagation (VP) [%]78%
Capacitance — Nom. Capacitance Conductor To Conductor13.7 pF/ft
High Frequency — Max./Min. Input Impedance (UnFitted)100 ± 10 Ohm

Mechanical Characteristics

Bulk Cable Weight56 lbs/1000ft
Minimum Minor Axis Bend Radius2.8 in
Maximum Recommended Pulling Tension134 lbs

Physical Characteristics (Overall)

Conductor Count4
Conductor — AWG18
Outer Shield — TypeTape
Conductor — MaterialTC - Tinned Copper
Conductor — Stranding7x26
Insulation — MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialBi-Laminate (Alum+Poly)
Conductor — No. Of Pairs2
Color Chart Row 1 — ColorBlack & White
Color Chart Row 2 — ColorGreen & Red
Color Chart Row 1 — Number1
Color Chart Row 2 — Number2
Outer Shield — Coverage [%]100%
Outer Shield — Drainwire AWG18
Outer Jacket — Nominal Diameter0.28 in
Outer Shield — Drainwire MaterialTC - Tinned Copper
Outer Jacket — Material Trade NameFlamarrest®
Outer Shield — Material Trade NameBeldfoil®
Outer Shield — Drainwire Construction N X D7x26

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262 Plenum Flame Test (UL910)
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account