Belden Store
Belden 558ANH 0001000 — Access Control, 16c (#22-3pr, #18-4c, #22-6c), Shielded, LSZH Banana Peel®, CMG-LS

Belden Cable

Belden|

MPN: 558ANH 0001000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 558ANH 0001000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Access Control, Security System, Power Limited Controls
  • Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
  • Outer Jacket Material: No Jacket
  • Outer Jacket Nom. Diameter: 0.493 in (12.5 mm)
  • Voltage UL Voltage Rating: 300 V
  • Temperature UL Temperature: 105°C
  • Temperature Operating: -20°C to +105°C
  • Bend Radius Stationary Min.: 4.93 in (125 mm)
Belden 558ANH 0001000 is an orderable item number in the Belden 558ANH family (Cable › Safety, Sound & Security › Access Control Cable). Access Control Cable, Riser-CMR, 3-22 AWG pairs, 4-18 AWG conductors, 4-22 AWG conductors, 2-22 AWG conductors, All conductors stranded bare copper with polyolefin insulation, Each cable has overall Beldfoil® shield and LSZH jacket, Banana Peel® No overall jacket This item: Color Orange, White, Blue, Gray, Putup Type Reel, Length 1,000 ft, UPC 612825164500. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.634 Revision Date: 11-05-2025

This Item

UPC612825164500
ColorOrange, White, Blue, Gray
Length1,000 ft
Putup TypeReel
Item Number558ANH 0001000

Product Notes

NotesCold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation.

Product Overview

PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
Suitable ApplicationsAccess Control, Security System, Power Limited Controls

Construction Details

Conductor Row 1 — Size22 AWG
Conductor Row 2 — Size22 AWG
Conductor Row 3 — Size22 AWG
Conductor Row 4 — Size18 AWG
Outer Jacket — MaterialNo Jacket
Outer Jacket1 Table NotesBanana Peel®
Conductor Row 1 — ElementPair(s)
Conductor Row 2 — ElementConductor(s)
Conductor Row 3 — ElementConductor(s)
Conductor Row 4 — ElementConductor(s)
Conductor Row 1 — MaterialBC - Bare Copper
Conductor Row 2 — MaterialBC - Bare Copper
Conductor Row 3 — MaterialBC - Bare Copper
Conductor Row 4 — MaterialBC - Bare Copper
Inner Jacket Row 1 — ColorOrange
Inner Jacket Row 2 — ColorWhite
Inner Jacket Row 3 — ColorBlue
Inner Jacket Row 4 — ColorGray
Insulation Row 1 — ElementPair(s)
Insulation Row 2 — ElementConductor(s)
Insulation Row 3 — ElementConductor(s)
Insulation Row 4 — ElementConductor(s)
Conductor Row 1 — Stranding7x30
Conductor Row 2 — Stranding7x30
Conductor Row 3 — Stranding7x30
Conductor Row 4 — Stranding7x26
Insulation Row 1 — MaterialPP - Polypropylene
Insulation Row 2 — MaterialPP - Polypropylene
Insulation Row 3 — MaterialPP - Polypropylene
Insulation Row 4 — MaterialPO - Polyolefin
Inner Jacket Row 1 — ElementPair(s)
Inner Jacket Row 1 — RipcordYes
Inner Jacket Row 2 — ElementConductor(s)
Inner Jacket Row 2 — RipcordYes
Inner Jacket Row 3 — ElementConductor(s)
Inner Jacket Row 3 — RipcordYes
Inner Jacket Row 4 — ElementConductor(s)
Inner Jacket Row 4 — RipcordYes
Inner Shield Row 1 — ElementPair(s)
Inner Shield Row 2 — ElementConductor(s)
Inner Shield Row 3 — ElementConductor(s)
Inner Shield Row 4 — ElementConductor(s)
Outer Jacket — Nom. Diameter0.493 in (12.5 mm)
Inner Jacket Row 1 — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Inner Jacket Row 2 — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Inner Jacket Row 3 — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Inner Jacket Row 4 — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Inner Shield Row 1 — Coverage100%
Inner Shield Row 1 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 2 — Coverage100%
Inner Shield Row 2 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 3 — Coverage100%
Inner Shield Row 3 — MaterialBi-Laminate (Alum+Poly)
Inner Shield Row 4 — Coverage100%
Inner Shield Row 4 — MaterialBi-Laminate (Alum+Poly)
Insulation Row 1 — Color CodeBlack & Red, White & Green, Brown & Orange
Insulation Row 2 — Color CodeBlack, Red
Insulation Row 3 — Color CodeBlack, Red, White, Green
Overall Cable Diameter (Nominal)0.493 in (12.5 mm)
Inner Shield Row 1 — Shield TypeTape
Inner Shield Row 2 — Shield TypeTape
Inner Shield Row 3 — Shield TypeTape
Inner Shield Row 4 — Shield TypeTape
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements2
Conductor Row 3 — No. Of Elements4
Conductor Row 4 — No. Of Elements4
Insulation Row 1 — Nom. Thickness0.0085 in (0.22 mm)
Insulation Row 2 — Nom. Thickness0.0085 in (0.22 mm)
Insulation Row 3 — Nom. Thickness0.0085 in (0.22 mm)
Insulation Row 4 — Nom. Thickness0.0085 in (0.22 mm)
Inner Jacket Row 1 — Nom. Diameter0.252 in (6.40 mm)
Inner Jacket Row 2 — Nom. Diameter0.165 in (4.19 mm)
Inner Jacket Row 3 — Nom. Diameter0.233 in (5.92 mm)
Inner Jacket Row 4 — Nom. Diameter0.233 in (5.92 mm)
Inner Jacket Row 1 — Nom. Thickness0.035 in (0.89 mm)
Inner Jacket Row 2 — Nom. Thickness0.035 in (0.89 mm)
Inner Jacket Row 3 — Nom. Thickness0.035 in (0.89 mm)
Inner Jacket Row 4 — Nom. Thickness0.035 in (0.89 mm)
Inner Shield Row 1 — Drainwire Type24 AWG (7x32) TC
Inner Shield Row 2 — Drainwire Type22 AWG (7x30) TC
Inner Shield Row 3 — Drainwire Type22 AWG (19x34) TC
Inner Shield Row 4 — Drainwire Type20 AWG (7x28) TC
Conductor Row 1 — Element DescriptionCard Reader
Conductor Row 2 — Element DescriptionDoor Contact
Conductor Row 3 — Element DescriptionREX/Spare
Conductor Row 4 — Element DescriptionLock Power
Insulation Row 1 — Element DescriptionCard Reader
Insulation Row 2 — Element DescriptionDoor Contact
Insulation Row 3 — Element DescriptionREX/Spare
Insulation Row 4 — Element DescriptionLock Power
Inner Jacket Row 1 — Element DescriptionCard Reader
Inner Jacket Row 2 — Element DescriptionDoor Contact
Inner Jacket Row 3 — Element DescriptionREX/Spare
Inner Jacket Row 4 — Element DescriptionLock Power
Inner Shield Row 1 — Element DescriptionCard Reader
Inner Shield Row 2 — Element DescriptionDoor Contact
Inner Shield Row 3 — Element DescriptionREX/Spare
Inner Shield Row 4 — Element DescriptionLock Power
Insulation Row 1 — Nom. Insulation Diameter0.045 in (1.1 mm)
Insulation Row 2 — Nom. Insulation Diameter0.045 in (1.1 mm)
Insulation Row 3 — Nom. Insulation Diameter0.045 in (1.1 mm)
Insulation Row 4 — Nom. Insulation Diameter0.062 in (1.6 mm)

