
Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 3131A F2V1000.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications
- Conductor AWG: 18
- Conductor Stranding: Solid
- Conductor Material: BCCS - Bare Copper Covered Steel
- Conductor Nominal Diameter: 0.04 in
- Conductor No. of Coax: 1
- Insulation Material: PE - Polyethylene (Foam)
- Insulation Nominal Diameter: 0.18 in
Belden 3131A F2V1000 is an orderable item number in the Belden 3131A family (Cable › Fieldbus Cable › ControlNet Cable). ControlBusTM, Coax RG6 18AWG (Solid) Bare Copper Covered Steel, PO Insulation, Overall Duofoil®+ Aluminum Braid(60%)+Overall Duofoil®+Aluminum Braid(40%) Shield, PVC Outer Jacket, CMR This item: Color Gray, DEC, Put-Up Type Reel, Length 1,000 ft, UPC 612825142058. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.454 Revision Date: 02-20-2026 |
Standards
| RG Type | 6 |
| NEC Articles | Article 800 |
| CPR Euroclass | Eca |
| IEEE Compliance | 802.4 MAP, 802.7 MIni-MAP |
| NEC/(UL) Compliance | CL2R, CMR |
| CEC/C(UL) Compliance | CMG |
This Item
| UPC | 612825142058 |
| Color | Gray, DEC |
| Length | 1,000 ft |
| Item Number | 3131A F2V1000 |
| Put-Up Type | Reel |
Product Notes
| Notes | Sweep tested 5 to 400 MHz. Tap Marks Every 2.6 Meters to aid in users installation. |
Product Overview
| Suitable Applications | harsh environment, factory automation, ControlNetTM, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications |
Plenum/Non-Plenum
| Plenum (Y/N) | No |
| Plenum Number | 3132A |
Temperature Range
| UL Temperature Rating | 75°C |
| Operating Temperature Range | -30°C To +75°C |
Electrical Characteristics
| Delay — Nominal Delay | 1.2 ns/ft |
| Electrical Characteristics Notes | Tilt 5 to 10 MHz: 0.53 dB/100 M |
| Inductance — Nominal Inductance | 0.097 μH/ft |
| Other Electrical Characteristic 2 | Tilt 10 to 20 MHz: 0.89 dB/100 M |
| Other Electrical Characteristic 3 | SRL Min. 23dB (5MHz - 50MHz) |
| Phase Delay Distortion Row 1 — F/B | 0.5 |
| Phase Delay Distortion Row 2 — F/B | 1 |
| Phase Delay Distortion Row 3 — F/B | 1.5 |
| Phase Delay Distortion Row 4 — F/B | 2 |
| Phase Delay Distortion Row 5 — F/B | 2.5 |
| Conductor DCR — Outer Conductor DCR | 3.6 Ohm/1000ft |
| Conductor DCR — Nominal Conductor DCR | 28 Ohm/1000ft |
| High Frequency Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency Row 2 — Frequency [MHz] | 2 MHz |
| High Frequency Row 3 — Frequency [MHz] | 5 MHz |
| High Frequency Row 4 — Frequency [MHz] | 10 MHz |
| High Frequency Row 5 — Frequency [MHz] | 20 MHz |
| High Frequency Row 6 — Frequency [MHz] | 50 MHz |
| High Frequency Row 7 — Frequency [MHz] | 100 MHz |
| High Frequency Row 8 — Frequency [MHz] | 200 MHz |
| High Frequency Row 9 — Frequency [MHz] | 300 MHz |
| High Frequency Row 10 — Frequency [MHz] | 400 MHz |
| Conductor DCR — Nominal Outer Shield DCR | 3.6 Ohm/1000ft |
| Impedance — Nominal Characteristic Impedance | 120 Ohm |
| Impedance — Nominal Characteristic Tolerance | ± 3 Ohm |
| Phase Delay Distortion Row 1 — %PDD/100M (5MB) | -1.03 |
| Phase Delay Distortion Row 2 — %PDD/100M (5MB) | -0.3 |
| Phase Delay Distortion Row 3 — %PDD/100M (5MB) | 0 |
| Phase Delay Distortion Row 4 — %PDD/100M (5MB) | 0.2 |
| Phase Delay Distortion Row 5 — %PDD/100M (5MB) | 0.4 |
| Delay — Nominal Velocity Of Propagation (VP) [%] | 82% |
| Capacitance — Nom. Capacitance Conductor To Shield | 16.2 pF/ft |
