Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 6284UE 010500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Surveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom), UTP-CCTV
- Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
- Outer Shield Material: No Shield
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Material Trade Name: Flamarrest®
- Outer Jacket Nom. Diameter: 0.187 in
- Delay Max. Delay: 45 ns/ft
- Delay Max. Delay Skew: 70 ns/100m
Belden 6284UE 010500 is an orderable item number in the Belden 6284UE family (Cable › Coax & Triax Cable › CCTV & Security Cable). PTZ (Control + Power) Cable, Plenum-CMP, 2-23 AWG solid bare copper pairs with FEP insulation, 2-16 AWG stranded bare copper conductors with FEP insulation, Flamarrest® jacket This item: Color Black, UPC 612825174585, Footnote C. Ships from and sold by A5 IT. Quoted to order.
History
| Footnote | C - CRATE REEL PUT-UP. |
| Update And Revision | Revision Number: 0.344 Revision Date: 02-20-2026 |
This Item
| UPC | 612825174585 |
| Color | Black |
| Footnote | C |
| Item Number | 6284UE 010500 |
Product Notes
| Notes | Overall jacket sequentially marked. |
Product Overview
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
| Suitable Applications | Surveillance, CCTV Camera, PTZ (Pan-Tilt-Zoom), UTP-CCTV |
Construction Details
| Conductor Row 1 — Size | 23 |
| Conductor Row 2 — Size | 16 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield — Material | No Shield |
| Conductor Row 1 — Element | Cat 5e Pair |
| Conductor Row 2 — Element | Pair1 |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | TC - Tinned Copper |
| Insulation Row 1 — Element | Cat 5e Pair |
| Insulation Row 2 — Element | Pair1 |
| Conductor Row 1 — Stranding | Solid |
| Conductor Row 2 — Stranding | 19x29 |
| Insulation Row 1 — Material | FEP - Fluorinated Ethylene Propylene |
| Insulation Row 2 — Material | PVC - Polyvinyl Chloride |
| Inner Shield Row 1 — Element | Cat 5e Pair |
| Inner Shield Row 2 — Element | Pair1 |
| Outer Jacket — Nom. Diameter | 0.187 in |
| Inner Shield Row 1 — Material | No Shield |
| Inner Shield Row 2 — Material | No Shield |
| Insulation Row 1 — Color Code | Blue and White/Blue, Orange and White/Orange, Black & Red |
| Conductor Row 1 — No. Of Pairs | 2 |
| Outer Jacket — Material Trade Name | Flamarrest® |
| Insulation Row 1 — Nom. Insulation Diameter | 0.041 in (1.0 mm) |
| Insulation Row 2 — Nom. Insulation Diameter | 0.077 in (2.0 mm) |
Standards And Compliance
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum Number | 5284UE |
| ISO/IEC Compliance | ISO/IEC 11801, Category 5e for data pairs |
| NEC / UL Compliance | Article 800, CMP |
| CEC / C(UL) Compliance | CMP. |
| Environmental Suitability | Indoor - Plenum, Indoor |
| Other Standard Compliance(s) | ISO/IEC 11801, Category 5e |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | NFPA 262, FT6 |
Electrical Characteristics
| Delay — Max. Delay | 45 ns/ft |
| Delay — Max. Delay Skew | 70 ns/100m |
| Voltage — UL Voltage Rating | 300 V RMS |
| Delay — Nom. Velocity Of Prop. | 70% |
| Electricals Row 1 — Max. Conductor DCR | 27.432 Ohm/1000ft (90.000 Ohm/km) |
| Electricals Row 2 — Max. Conductor DCR | 14.7 Ohm/km (4.48 Ohm/1000ft) |
| High Frequency Row 1 — Frequency [MHz] | 1 |
| High Frequency Row 1 — Min. PSACR [DB] | 60 |
| High Frequency Row 2 — Frequency [MHz] | 4 |
| High Frequency Row 2 — Min. PSACR [DB] | 49 |
| High Frequency Row 3 — Frequency [MHz] | 8 |
| High Frequency Row 3 — Min. PSACR [DB] | 43 |
| High Frequency Row 4 — Frequency [MHz] | 10 |
| High Frequency Row 4 — Min. PSACR [DB] | 41 |
| High Frequency Row 5 — Frequency [MHz] | 16 |
| High Frequency Row 5 — Min. PSACR [DB] | 36 |
| High Frequency Row 6 — Frequency [MHz] | 20 |
