Belden Store
Belden 29722C 0102500 — VFD, 3C #12 Str BC XLPE Ins + #12 Symm. Seg. Gnd (3 of #16) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

Belden Cable

Belden|

MPN: 29722C 0102500

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29722C 0102500.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements
  • Outer Jacket Material: PVC - Polyvinyl Chloride
  • Outer Jacket Nom. Thickness: 0.063 in (1.6 mm)
  • Outer Jacket Nom. Diameter: 0.610 in (15.5 mm)
  • Outer Jacket Ripcord: Yes
  • Electricals Element: Conductor(s)
  • Electricals Nom. Conductor DCR: 1.42 Ohm/1000ft (4.66 Ohm/km)
  • Electricals Nom. Capacitance Cond-to-Cond: 40 pF/ft (130 pF/m)
Belden 29722C 0102500 is an orderable item number in the Belden 29722C family (Cable › VFD Cable). Belden Basics VFD, 3 Conductor 12AWG (7x20) Bare Copper XLPE Insulation M4 Color Code + 12AWG Symmetrical Segmented Ground (3 of 16AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant This item: Putup Type Reel, UPC 612825445456. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.87 Revision Date: 04-01-2026

This Item

UPC612825445456
Putup TypeReel
Item Number29722C 0102500

Information

Put-Up TypeReel
Update And RevisionRevision Number: 0.87 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Conductor Row 1 — Size12 AWG
Conductor Row 2 — Size16 AWG
Outer Jacket — RipcordYes
Conductor Row 1 — NotesASTM B3 Copper B8 Class B Stranding
Conductor Row 2 — NotesSegmented Grounds
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor Row 1 — ElementConductor(s)
Conductor Row 2 — ElementGround
Conductor Row 1 — MaterialBC - Bare Copper
Conductor Row 2 — MaterialBC - Bare Copper
Insulation Row 1 — ElementConductor(s)
Insulation Row 2 — ElementGround
Conductor Row 1 — Stranding7x20
Conductor Row 2 — Stranding7x24
Insulation Row 1 — MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Insulation Row 2 — MaterialNo Insulation
Outer Jacket — Nom. Diameter0.610 in (15.5 mm)
Insulation Row 1 — Color CodeBlack and Numbered
Outer Jacket — Nom. Thickness0.063 in (1.6 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — Coverage100%
Outer Shield Row 2 — MaterialBare Copper (BC)
Overall Cable Diameter (Nominal)0.610 in (15.5 mm)
Outer Shield Row 1 — Shield TypeHelical Tape
Outer Shield Row 2 — Shield TypeHelical Tape
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements3
Insulation Row 1 — Nom. Thickness0.063 in (1.6 mm)
Insulation Row 1 — Nom. Insulation Diameter0.219 in (5.56 mm)

Standards And Compliance

AWM ComplianceI/II A/B
SustainabilityCA Prop 65
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ICEA ComplianceS-95-658
NEC / UL ComplianceArticle 336, TC-ER, RHW-2
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Other Standard Compliance(s)P-07-KA070003-MSHA
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL1685 UL Loading, 1202, 383 Vertical Tray Flame Test (70,000 BTU)

Electrical Characteristics

Electricals — ElementConductor(s)
Electricals — Max. Current30 Amps per Conductor at 30oC
Voltage — UL Voltage Rating2000 V (TC), 1000 V (CSA AWM I/II A/B)
Electricals — Nom. Conductor DCR1.42 Ohm/1000ft (4.66 Ohm/km)
Electricals — Nom. Velocity Of Prop.55%
Electricals — Nom. Capacitance Cond-to-Cond40 pF/ft (130 pF/m)
Electricals — Nom. Characteristic Impedence46 Ohm
Electricals — Nom. Capacitance Cond-to-Other (Conds + Shield)72 pF/ft (240 pF/m)

Mechanical Characteristics

Bulk Cable Weight237 lbs/1000ft (353 kg/km)
Max. Pull Tension367 lbs (166 kg)
Temperature — Operating-40°C To +90°C
Temperature — UL Temperature90°C Dry, 90°C Wet
Bend Radius — Stationary Min.7.3 in (190 mm)
Bend Radius — Installation Min.7.3 in (190 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account