Standards And Compliance

Plenum Number658AFS
CPR ComplianceCPR Euroclass: Eca
SustainabilityProduct LensTM, Environmental Product Declaration (EPD) Available
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Non-Plenum Number558ANH
NEC / UL ComplianceArticle 800, CMG-LS
CEC / C(UL) ComplianceCMG-LS.
UK Regulation ComplianceUKCA Mark
Environmental SuitabilityIndoor (Not Riser or Plenum), Indoor
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL 1685 FT4 Loading, Limited Smoke, FT4

Electrical Characteristics

Electricals Row 1 — ElementPair(s)
Electricals Row 2 — ElementConductor(s)
Electricals Row 3 — ElementConductor(s)
Electricals Row 4 — ElementConductor(s)
Voltage — UL Voltage Rating300 V
Electricals Row 1 — Max. Current4.2 Amps per Conductor @ 25°C
Electricals Row 2 — Max. Current6 Amps per Conductor at 25oC
Electricals Row 3 — Max. Current10.5 Amps per Conductor at 25oC
Electricals Row 4 — Max. Current11.2 Amps per Conductor at 25oC
Electricals Row 1 — Nom. Conductor DCR16.3 Ohm/1000ft (53.5 Ohm/km)
Electricals Row 2 — Nom. Conductor DCR16.4 Ohm/1000ft (53.8 Ohm/km)
Electricals Row 3 — Nom. Conductor DCR16.4 Ohm/1000ft (53.8 Ohm/km)
Electricals Row 4 — Nom. Conductor DCR6.5 Ohm/1000ft (21 Ohm/km)
Electricals Row 1 — Element DescriptionCard Reader
Electricals Row 2 — Element DescriptionDoor Contact
Electricals Row 3 — Element DescriptionREX/Spare
Electricals Row 4 — Element DescriptionLock Power
Electricals Row 1 — Nom. Inner Shield DCR13.9 Ohm/1000ft (45.6 Ohm/km)
Electricals Row 2 — Nom. Inner Shield DCR16.1 Ohm/1000ft (52.8 Ohm/km)
Electricals Row 3 — Nom. Inner Shield DCR16.1 Ohm/1000ft (52.8 Ohm/km)
Electricals Row 4 — Nom. Inner Shield DCR7.3 Ohm/1000ft (24 Ohm/km)
Electricals Row 1 — Nom. Capacitance Cond-to-Cond23 pF/ft (75 pF/m)
Electricals Row 2 — Nom. Capacitance Cond-to-Cond36 pF/ft (120 pF/m)
Electricals Row 3 — Nom. Capacitance Cond-to-Cond23 pF/ft (75 pF/m)
Electricals Row 4 — Nom. Capacitance Cond-to-Cond27 pF/ft (89 pF/m)
Electricals Row 1 — Nom. Capacitance Cond-to-Shield41 pF/ft (130 pF/m)
Electricals Row 2 — Nom. Capacitance Cond-to-Shield65 pF/ft (210 pF/m)
Electricals Row 3 — Nom. Capacitance Cond-to-Shield41 pF/ft (130 pF/m)
Electricals Row 4 — Nom. Capacitance Cond-to-Shield48.5 pF/ft (159 pF/m)

Mechanical Characteristics

Bulk Cable Weight153 lbs/1000ft (228 kg/km)
Max. Pull Tension200 lbs (91 kg)
Temperature — Operating-20°C to +105°C
Temperature — UL Temperature105°C
Bend Radius — Stationary Min.4.93 in (125 mm)
Bend Radius — Installation Min.4.93 in (125 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account

Documentation