Belden Store
Belden 50106FLS-A500 — CAT 6 4P23AWG, F/UTP, SWA, LSZH Jkt, Indoor/Outdoor

Belden Cable

Belden|

MPN: 50106FLS-A500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 50106FLS-A500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Industrial Ethernet cables are used for interconnecting Industrial Ethernet Switches, IP controllers, media convertors, distributed control system, programmable logic controller and transmitting industrial protocol data signals. These cables are suitable for transmitting 1000BASE-TX Gigabit Ethernet, 100BASE-T Ethernet, 100BaseVG ANYLAN, 155ATM, 622ATM, RS-422, 250MHz Category 6, EtherCAT. These are highly durable & ruggedized cables for both indoor and outdoor use meeting IEC 60332-3-24 and IEC 60754-1 & 2
  • Conductor Size: 23 AWG
  • Conductor Stranding: Solid
  • Conductor Material: BC - Bare Copper
  • Conductor No. of Pairs: 4
  • Insulation Material: PO - Polyolefin
  • Insulation Nom. Insulation Diameter: 1.10 mm (0.0433 in)
  • Insulation Color Code: Blue & White with Blue Markings, Orange & White with Orange Markings, Green & White with Green Markings, Brown & White with Brown Markings
Belden 50106FLS-A500 is an orderable item number in the Belden 50106FLS family (Cable › Ethernet Cable › Industrial Ethernet Cable). CAT 6 4PR x 23AWG F/UTP, Solid Bare Copper Conductor, PO Insulation, Overall Foil Shield, LSZH Inner Jacket, Steel Wire Armoring, LSZH Outer Jacket, Indoor/Outdoor This item: Color Black, Putup Type Reel, Length 500 m. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.92 Revision Date: 02-20-2026

This Item

ColorBlack
Length500 m
Putup TypeReel
Item Number50106FLS-A500

Product Overview

Suitable ApplicationsIndustrial Ethernet cables are used for interconnecting Industrial Ethernet Switches, IP controllers, media convertors, distributed control system, programmable logic controller and transmitting industrial protocol data signals. These cables are suitable for transmitting 1000BASE-TX Gigabit Ethernet, 100BASE-T Ethernet, 100BaseVG ANYLAN, 155ATM, 622ATM, RS-422, 250MHz Category 6, EtherCAT. These are highly durable & ruggedized cables for both indoor and outdoor use meeting IEC 60332-3-24 and IEC 60754-1 & 2

Construction Details

Conductor — Size23 AWG
Conductor — MaterialBC - Bare Copper
Conductor — StrandingSolid
Insulation — MaterialPO - Polyolefin
Inner Jacket — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Inner Shield — MaterialBi-Laminate (Alum+Poly)
Insulation — Color CodeBlue & White with Blue Markings, Orange & White with Orange Markings, Green & White with Green Markings, Brown & White with Brown Markings
Outer Jacket — MaterialLSZH - Low Smoke Zero Halogen (Flame Retardant)
Conductor — No. Of Pairs4
Inner Shield — Shield TypeTape
Inner Jacket — Nom. Diameter9.0 mm (0.35 in)
Outer Jacket — Nom. Diameter12.3 mm (0.484 in)
Armor — Armor Type & MaterialSWA - Steel Wire Armor
Inner Shield — Drainwire Type26 AWG (Solid) TC
Insulation — Nom. Insulation Diameter1.10 mm (0.0433 in)

Standards And Compliance

Data CategoryCategory 6
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ISO/IEC ComplianceISO/IEC 11801
Environmental SuitabilityIndoor/Outdoor, Sunlight Resistance, Oil Resistance, Burial
European Directive ComplianceEU Directive 2011/65/EU (RoHS 2)
European Halogen Free StandardsIEC 60754-1 - Halogen Amount = Zero, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 μS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3, IEC 61034-2 - Smoke Density Min. Transmittance = 60%