| High Frequency Row 6 — Min. PSACR [DB] | 34 |
| High Frequency Row 7 — Frequency [MHz] | 25 |
| High Frequency Row 7 — Min. PSACR [DB] | 31 |
| High Frequency Row 8 — Frequency [MHz] | 31.25 |
| High Frequency Row 8 — Min. PSACR [DB] | 28 |
| High Frequency Row 9 — Frequency [MHz] | 62.5 |
| High Frequency Row 9 — Min. PSACR [DB] | 19 |
| High Frequency Row 1 — Min. PSNEXT [DB] | 62 |
| High Frequency Row 10 — Frequency [MHz] | 100 |
| High Frequency Row 10 — Min. PSACR [DB] | 11 |
| High Frequency Row 2 — Min. PSNEXT [DB] | 53 |
| High Frequency Row 3 — Min. PSNEXT [DB] | 48 |
| High Frequency Row 4 — Min. PSNEXT [DB] | 47 |
| High Frequency Row 5 — Min. PSNEXT [DB] | 44 |
| High Frequency Row 6 — Min. PSNEXT [DB] | 42 |
| High Frequency Row 7 — Min. PSNEXT [DB] | 41 |
| High Frequency Row 8 — Min. PSNEXT [DB] | 39 |
| High Frequency Row 9 — Min. PSNEXT [DB] | 35 |
| High Frequency Row 10 — Min. PSNEXT [DB] | 32 |
| Electricals Row 1 — Max. Capacitance Unbalance | 330 pF/ft |
| High Frequency Row 1 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 1 — Min. RL (Return Loss) [DB] | 20 |
| High Frequency Row 2 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 2 — Min. RL (Return Loss) [DB] | 23 |
| High Frequency Row 3 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 3 — Min. RL (Return Loss) [DB] | 24.5 |
| High Frequency Row 4 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 4 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 5 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 5 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 6 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 6 — Min. RL (Return Loss) [DB] | 25 |
| High Frequency Row 7 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 7 — Min. RL (Return Loss) [DB] | 24.3 |
| High Frequency Row 8 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 8 — Min. RL (Return Loss) [DB] | 23.6 |
| High Frequency Row 9 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 9 — Min. RL (Return Loss) [DB] | 21.5 |
| High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB] | 61 |
| High Frequency Row 10 — Max./Min. Fitted Impedance | 100 ± 15% |
| High Frequency Row 10 — Min. RL (Return Loss) [DB] | 20.1 |
| High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB] | 49 |
| High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB] | 43 |
| High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB] | 41 |
| High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB] | 37 |
| High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB] | 35 |
| High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB] | 33 |
| High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB] | 31 |
| High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB] | 24 |
| High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB] | 21 |
| High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m] | 2 |
| High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m] | 4.1 |
| High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m] | 5.8 |
| High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m] | 6.5 |
| High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m] | 8.2 |
| High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m] | 9.3 |
| High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m] | 10.4 |
| High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m] | 11.7 |
| High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m] | 17 |
| High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m] | 22 |
Mechanical Characteristics
| Bulk Cable Weight | 35 lbs/1000ft (52 kg/km) |
| Max. Pull Tension | 105 lbs (47.6 kg) |
| Temperature — Operating | -10°C To +75°C |
| Temperature — Installation | 0°C To +75°C |
| Temperature — UL Temperature | 75°C |