Belden Store
Belden 29721C 0105000 — VFD, 3C #14 Str BC XLPE Ins + #14 Symm. Seg. Gnd (3 of #18) Str BC, CTS, Blk PVC Jkt, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B

Belden Cable

Belden|

MPN: 29721C 0105000

Available on Backorder

Call for Price

Ships from and sold by A5 IT

Call for pricing

This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29721C 0105000.

224-955-1644
Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty

Key Features

  • Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements
  • Outer Jacket Material: PVC - Polyvinyl Chloride
  • Outer Jacket Nom. Thickness: 0.063 in (1.6 mm)
  • Outer Jacket Nom. Diameter: 0.566 in (14.4 mm)
  • Outer Jacket Ripcord: Yes
  • Voltage UL Voltage Rating: 2000 V (TC), 1000 V (CSA AWM I/II A/B)
  • Temperature UL Temperature: 90°C Dry, 90°C Wet
  • Temperature Operating: -40°C To +90°C
Belden 29721C 0105000 is an orderable item number in the Belden 29721C family (Cable › VFD Cable). Belden Basics VFD, 3 Conductor 14AWG (7x22) Bare Copper XLPE Insulation M4 Color Code + 14AWG Symmetrical Segmented Ground (3 of 18AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant This item: Putup Type Reel, UPC 612825445449. Ships from and sold by A5 IT. Quoted to order.

History

Update And RevisionRevision Number: 0.93 Revision Date: 04-01-2026

This Item

UPC612825445449
Putup TypeReel
Item Number29721C 0105000

Information

Put-Up TypeReel
Update And RevisionRevision Number: 0.93 Revision Date: 04-01-2026

Product Overview

Suitable ApplicationsVariable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements

Construction Details

Conductor Row 1 — Size14 AWG
Conductor Row 2 — Size18 AWG
Outer Jacket — RipcordYes
Conductor Row 1 — NotesASTM B3 Copper B8 Class B Stranding
Conductor Row 2 — NotesSegmented 14AWG Ground
Outer Jacket — MaterialPVC - Polyvinyl Chloride
Conductor Row 1 — ElementConductor(s)
Conductor Row 2 — ElementGround
Conductor Row 1 — MaterialBC - Bare Copper
Conductor Row 2 — MaterialBC - Bare Copper
Insulation Row 1 — ElementConductor(s)
Insulation Row 2 — ElementGround
Conductor Row 1 — Stranding7x22
Conductor Row 2 — Stranding7x26
Insulation Row 1 — MaterialXLPE - Cross-Linked Polyethylene (Thermoset)
Insulation Row 2 — MaterialNo Insulation
Outer Jacket — Nom. Diameter0.566 in (14.4 mm)
Insulation Row 1 — Color CodeBlack and Numbered
Outer Jacket — Nom. Thickness0.063 in (1.6 mm)
Outer Shield Row 1 — Coverage100%
Outer Shield Row 1 — MaterialBare Copper (BC)
Outer Shield Row 2 — Coverage100%
Outer Shield Row 2 — MaterialBare Copper (BC)
Overall Cable Diameter (Nominal)0.566 in (14.4 mm)
Outer Shield Row 1 — Shield TypeHelical Tape
Outer Shield Row 2 — Shield TypeHelical Tape
Conductor Row 1 — No. Of Elements3
Conductor Row 2 — No. Of Elements3
Insulation Row 1 — Nom. Thickness0.063 in (1.6 mm)
Insulation Row 1 — Nom. Insulation Diameter0.197 in (5.00 mm)

Standards And Compliance

AWM ComplianceI/II A/B
SustainabilityCA Prop 65
APAC ComplianceChina RoHS II (GB/T 26572-2011)
ICEA ComplianceS-95-658
NEC / UL ComplianceArticle 336, TC-ER, RHW-2
Environmental SuitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Other Standard Compliance(s)P-07-KA070003-MSHA
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
Flammability / Reaction To FireUL1685 UL Loading, 1202, 383 Vertical Tray Flame Test (70,000 BTU)

Electrical Characteristics

Electricals Row 1 — ElementConductor(s)
Voltage — UL Voltage Rating2000 V (TC), 1000 V (CSA AWM I/II A/B)
Electricals Row 1 — Max. Current25 Amps per Conductor at 30oC
Electricals Row 1 — Nom. Conductor DCR2.253 Ohm/1000ft (7.392 Ohm/km)
Electricals Row 2 — Nom. Conductor DCR1.4 Ohm/1000ft (4.6 Ohm/km)
Electricals Row 1 — Nom. Velocity Of Prop.55%
Electricals Row 1 — Nom. Capacitance Cond-to-Cond21 pF/ft (69 pF/m)
Electricals Row 1 — Nom. Characteristic Impedence90 Ohm
Electricals Row 1 — Nom. Capacitance Cond-to-Shield38 pF/ft (120 pF/m)
Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield)38 pF/ft (120 pF/m)

Mechanical Characteristics

Bulk Cable Weight185 lbs/1000ft (275 kg/km)
Max. Pull Tension231 lbs (105 kg)
Temperature — Operating-40°C To +90°C
Temperature — UL Temperature90°C Dry, 90°C Wet
Bend Radius — Stationary Min.6.8 in (170 mm)
Bend Radius — Installation Min.6.8 in (170 mm)

Purchasing this for your business?

Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.

Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support
Priority order processing
Create Free Business Account