Key Features

  • Suitable Applications: Surveillance, CCTV Camera
  • Conductor AWG: 14
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.064 in
  • Conductor No. of Coax: 1
  • Insulation Material: FEP - Fluorinated Ethylene Propylene (Foam)
  • Insulation Nominal Diameter: 0.274 in
Belden 613948 0091000 is an orderable item number in the Belden 613948 family (Cable › Coax & Triax Cable › CCTV & Security Cable). Surveillance & CCTV Cable, RG11, Plenum-CMP, 14 AWG solid bare copper, foam FEP core, 95% bare copper braid, PVDF This item: Color White, Put-Up Type Reel, Length 1,000 ft, UPC 612825173823. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.408 Revision Date: 02-20-2026

Standards

RG Type11
Series Type11
NEC/(UL) ComplianceCMP
CEC/C(UL) ComplianceCMP

This Item

UPC612825173823
ColorWhite
Length1,000 ft
Item Number613948 0091000
Put-Up TypeReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Hazardous LocationsNo

Product Overview

Suitable ApplicationsSurveillance, CCTV Camera

Plenum/Non-Plenum

Plenum (Y/N)Yes

Temperature Range

UL Temperature Rating125°C
Operating Temperature Range-20°C To +125°C

Related Part Numbers

FootnoteC - CRATE REEL PUT-UP.
Non-Plenum Number513945

Electrical Characteristics

Delay — Nominal Delay1.22 ns/ft
Delay — Max. Delay Skew84 ns/100m
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.106 μH/ft
Mated Connection — Frequency (MHz)1
Conductor DCR — Outer Conductor DCR1.2 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR2.6 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR1.2 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.3 pF/ft
Unbalanced Crosstalk Row 1 — Typical Unbalanced FEXT %0.9 MHz
Unbalanced Crosstalk Row 2 — Typical Unbalanced NEXT %0.9 MHz
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance2.6 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.17 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.4 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss0.95 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss1.4 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss2.1 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss3.4 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss5 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss6 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss6.5 dB/100ft

Mechanical Characteristics

Bulk Cable Weight81 lbs/1000ft
Dimensions — Depth1
Dimensions — Width1
Dimensions — Height0.97
Minimum Minor Axis Bend Radius3.5 in
Maximum Recommended Pulling Tension138 lbs
Minimum Bend Radius During Installation0.9 in

Physical Characteristics (Overall)

Weight0.935 lbs
Conductor Count1
Conductor — AWG14
Outer Shield — TypeBraid
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialFEP - Fluorinated Ethylene Propylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVDF - Polyvinylidene Fluoride
Outer Shield — MaterialBare Copper (BC)
Outer Shield — Coverage [%]95%
Conductor — Nominal Diameter0.064 in
Insulation — Nominal Diameter0.274 in
Outer Jacket — Nominal Diameter0.348 in

Flammability, LS0H, Toxicity Testing

UL FlammabilityNFPA 262
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU Directive ComplianceYes
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account