Belden Store
Belden 551945 0101000 — Surveillance CCTV, RG-59 #22 BC, 93% BC Braid, CM

Belden Cable

Belden|

MPN: 551945 0101000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 551945 0101000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Surveillance, CCTV Camera
  • Conductor AWG: 22
  • Conductor Stranding: 7x30
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.03 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.14 in
Belden 551945 0101000 is an orderable item number in the Belden 551945 family (Cable › Coax & Triax Cable › CCTV & Security Cable). Surveillance & CCTV Cable, RG59, Rated-CM, 22 AWG stranded bare copper, foam polyolefin core, 93% bare copper braid, PVC jacket This item: Color Black, Put-Up Type Reel, Length 1,000 ft, UPC 612825163992. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.397 Revision Date: 03-27-2024

Standards

RG Type59
Series Type59
NEC ArticlesArticle 800
NEC/(UL) ComplianceCM
CEC/C(UL) ComplianceCM

This Item

UPC612825163992
ColorBlack
Length1,000 ft
Item Number551945 0101000
Put-Up TypeReel

Suitability

Suitability - IndoorYes
Suitability - OutdoorYes

Product Overview

Suitable ApplicationsSurveillance, CCTV Camera

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range-40°C To +75°C

Electrical Characteristics

Delay — Nominal Delay1.3 ns/ft
Delay — Max. Delay Skew78 ns/100m
Voltage — UL Voltage Rating300 V RMS
Inductance — Nominal Inductance0.09 μH/ft
Conductor DCR — Outer Conductor DCR2.6 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR15 Ohm/1000ft
Conductor DCR — Nominal Outer Shield DCR2.6 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Delay — Nominal Velocity Of Propagation (VP) [%]78%
Capacitance — Nom. Capacitance Conductor To Shield17.3 pF/ft
High Frequency (Nominal/Typical) Row 1 — Frequency [MHz]1 MHz
High Frequency (Nominal/Typical) Row 2 — Frequency [MHz]10 MHz
High Frequency (Nominal/Typical) Row 3 — Frequency [MHz]50 MHz
High Frequency (Nominal/Typical) Row 4 — Frequency [MHz]100 MHz
High Frequency (Nominal/Typical) Row 5 — Frequency [MHz]200 MHz
High Frequency (Nominal/Typical) Row 6 — Frequency [MHz]400 MHz
High Frequency (Nominal/Typical) Row 7 — Frequency [MHz]700 MHz
High Frequency (Nominal/Typical) Row 8 — Frequency [MHz]900 MHz
High Frequency (Nominal/Typical) Row 9 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Conductor DCR Conductor Resistance15 Ohm/1000ft
High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss0.3 dB/100ft
High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss0.9 dB/100ft
High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss2.1 dB/100ft
High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss3 dB/100ft
High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss4.5 dB/100ft
High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss6.6 dB/100ft
High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss8.9 dB/100ft
High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss10.1 dB/100ft
High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss10.9 dB/100ft

Mechanical Characteristics

Bulk Cable Weight28 lbs/1000ft
Dimensions — Depth0.79
Dimensions — Width0.76
Minimum Minor Axis Bend Radius2.5 in
Maximum Recommended Pulling Tension49 lbs

Physical Characteristics (Overall)

Conductor — AWG22
Outer Shield — TypeBraid
Conductor — MaterialBC - Bare Copper
Insulation Table NotesGas Injected
Conductor — Stranding7x30
Insulation — MaterialPE - Polyethylene (Foam)
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield — MaterialBare Copper (BC)
Outer Shield — Coverage [%]93%
Conductor — Nominal Diameter0.03 in
Insulation — Nominal Diameter0.14 in
Outer Jacket — Nominal Diameter0.232 in

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
UL Voltage Rating300 V RMS

Applicable Environmental And Other Programs

EU CE MarkYes
EU Directive ComplianceYes
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account