Electrical Characteristics

Delay — Max. Delay538 ns/100m
Delay — Max. Delay Skew45 ns/100m
Voltage — Voltage Rating300 V
Electricals — Max. Conductor DCR93.8 Ohm/km (28.6 Ohm/1000ft)
High Frequency Row 1 — Min. NEXT [DB]74.3
High Frequency Row 2 — Min. NEXT [DB]65.3
High Frequency Row 3 — Min. NEXT [DB]60.8
High Frequency Row 4 — Min. NEXT [DB]59.3
High Frequency Row 5 — Min. NEXT [DB]56.2
High Frequency Row 6 — Min. NEXT [DB]54.8
High Frequency Row 7 — Min. NEXT [DB]53.3
High Frequency Row 8 — Min. NEXT [DB]51.9
High Frequency Row 9 — Min. NEXT [DB]47.4
High Frequency Row 1 — Frequency [MHz]1
High Frequency Row 10 — Min. NEXT [DB]44.3
High Frequency Row 11 — Min. NEXT [DB]41.4
High Frequency Row 12 — Min. NEXT [DB]39.8
High Frequency Row 13 — Min. NEXT [DB]38.3
High Frequency Row 2 — Frequency [MHz]4
High Frequency Row 3 — Frequency [MHz]8
High Frequency Row 4 — Frequency [MHz]10
High Frequency Row 5 — Frequency [MHz]16
High Frequency Row 6 — Frequency [MHz]20
High Frequency Row 7 — Frequency [MHz]25
High Frequency Row 8 — Frequency [MHz]31.25
High Frequency Row 9 — Frequency [MHz]62.5
High Frequency Row 1 — Min. PSNEXT [DB]72.3
High Frequency Row 10 — Frequency [MHz]100
High Frequency Row 11 — Frequency [MHz]155
High Frequency Row 12 — Frequency [MHz]200
High Frequency Row 13 — Frequency [MHz]250
High Frequency Row 2 — Min. PSNEXT [DB]63.3
High Frequency Row 3 — Min. PSNEXT [DB]58.8
High Frequency Row 4 — Min. PSNEXT [DB]57.3
High Frequency Row 5 — Min. PSNEXT [DB]54.2
High Frequency Row 6 — Min. PSNEXT [DB]52.8
High Frequency Row 7 — Min. PSNEXT [DB]51.3
High Frequency Row 8 — Min. PSNEXT [DB]49.9
High Frequency Row 9 — Min. PSNEXT [DB]45.4
Electricals — Max. Capacitance Unbalance330 pF/100m
High Frequency Row 10 — Min. PSNEXT [DB]42.3
High Frequency Row 11 — Min. PSNEXT [DB]39.4
High Frequency Row 12 — Min. PSNEXT [DB]37.8
High Frequency Row 13 — Min. PSNEXT [DB]36.3
Electricals — Nom. Characteristic Impedance100 Ohm
High Frequency Row 1 — Min. ACRF (ELFEXT) [DB]67.8
High Frequency Row 2 — Min. ACRF (ELFEXT) [DB]55.8
High Frequency Row 3 — Min. ACRF (ELFEXT) [DB]49.7
High Frequency Row 4 — Min. ACRF (ELFEXT) [DB]47.8
High Frequency Row 5 — Min. ACRF (ELFEXT) [DB]43.7
High Frequency Row 6 — Min. ACRF (ELFEXT) [DB]41.8
High Frequency Row 7 — Min. ACRF (ELFEXT) [DB]39.8
High Frequency Row 8 — Min. ACRF (ELFEXT) [DB]37.9
High Frequency Row 9 — Min. ACRF (ELFEXT) [DB]31.9
High Frequency Row 10 — Min. ACRF (ELFEXT) [DB]27.8
High Frequency Row 11 — Min. ACRF (ELFEXT) [DB]24
High Frequency Row 12 — Min. ACRF (ELFEXT) [DB]21.8
High Frequency Row 13 — Min. ACRF (ELFEXT) [DB]19.8
High Frequency Row 1 — Min. RL (Return Loss) [DB]20
High Frequency Row 2 — Min. RL (Return Loss) [DB]23
High Frequency Row 3 — Min. RL (Return Loss) [DB]24.5
High Frequency Row 4 — Min. RL (Return Loss) [DB]25
High Frequency Row 5 — Min. RL (Return Loss) [DB]25
High Frequency Row 6 — Min. RL (Return Loss) [DB]25
High Frequency Row 7 — Min. RL (Return Loss) [DB]24.3
High Frequency Row 8 — Min. RL (Return Loss) [DB]23.6
High Frequency Row 9 — Min. RL (Return Loss) [DB]21.5
High Frequency Row 1 — Min. PSACRF (PSELFEXT) [DB]64.8
High Frequency Row 10 — Min. RL (Return Loss) [DB]20.1
High Frequency Row 11 — Min. RL (Return Loss) [DB]18.8
High Frequency Row 12 — Min. RL (Return Loss) [DB]18
High Frequency Row 13 — Min. RL (Return Loss) [DB]17.3
High Frequency Row 2 — Min. PSACRF (PSELFEXT) [DB]52.8
High Frequency Row 3 — Min. PSACRF (PSELFEXT) [DB]46.7
High Frequency Row 4 — Min. PSACRF (PSELFEXT) [DB]44.8
High Frequency Row 5 — Min. PSACRF (PSELFEXT) [DB]40.7
High Frequency Row 6 — Min. PSACRF (PSELFEXT) [DB]38.8
High Frequency Row 7 — Min. PSACRF (PSELFEXT) [DB]36.8
High Frequency Row 8 — Min. PSACRF (PSELFEXT) [DB]34.9
High Frequency Row 9 — Min. PSACRF (PSELFEXT) [DB]28.9
High Frequency Row 10 — Min. PSACRF (PSELFEXT) [DB]24.8
High Frequency Row 11 — Min. PSACRF (PSELFEXT) [DB]21
High Frequency Row 12 — Min. PSACRF (PSELFEXT) [DB]18.8
High Frequency Row 13 — Min. PSACRF (PSELFEXT) [DB]16.8
High Frequency Row 1 — Max. Insertion Loss (Attenuation) [DB/100m]2
High Frequency Row 2 — Max. Insertion Loss (Attenuation) [DB/100m]3.8
High Frequency Row 3 — Max. Insertion Loss (Attenuation) [DB/100m]5.3
High Frequency Row 4 — Max. Insertion Loss (Attenuation) [DB/100m]6
High Frequency Row 5 — Max. Insertion Loss (Attenuation) [DB/100m]7.6
High Frequency Row 6 — Max. Insertion Loss (Attenuation) [DB/100m]8.5
High Frequency Row 7 — Max. Insertion Loss (Attenuation) [DB/100m]9.5
High Frequency Row 8 — Max. Insertion Loss (Attenuation) [DB/100m]10.7
High Frequency Row 9 — Max. Insertion Loss (Attenuation) [DB/100m]15.4
High Frequency Row 10 — Max. Insertion Loss (Attenuation) [DB/100m]19.8
High Frequency Row 11 — Max. Insertion Loss (Attenuation) [DB/100m]25.2
High Frequency Row 12 — Max. Insertion Loss (Attenuation) [DB/100m]29
High Frequency Row 13 — Max. Insertion Loss (Attenuation) [DB/100m]32.8

Mechanical Characteristics

Bulk Cable Weight282 kg/km (189 lbs/1000ft)
Max. Pull Tension110 N (25 lbf)
Temperature — Operating-20°C to +75°C
Bend Radius — Installation Min.98.0 mm (3.86 in)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account