  • Suitable Applications: CATV, MATV, Schlage Systems
  • Conductor AWG: 18
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor Nominal Diameter: 0.040 in
  • Conductor No. of Coax: 1
  • Insulation Material: PE - Polyethylene (Foam)
  • Insulation Nominal Diameter: 0.180 in
Belden 5399B5 010U1000 is an orderable item number in the Belden 5399B5 family (Cable › Video Cable › CATV Cable). Surveillance, CATV & MATV Cable, RG6, Rated-CM & CL2,18 AWG solid bare copper, foam polyolefin core, Duobond® + 60% aluminum braid, PVC jacket This item: Color Black, Put-Up Type UnReel, Length 1,000 ft, UPC 612825161837. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.373 Revision Date: 02-20-2026

Standards

RG Type6
NEC/(UL) ComplianceCL2, CM
CEC/C(UL) ComplianceCM

This Item

UPC612825161837
ColorBlack
Length1,000 ft
Item Number5399B5 010U1000
Put-Up TypeUnReel

Suitability

Suitability - AerialYes - When supported by messenger wire
Suitability - BurialNo
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Hazardous LocationsNo

Product Notes

NotesPrint legend includes sequential footage marks.

Product Overview

Suitable ApplicationsCATV, MATV, Schlage Systems

Plenum/Non-Plenum

Plenum (Y/N)No

Temperature Range

UL Temperature Rating75°C
Operating Temperature Range-40°C To +80°C

Electrical Characteristics

Delay — Nominal Delay1.22 ns/ft
Delay — Max. Delay Skew83 ns/100m
Voltage — UL Voltage Rating300 V RMS
Return Loss — Frequency [MHz]5-50 MHz
Inductance — Nominal Inductance0.097 μH/ft
Conductor DCR — Outer Conductor DCR9.0 Ohm/1000ft
Conductor DCR — Nominal Conductor DCR6.5 Ohm/1000ft
High Frequency Row 1 — Frequency [MHz]4 MHz
High Frequency Row 2 — Frequency [MHz]30 MHz
High Frequency Row 3 — Frequency [MHz]211 MHz
High Frequency Row 4 — Frequency [MHz]270 MHz
High Frequency Row 5 — Frequency [MHz]300 MHz
High Frequency Row 6 — Frequency [MHz]330 MHz
High Frequency Row 7 — Frequency [MHz]400 MHz
High Frequency Row 8 — Frequency [MHz]450 MHz
High Frequency Row 9 — Frequency [MHz]550 MHz
High Frequency Row 10 — Frequency [MHz]750 MHz
High Frequency Row 11 — Frequency [MHz]870 MHz
High Frequency Row 12 — Frequency [MHz]1000 MHz
Conductor DCR — Nominal Outer Shield DCR9 Ohm/1000ft
Impedance — Nominal Characteristic Impedance75 Ohm
Return Loss — Min. Structural Return Loss (SRL)23 dB
Delay — Nominal Velocity Of Propagation (VP) [%]83%
Capacitance — Nom. Capacitance Conductor To Shield16.3 pF/ft
High Frequency Row 1 — Max. Insertion Loss (Attenuation)0.6 dB/100ft
High Frequency Row 2 — Max. Insertion Loss (Attenuation)1.33 dB/100ft
High Frequency Row 3 — Max. Insertion Loss (Attenuation)3.08 dB/100ft
High Frequency Row 4 — Max. Insertion Loss (Attenuation)3.5 dB/100ft
High Frequency Row 5 — Max. Insertion Loss (Attenuation)3.7 dB/100ft
High Frequency Row 6 — Max. Insertion Loss (Attenuation)3.89 dB/100ft
High Frequency Row 7 — Max. Insertion Loss (Attenuation)4.3 dB/100ft
High Frequency Row 8 — Max. Insertion Loss (Attenuation)4.58 dB/100ft
High Frequency Row 9 — Max. Insertion Loss (Attenuation)5.09 dB/100ft
High Frequency Row 10 — Max. Insertion Loss (Attenuation)6 dB/100ft
High Frequency Row 11 — Max. Insertion Loss (Attenuation)6.5 dB/100ft
High Frequency Row 12 — Max. Insertion Loss (Attenuation)7 dB/100ft
Conductor DCR — Nominal Conductor DCR Conductor Resistance6.5 Ohm/1000ft

Mechanical Characteristics

Bulk Cable Weight27 lbs/1000ft
Minimum Minor Axis Bend Radius2.7 in
Maximum Recommended Pulling Tension50 lbs

Physical Characteristics (Overall)

Conductor Count1
Conductor — AWG18
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialPE - Polyethylene (Foam)
Outer Shield Table NotesTape is bonded to dielectric
Conductor — No. Of Coax1
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Outer Shield Row 1 — TypeTape
Outer Shield Row 2 — TypeBraid
Outer Shield Row 1 — Layer1
Outer Shield Row 2 — Layer2
Conductor — Nominal Diameter0.040 in
Insulation — Nominal Diameter0.180 in
Outer Shield Row 1 — MaterialTri-Laminate (Alum+Poly+Alum)
Outer Shield Row 2 — MaterialAluminum
Outer Jacket — Nominal Diameter0.270 in
Outer Shield Row 1 — Coverage [%]100%
Outer Shield Row 2 — Coverage [%]60%
Outer Shield Row 1 — Material Trade NameDuofoil®

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL1685 UL Loading
UL Voltage Rating350 V RMS

Applicable Environmental And Other Programs

EU Directive ComplianceYes
MII Order #39 (China RoHSYes
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/11/EC (BFR)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2011/65/EU RoHS 2)Yes
EU Directive 2015/863/EU RoHS 2 Amendment)Yes

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account