Belden Cable
Call for Price
Ships from and sold by A5 IT
Call for pricing
This part is quoted to order. Call for current pricing, lead time and volume breaks on the Belden 29721C 0102500.
224-955-1644Free 2-3 Day Shipping within the United StatesShips as soon as stock arrives. We'll confirm the lead time before your card is charged.
New, with full manufacturer warranty
Key Features
- Suitable Applications: Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements
- Outer Jacket Material: PVC - Polyvinyl Chloride
- Outer Jacket Nom. Thickness: 0.063 in (1.6 mm)
- Outer Jacket Nom. Diameter: 0.566 in (14.4 mm)
- Outer Jacket Ripcord: Yes
- Voltage UL Voltage Rating: 2000 V (TC), 1000 V (CSA AWM I/II A/B)
- Temperature UL Temperature: 90°C Dry, 90°C Wet
- Temperature Operating: -40°C To +90°C
Belden 29721C 0102500 is an orderable item number in the Belden 29721C family (Cable › VFD Cable). Belden Basics VFD, 3 Conductor 14AWG (7x22) Bare Copper XLPE Insulation M4 Color Code + 14AWG Symmetrical Segmented Ground (3 of 18AWG) Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 90C Dry/Wet 1000V CSA AWM I/II A/B SUN RES DIR BUR Oil Resistant This item: Putup Type Reel, UPC 612825445432. Ships from and sold by A5 IT. Quoted to order.
History
| Update And Revision | Revision Number: 0.93 Revision Date: 04-01-2026 |
This Item
| UPC | 612825445432 |
| Putup Type | Reel |
| Item Number | 29721C 0102500 |
Information
| Put-Up Type | Reel |
| Update And Revision | Revision Number: 0.93 Revision Date: 04-01-2026 |
Product Overview
| Suitable Applications | Variable Frequency Drives (VFD); AC Motor and Drive Systems; High voltage requirements |
Construction Details
| Conductor Row 1 — Size | 14 AWG |
| Conductor Row 2 — Size | 18 AWG |
| Outer Jacket — Ripcord | Yes |
| Conductor Row 1 — Notes | ASTM B3 Copper B8 Class B Stranding |
| Conductor Row 2 — Notes | Segmented 14AWG Ground |
| Outer Jacket — Material | PVC - Polyvinyl Chloride |
| Conductor Row 1 — Element | Conductor(s) |
| Conductor Row 2 — Element | Ground |
| Conductor Row 1 — Material | BC - Bare Copper |
| Conductor Row 2 — Material | BC - Bare Copper |
| Insulation Row 1 — Element | Conductor(s) |
| Insulation Row 2 — Element | Ground |
| Conductor Row 1 — Stranding | 7x22 |
| Conductor Row 2 — Stranding | 7x26 |
| Insulation Row 1 — Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Insulation Row 2 — Material | No Insulation |
| Outer Jacket — Nom. Diameter | 0.566 in (14.4 mm) |
| Insulation Row 1 — Color Code | Black and Numbered |
| Outer Jacket — Nom. Thickness | 0.063 in (1.6 mm) |
| Outer Shield Row 1 — Coverage | 100% |
| Outer Shield Row 1 — Material | Bare Copper (BC) |
| Outer Shield Row 2 — Coverage | 100% |
| Outer Shield Row 2 — Material | Bare Copper (BC) |
| Overall Cable Diameter (Nominal) | 0.566 in (14.4 mm) |
| Outer Shield Row 1 — Shield Type | Helical Tape |
| Outer Shield Row 2 — Shield Type | Helical Tape |
| Conductor Row 1 — No. Of Elements | 3 |
| Conductor Row 2 — No. Of Elements | 3 |
| Insulation Row 1 — Nom. Thickness | 0.063 in (1.6 mm) |
| Insulation Row 1 — Nom. Insulation Diameter | 0.197 in (5.00 mm) |
Standards And Compliance
| AWM Compliance | I/II A/B |
| Sustainability | CA Prop 65 |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| ICEA Compliance | S-95-658 |
| NEC / UL Compliance | Article 336, TC-ER, RHW-2 |
| Environmental Suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial |
| Other Standard Compliance(s) | P-07-KA070003-MSHA |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Flammability / Reaction To Fire | UL1685 UL Loading, 1202, 383 Vertical Tray Flame Test (70,000 BTU) |
Electrical Characteristics
| Electricals Row 1 — Element | Conductor(s) |
| Voltage — UL Voltage Rating | 2000 V (TC), 1000 V (CSA AWM I/II A/B) |
| Electricals Row 1 — Max. Current | 25 Amps per Conductor at 30oC |
| Electricals Row 1 — Nom. Conductor DCR | 2.253 Ohm/1000ft (7.392 Ohm/km) |
| Electricals Row 2 — Nom. Conductor DCR | 1.4 Ohm/1000ft (4.6 Ohm/km) |
| Electricals Row 1 — Nom. Velocity Of Prop. | 55% |
| Electricals Row 1 — Nom. Capacitance Cond-to-Cond | 21 pF/ft (69 pF/m) |
| Electricals Row 1 — Nom. Characteristic Impedence | 90 Ohm |
| Electricals Row 1 — Nom. Capacitance Cond-to-Shield | 38 pF/ft (120 pF/m) |
| Electricals Row 1 — Nom. Capacitance Cond-to-Other (Conds + Shield) | 38 pF/ft (120 pF/m) |
Mechanical Characteristics
| Bulk Cable Weight | 185 lbs/1000ft (275 kg/km) |
| Max. Pull Tension | 231 lbs (105 kg) |
| Temperature — Operating | -40°C To +90°C |
| Temperature — UL Temperature | 90°C Dry, 90°C Wet |
| Bend Radius — Stationary Min. | 6.8 in (170 mm) |
| Bend Radius — Installation Min. | 6.8 in (170 mm) |
Purchasing this for your business?
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Wholesale pricing below retail
Net-30 terms for qualified businesses
Volume discount tiers
Dedicated account representative
Saved payment methods & PO support