| High Frequency (Nominal/Typical) Row 1 — Frequency [MHz] | 1 MHz |
| High Frequency (Nominal/Typical) Row 2 — Frequency [MHz] | 2 MHz |
| High Frequency (Nominal/Typical) Row 3 — Frequency [MHz] | 5 MHz |
| High Frequency (Nominal/Typical) Row 4 — Frequency [MHz] | 10 MHz |
| High Frequency (Nominal/Typical) Row 5 — Frequency [MHz] | 20 MHz |
| High Frequency (Nominal/Typical) Row 6 — Frequency [MHz] | 50 MHz |
| High Frequency (Nominal/Typical) Row 7 — Frequency [MHz] | 100 MHz |
| High Frequency (Nominal/Typical) Row 8 — Frequency [MHz] | 200 MHz |
| High Frequency (Nominal/Typical) Row 9 — Frequency [MHz] | 300 MHz |
| High Frequency Row 1 — Min. SRL (Structural Return Loss) | 23 dB |
| High Frequency (Nominal/Typical) Row 10 — Frequency [MHz] | 400 MHz |
| High Frequency (Nominal/Typical) Row 1 — Nom. Insertion Loss | 0.35 dB/100ft |
| High Frequency (Nominal/Typical) Row 2 — Nom. Insertion Loss | 0.38 dB/100ft |
| High Frequency (Nominal/Typical) Row 3 — Nom. Insertion Loss | 0.45 dB/100ft |
| High Frequency (Nominal/Typical) Row 4 — Nom. Insertion Loss | 0.59 dB/100ft |
| High Frequency (Nominal/Typical) Row 5 — Nom. Insertion Loss | 0.86 dB/100ft |
| High Frequency (Nominal/Typical) Row 6 — Nom. Insertion Loss | 1.37 dB/100ft |
| High Frequency (Nominal/Typical) Row 7 — Nom. Insertion Loss | 1.97 dB/100ft |
| High Frequency (Nominal/Typical) Row 8 — Nom. Insertion Loss | 2.82 dB/100ft |
| High Frequency (Nominal/Typical) Row 9 — Nom. Insertion Loss | 3.48 dB/100ft |
| High Frequency (Nominal/Typical) Row 10 — Nom. Insertion Loss | 4.04 dB/100ft |
Mechanical Characteristics
| Bulk Cable Weight | 33 lbs/1000ft |
| Minimum Minor Axis Bend Radius | 3 in |
| Maximum Recommended Pulling Tension | 162 lbs |
Physical Characteristics (Overall)
| Conductor Count | 1 |
| Conductor — AWG | 18 |
| Conductor — Material | BCCS - Bare Copper Covered Steel |
| Insulation Table Notes | Gas Injected |
| Conductor — Stranding | Solid |
| Insulation — Material | PE - Polyethylene (Foam) |
| Conductor — No. Of Coax | 1 |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Outer Shield Row 1 — Type | Tape |
| Outer Shield Row 2 — Type | Braid |
| Outer Shield Row 3 — Type | Tape |
| Outer Shield Row 4 — Type | Braid |
| Outer Shield Row 1 — Layer | 1 |
| Outer Shield Row 2 — Layer | 2 |
| Outer Shield Row 3 — Layer | 3 |
| Outer Shield Row 4 — Layer | 4 |
| Conductor — Nominal Diameter | 0.04 in |
| Insulation — Nominal Diameter | 0.18 in |
| Outer Shield Row 1 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 2 — Material | Aluminum |
| Outer Shield Row 3 — Material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield Row 4 — Material | Aluminum |
| Outer Jacket — Nominal Diameter | 0.301 in |
| Outer Shield Row 1 — Coverage [%] | 100% |
| Outer Shield Row 2 — Coverage [%] | 60% |
| Outer Shield Row 3 — Coverage [%] | 100% |
| Outer Shield Row 4 — Coverage [%] | 40% |
| Outer Shield Row 1 — Material Trade Name | Duofoil® |
| Outer Shield Row 3 — Material Trade Name | Duofoil® |
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1666 Riser |
| CSA Flammability | FT4 |
| UL Voltage Rating | 300 V RMS |
Applicable Environmental And Other Programs
| EU CE Mark | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS | Yes |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2011/65/EU RoHS 2) | Yes |
| EU Directive 2015/863/EU RoHS 2 Amendment) | Yes |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing