Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 558ANH 0001000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Access Control, Security System, Power Limited Controls
- Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents .
- Outer Jacket Material: No Jacket
- Outer Jacket Nom. Diameter: 0.493 in (12.5 mm)
- Voltage UL Voltage Rating: 300 V
- Temperature UL Temperature: 105°C
- Temperature Operating: -20°C to +105°C
- Bend Radius Stationary Min.: 4.93 in (125 mm)
Belden 558ANH 0001000 is an orderable item number in the Belden 558ANH family (Cable › Safety, Sound & Security › Access Control Cable). Access Control Cable, Riser-CMR, 3-22 AWG pairs, 4-18 AWG conductors, 4-22 AWG conductors, 2-22 AWG conductors, All conductors stranded bare copper with polyolefin insulation, Each cable has overall Beldfoil® shield and LSZH jacket, Banana Peel® No overall jacket This item: Color Orange, White, Blue, Gray, Putup Type Reel, Length 1,000 ft, UPC 612825164500. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.634 Revision Date: 11-05-2025 |
This Item
| UPC | 612825164500 |
| Color | Orange, White, Blue, Gray |
| Length | 1,000 ft |
| Putup Type | Reel |
| Item Number | 558ANH 0001000 |
Product Notes
| Notes | Cold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation. |
Product Overview
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents . |
| Suitable Applications | Access Control, Security System, Power Limited Controls |
Construction Details
| Conductor Row 1 — Size | 22 AWG |
| Conductor Row 2 — Size | 22 AWG |
| Conductor Row 3 — Size | 22 AWG |
| Conductor Row 4 — Size | 18 AWG |
| Outer Jacket — Material | No Jacket |
| Outer Jacket1 Table Notes | Banana Peel® |
| Conductor Row 1 — Element | Pair(s) |
| Conductor Row 2 — Element | Conductor(s) |
| Conductor Row 3 — Element | Conductor(s) |
| Conductor Row 4 — Element | Conductor(s) |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Conductor Row 3 — Material | BC - Bare Copper |
| Conductor Row 4 — Material | BC - Bare Copper |
| Inner Jacket Row 1 — Color | Orange |
| Inner Jacket Row 2 — Color | White |
| Inner Jacket Row 3 — Color | Blue |
| Inner Jacket Row 4 — Color | Gray |
| Insulation Row 1 — Element | Pair(s) |
| Insulation Row 2 — Element | Conductor(s) |
| Insulation Row 3 — Element | Conductor(s) |
| Insulation Row 4 — Element | Conductor(s) |
| Conductor Row 1 — Stranding | 7x30 |
| Conductor Row 2 — Stranding | 7x30 |
| Conductor Row 3 — Stranding | 7x30 |
| Conductor Row 4 — Stranding | 7x26 |
| Insulation Row 1 — Material | PP - Polypropylene |
| Insulation Row 2 — Material | PP - Polypropylene |
| Insulation Row 3 — Material | PP - Polypropylene |
| Insulation Row 4 — Material | PO - Polyolefin |
| Inner Jacket Row 1 — Element | Pair(s) |
| Inner Jacket Row 1 — Ripcord | Yes |
| Inner Jacket Row 2 — Element | Conductor(s) |
| Inner Jacket Row 2 — Ripcord | Yes |
| Inner Jacket Row 3 — Element | Conductor(s) |
| Inner Jacket Row 3 — Ripcord | Yes |
| Inner Jacket Row 4 — Element | Conductor(s) |
| Inner Jacket Row 4 — Ripcord | Yes |
| Inner Shield Row 1 — Element | Pair(s) |
| Inner Shield Row 2 — Element | Conductor(s) |
| Inner Shield Row 3 — Element | Conductor(s) |
| Inner Shield Row 4 — Element | Conductor(s) |
| Outer Jacket — Nom. Diameter | 0.493 in (12.5 mm) |
| Inner Jacket Row 1 — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Inner Jacket Row 2 — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Inner Jacket Row 3 — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Inner Jacket Row 4 — Material | LSZH - Low Smoke Zero Halogen (Flame Retardant) |
| Inner Shield Row 1 — Coverage | 100% |
| Inner Shield Row 1 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 2 — Coverage | 100% |
| Inner Shield Row 2 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 3 — Coverage | 100% |
| Inner Shield Row 3 — Material | Bi-Laminate (Alum+Poly) |
| Inner Shield Row 4 — Coverage | 100% |
| Inner Shield Row 4 — Material | Bi-Laminate (Alum+Poly) |
| Insulation Row 1 — Color Code | Black & Red, White & Green, Brown & Orange |
| Insulation Row 2 — Color Code | Black, Red |
| Insulation Row 3 — Color Code | Black, Red, White, Green |
| Overall Cable Diameter (Nominal) | 0.493 in (12.5 mm) |
| Inner Shield Row 1 — Shield Type | Tape |
| Inner Shield Row 2 — Shield Type | Tape |
| Inner Shield Row 3 — Shield Type | Tape |
| Inner Shield Row 4 — Shield Type | Tape |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 2 |
| Conductor Row 3 — No. Of Elements | 4 |
| Conductor Row 4 — No. Of Elements | 4 |
| Insulation Row 1 — Nom. Thickness | 0.0085 in (0.22 mm) |
| Insulation Row 2 — Nom. Thickness | 0.0085 in (0.22 mm) |
| Insulation Row 3 — Nom. Thickness | 0.0085 in (0.22 mm) |
| Insulation Row 4 — Nom. Thickness | 0.0085 in (0.22 mm) |
| Inner Jacket Row 1 — Nom. Diameter | 0.252 in (6.40 mm) |
| Inner Jacket Row 2 — Nom. Diameter | 0.165 in (4.19 mm) |
| Inner Jacket Row 3 — Nom. Diameter | 0.233 in (5.92 mm) |
| Inner Jacket Row 4 — Nom. Diameter | 0.233 in (5.92 mm) |
| Inner Jacket Row 1 — Nom. Thickness | 0.035 in (0.89 mm) |
| Inner Jacket Row 2 — Nom. Thickness | 0.035 in (0.89 mm) |
| Inner Jacket Row 3 — Nom. Thickness | 0.035 in (0.89 mm) |
| Inner Jacket Row 4 — Nom. Thickness | 0.035 in (0.89 mm) |
| Inner Shield Row 1 — Drainwire Type | 24 AWG (7x32) TC |
| Inner Shield Row 2 — Drainwire Type | 22 AWG (7x30) TC |
| Inner Shield Row 3 — Drainwire Type | 22 AWG (19x34) TC |
| Inner Shield Row 4 — Drainwire Type | 20 AWG (7x28) TC |
| Conductor Row 1 — Element Description | Card Reader |
| Conductor Row 2 — Element Description | Door Contact |
| Conductor Row 3 — Element Description | REX/Spare |
| Conductor Row 4 — Element Description | Lock Power |
| Insulation Row 1 — Element Description | Card Reader |
| Insulation Row 2 — Element Description | Door Contact |
| Insulation Row 3 — Element Description | REX/Spare |
| Insulation Row 4 — Element Description | Lock Power |
| Inner Jacket Row 1 — Element Description | Card Reader |
| Inner Jacket Row 2 — Element Description | Door Contact |
| Inner Jacket Row 3 — Element Description | REX/Spare |
| Inner Jacket Row 4 — Element Description | Lock Power |
| Inner Shield Row 1 — Element Description | Card Reader |
| Inner Shield Row 2 — Element Description | Door Contact |
| Inner Shield Row 3 — Element Description | REX/Spare |
| Inner Shield Row 4 — Element Description | Lock Power |
| Insulation Row 1 — Nom. Insulation Diameter | 0.045 in (1.1 mm) |
| Insulation Row 2 — Nom. Insulation Diameter | 0.045 in (1.1 mm) |
| Insulation Row 3 — Nom. Insulation Diameter | 0.045 in (1.1 mm) |
| Insulation Row 4 — Nom. Insulation Diameter | 0.062 in (1.6 mm) |
Standards And Compliance
| Plenum Number | 658AFS |
| CPR Compliance | CPR Euroclass: Eca |
| Sustainability | Product LensTM, Environmental Product Declaration (EPD) Available |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum Number | 558ANH |
| NEC / UL Compliance | Article 800, CMG-LS |
| CEC / C(UL) Compliance | CMG-LS. |
| UK Regulation Compliance | UKCA Mark |
| Environmental Suitability | Indoor (Not Riser or Plenum), Indoor |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL 1685 FT4 Loading, Limited Smoke, FT4 |
Electrical Characteristics
| Electricals Row 1 — Element | Pair(s) |
| Electricals Row 2 — Element | Conductor(s) |
| Electricals Row 3 — Element | Conductor(s) |
| Electricals Row 4 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 300 V |
| Electricals Row 1 — Max. Current | 4.2 Amps per Conductor @ 25°C |
| Electricals Row 2 — Max. Current | 6 Amps per Conductor at 25oC |
| Electricals Row 3 — Max. Current | 10.5 Amps per Conductor at 25oC |
| Electricals Row 4 — Max. Current | 11.2 Amps per Conductor at 25oC |
| Electricals Row 1 — Nom. Conductor DCR | 16.3 Ohm/1000ft (53.5 Ohm/km) |
| Electricals Row 2 — Nom. Conductor DCR | 16.4 Ohm/1000ft (53.8 Ohm/km) |
| Electricals Row 3 — Nom. Conductor DCR | 16.4 Ohm/1000ft (53.8 Ohm/km) |
| Electricals Row 4 — Nom. Conductor DCR | 6.5 Ohm/1000ft (21 Ohm/km) |
| Electricals Row 1 — Element Description | Card Reader |
| Electricals Row 2 — Element Description | Door Contact |
| Electricals Row 3 — Element Description | REX/Spare |
| Electricals Row 4 — Element Description | Lock Power |
| Electricals Row 1 — Nom. Inner Shield DCR | 13.9 Ohm/1000ft (45.6 Ohm/km) |
| Electricals Row 2 — Nom. Inner Shield DCR | 16.1 Ohm/1000ft (52.8 Ohm/km) |
| Electricals Row 3 — Nom. Inner Shield DCR | 16.1 Ohm/1000ft (52.8 Ohm/km) |
| Electricals Row 4 — Nom. Inner Shield DCR | 7.3 Ohm/1000ft (24 Ohm/km) |
| Electricals Row 1 — Nom. Capacitance Cond-to-Cond | 23 pF/ft (75 pF/m) |
| Electricals Row 2 — Nom. Capacitance Cond-to-Cond | 36 pF/ft (120 pF/m) |
| Electricals Row 3 — Nom. Capacitance Cond-to-Cond | 23 pF/ft (75 pF/m) |
| Electricals Row 4 — Nom. Capacitance Cond-to-Cond | 27 pF/ft (89 pF/m) |
| Electricals Row 1 — Nom. Capacitance Cond-to-Shield | 41 pF/ft (130 pF/m) |
| Electricals Row 2 — Nom. Capacitance Cond-to-Shield | 65 pF/ft (210 pF/m) |
| Electricals Row 3 — Nom. Capacitance Cond-to-Shield | 41 pF/ft (130 pF/m) |
| Electricals Row 4 — Nom. Capacitance Cond-to-Shield | 48.5 pF/ft (159 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 153 lbs/1000ft (228 kg/km) |
| Max. Pull Tension | 200 lbs (91 kg) |
| Temperature — Operating | -20°C to +105°C |
| Temperature — UL Temperature | 105°C |
| Bend Radius — Stationary Min. | 4.93 in (125 mm) |
| Bend Radius — Installation Min. | 4.93 in (125 mm) |